567 research outputs found

    Asymptotic Analysis of Thin Interface in Composite Materials with Coated Boundary

    Get PDF
    This paper considers the problem of thin interface in a fibre reinforced composite material. Using the singular asymptotic