1,115 research outputs found

    Sviluppo del miocardio fetale: impatto dell'orientamento delle fibre sulla funzione diastolica del ventricolo sinistro

    Get PDF
    Background: Left ventricular myocardium is arranged in a complex three-dimensional network of fibers, which form a counterclockwise helix in the endocardial layer and a clockwise helix in the epicardial layer. This architecture may change in congenital and acquired heart disease. However, few studies evaluated the fetal myocardial development as well as the mechanism promoting these changes. Purpose of the study: Speckle Tracking Echocardiography allows to study endocardial and epicardial functionality in vivo separately. Combining these data with morphometric observations on histological sections of fetal human heart, we compared the development of the different myocardial layers with advancing gestational age. In addition, we verified in-silico the influence of different myocardial fibers arrangements on diastolic performance. Methods: To study fetal myocardial function, we enrolled 72 fetuses and 39 premature babies without cardiac pathologies. We studied longitudinal endocardial and epicardial strain in these patients. For the histological section, we studied 20 fetal hearts without cardiac pathologies from autopsy investigation. We determined every layer’s thickness and cardiac fibers orientation in comparison with gestational age. Concerning the in-silico study, three finite element models of the left ventricular myocardium were developed, corresponding to 20, 30 and 40 weeks’ fetuses. An idealized thick walled ellipsoidal shape was considered, based on the values obtained from fetuses and babies measurements. Different combinations for the fiber orientations were investigated. Results: Endocardial values of deformation are higher than epicardial ones. Epi/endocardial values ratio increased with gestational age (R=0.51, p<0.0001). Histological data confirm these observations (Epi/Endocardial thickness ratio over the gestational age: R=0.76; P<0.0001). All layers increase their thickness during but, while epicardium increases fourfold, trabecular and endocardial layers maintain almost the same value throughout pregnancy. Computational models showed that a radial arrangement of the myocardial fibers gives the highest diastolic compliance, while a longitudinal arrangement gives the poorest diastolic compliance. The endocardial longitudinal layer is the main contributor to the left ventricular diastolic rigidity. Conclusions: Left ventricular myocardium maturation is a process that begins early during fetal life. It starts from the differentiation of a subendocardial layer. The development of the epicardium is slower than the endocardium and it is completed late in the fetal life. The radial arrangement of the myocardium fibers gives the highest compliance to the left ventricle, with poor changes in end-diastolic pressure even getting twice the end-diastolic volume. The endocardial longitudinal fibers are the main contributors to the preservation of the shape of the left ventricle

    Implantation of atrial flow regulator devices in patients with congenital heart disease and children with severe pulmonary hypertension or cardiomyopathy—an international multicenter case series

    Get PDF
    Fontan circulation; Atrial flow regulator device; Congenital heart diseaseCirculació de Fontan; Dispositiu regulador de flux auricular; Malaltia cardíaca congènitaCirculación de Fontan; Dispositivo regulador de flujo auricular; Enfermedad cardíaca congénitaBackground: The Occlutech Atrial Flow Regulator (AFR) is a self-expandable double-disc nitinol device with a central fenestration. Its use has been approved in the adult population with heart failure and described for pulmonary hypertension (PH). Only case reports and small series have been published about its use in the paediatric population and for congenital heart disease (CHD). Objectives: The authors sought to investigate the feasibility, safety, and short-term follow-up of AFR implantation in patients with CHD or children with PH or cardiomyopathy. Methods: This is a multicenter retrospective study involving 10 centers worldwide. Patients of any age with CHD or patients aged < 18 years with PH or cardiomyopathy needing AFR implantation were included. Results: A total of 40 patients underwent AFR implantation. The median age of the population at the time of the procedure was 58.5 months (IQR: 31.5–142.5) and the median weight was 17 kg (IQR: 10–46). A total of 26 (65.0%) patients had CHD, nine (22.5%) children, a cardiomyopathy, and five (12.5%), a structurally normal heart. The implantation success rate was 100%. There were two early and one late device thrombosis. Two patients (5.0%) with dilated cardiomyopathy on extracorporeal membrane oxygenator (ECMO) died during the hospital stay. At a median follow-up of 330 days (IQR: 125–593), 37 (92.5%) patients were alive. At follow-up, 20 patients improved their New York Heart Association (NYHA) class, 12 patients did not change their NYHA class, and one patient with idiopathic PH worsened. Conclusions: AFR implantation in patients with CHD and children with severe PH or cardiomyopathy is promising and seems to have beneficial effects at short-term follow-up.EP, is funded by the European Commission through the Horizon 2020 Marie Ska, odowska-Curie Actions programme under Grant number 956394 within the PremAtuRe nEwborn motor and cogNitive impairmenTs: Early diagnosis (PARENT) project. This work was supported also by the Italian Ministry of Health with Current Research funds

    Resilience and response of the congenital cardiac network in Italy during the COVID-19 pandemic

    Get PDF
    : The worldwide response to the current COVID-19 pandemic has been focused on how to prevent the disease and to protect the high-risk patient from a potentially lethal infection. Several consensus and guidelines articles have been published dealing with the cardiac patient with systemic hypertension, heart transplant or heart failure. Very little is known about the patients, both in the pediatric as well as in the adult age, with congenital heart disease. The peculiar physiology of the heart with a native, repaired or palliated congenital heart defect deserves a specialized care. Hereby we describe the early recommendations issued by the Italian Society of Pediatric Cardiology and Congenital Heart Disease and how the network of the congenital cardiac institutions in Italy reacted to the threat of potential wide spread of the infection among this fragile kind of patient

    Implantation of atrial flow regulator devices in patients with congenital heart disease and children with severe pulmonary hypertension or cardiomyopathy—an international multicenter case series

    Get PDF
    BackgroundThe Occlutech Atrial Flow Regulator (AFR) is a self-expandable double-disc nitinol device with a central fenestration. Its use has been approved in the adult population with heart failure and described for pulmonary hypertension (PH). Only case reports and small series have been published about its use in the paediatric population and for congenital heart disease (CHD).ObjectivesThe authors sought to investigate the feasibility, safety, and short-term follow-up of AFR implantation in patients with CHD or children with PH or cardiomyopathy.MethodsThis is a multicenter retrospective study involving 10 centers worldwide. Patients of any age with CHD or patients aged &lt; 18 years with PH or cardiomyopathy needing AFR implantation were included.ResultsA total of 40 patients underwent AFR implantation. The median age of the population at the time of the procedure was 58.5 months (IQR: 31.5–142.5) and the median weight was 17 kg (IQR: 10–46). A total of 26 (65.0%) patients had CHD, nine (22.5%) children, a cardiomyopathy, and five (12.5%), a structurally normal heart. The implantation success rate was 100%. There were two early and one late device thrombosis. Two patients (5.0%) with dilated cardiomyopathy on extracorporeal membrane oxygenator (ECMO) died during the hospital stay. At a median follow-up of 330 days (IQR: 125–593), 37 (92.5%) patients were alive. At follow-up, 20 patients improved their New York Heart Association (NYHA) class, 12 patients did not change their NYHA class, and one patient with idiopathic PH worsened.ConclusionsAFR implantation in patients with CHD and children with severe PH or cardiomyopathy is promising and seems to have beneficial effects at short-term follow-up

    Global disparities in surgeons’ workloads, academic engagement and rest periods: the on-calL shIft fOr geNEral SurgeonS (LIONESS) study

    Get PDF
    : The workload of general surgeons is multifaceted, encompassing not only surgical procedures but also a myriad of other responsibilities. From April to May 2023, we conducted a CHERRIES-compliant internet-based survey analyzing clinical practice, academic engagement, and post-on-call rest. The questionnaire featured six sections with 35 questions. Statistical analysis used Chi-square tests, ANOVA, and logistic regression (SPSS® v. 28). The survey received a total of 1.046 responses (65.4%). Over 78.0% of responders came from Europe, 65.1% came from a general surgery unit; 92.8% of European and 87.5% of North American respondents were involved in research, compared to 71.7% in Africa. Europe led in publishing research studies (6.6 ± 8.6 yearly). Teaching involvement was high in North America (100%) and Africa (91.7%). Surgeons reported an average of 6.7 ± 4.9 on-call shifts per month, with European and North American surgeons experiencing 6.5 ± 4.9 and 7.8 ± 4.1 on-calls monthly, respectively. African surgeons had the highest on-call frequency (8.7 ± 6.1). Post-on-call, only 35.1% of respondents received a day off. Europeans were most likely (40%) to have a day off, while African surgeons were least likely (6.7%). On the adjusted multivariable analysis HDI (Human Development Index) (aOR 1.993) hospital capacity &gt; 400 beds (aOR 2.423), working in a specialty surgery unit (aOR 2.087), and making the on-call in-house (aOR 5.446), significantly predicted the likelihood of having a day off after an on-call shift. Our study revealed critical insights into the disparities in workload, access to research, and professional opportunities for surgeons across different continents, underscored by the HDI

    Measurement of the top quark forward-backward production asymmetry and the anomalous chromoelectric and chromomagnetic moments in pp collisions at √s = 13 TeV

    Get PDF
    Abstract The parton-level top quark (t) forward-backward asymmetry and the anomalous chromoelectric (d̂ t) and chromomagnetic (μ̂ t) moments have been measured using LHC pp collisions at a center-of-mass energy of 13 TeV, collected in the CMS detector in a data sample corresponding to an integrated luminosity of 35.9 fb−1. The linearized variable AFB(1) is used to approximate the asymmetry. Candidate t t ¯ events decaying to a muon or electron and jets in final states with low and high Lorentz boosts are selected and reconstructed using a fit of the kinematic distributions of the decay products to those expected for t t ¯ final states. The values found for the parameters are AFB(1)=0.048−0.087+0.095(stat)−0.029+0.020(syst),μ̂t=−0.024−0.009+0.013(stat)−0.011+0.016(syst), and a limit is placed on the magnitude of | d̂ t| &lt; 0.03 at 95% confidence level. [Figure not available: see fulltext.

    MUSiC : a model-unspecific search for new physics in proton-proton collisions at root s=13TeV

    Get PDF
    Results of the Model Unspecific Search in CMS (MUSiC), using proton-proton collision data recorded at the LHC at a centre-of-mass energy of 13 TeV, corresponding to an integrated luminosity of 35.9 fb(-1), are presented. The MUSiC analysis searches for anomalies that could be signatures of physics beyond the standard model. The analysis is based on the comparison of observed data with the standard model prediction, as determined from simulation, in several hundred final states and multiple kinematic distributions. Events containing at least one electron or muon are classified based on their final state topology, and an automated search algorithm surveys the observed data for deviations from the prediction. The sensitivity of the search is validated using multiple methods. No significant deviations from the predictions have been observed. For a wide range of final state topologies, agreement is found between the data and the standard model simulation. This analysis complements dedicated search analyses by significantly expanding the range of final states covered using a model independent approach with the largest data set to date to probe phase space regions beyond the reach of previous general searches.Peer reviewe

    Search for new particles in events with energetic jets and large missing transverse momentum in proton-proton collisions at root s=13 TeV

    Get PDF
    A search is presented for new particles produced at the LHC in proton-proton collisions at root s = 13 TeV, using events with energetic jets and large missing transverse momentum. The analysis is based on a data sample corresponding to an integrated luminosity of 101 fb(-1), collected in 2017-2018 with the CMS detector. Machine learning techniques are used to define separate categories for events with narrow jets from initial-state radiation and events with large-radius jets consistent with a hadronic decay of a W or Z boson. A statistical combination is made with an earlier search based on a data sample of 36 fb(-1), collected in 2016. No significant excess of events is observed with respect to the standard model background expectation determined from control samples in data. The results are interpreted in terms of limits on the branching fraction of an invisible decay of the Higgs boson, as well as constraints on simplified models of dark matter, on first-generation scalar leptoquarks decaying to quarks and neutrinos, and on models with large extra dimensions. Several of the new limits, specifically for spin-1 dark matter mediators, pseudoscalar mediators, colored mediators, and leptoquarks, are the most restrictive to date.Peer reviewe

    Measurement of prompt open-charm production cross sections in proton-proton collisions at root s=13 TeV

    Get PDF
    The production cross sections for prompt open-charm mesons in proton-proton collisions at a center-of-mass energy of 13TeV are reported. The measurement is performed using a data sample collected by the CMS experiment corresponding to an integrated luminosity of 29 nb(-1). The differential production cross sections of the D*(+/-), D-+/-, and D-0 ((D) over bar (0)) mesons are presented in ranges of transverse momentum and pseudorapidity 4 < p(T) < 100 GeV and vertical bar eta vertical bar < 2.1, respectively. The results are compared to several theoretical calculations and to previous measurements.Peer reviewe

    Combined searches for the production of supersymmetric top quark partners in proton-proton collisions at root s=13 TeV

    Get PDF
    A combination of searches for top squark pair production using proton-proton collision data at a center-of-mass energy of 13 TeV at the CERN LHC, corresponding to an integrated luminosity of 137 fb(-1) collected by the CMS experiment, is presented. Signatures with at least 2 jets and large missing transverse momentum are categorized into events with 0, 1, or 2 leptons. New results for regions of parameter space where the kinematical properties of top squark pair production and top quark pair production are very similar are presented. Depending on themodel, the combined result excludes a top squarkmass up to 1325 GeV for amassless neutralino, and a neutralinomass up to 700 GeV for a top squarkmass of 1150 GeV. Top squarks with masses from 145 to 295 GeV, for neutralino masses from 0 to 100 GeV, with a mass difference between the top squark and the neutralino in a window of 30 GeV around the mass of the top quark, are excluded for the first time with CMS data. The results of theses searches are also interpreted in an alternative signal model of dark matter production via a spin-0 mediator in association with a top quark pair. Upper limits are set on the cross section for mediator particle masses of up to 420 GeV
    corecore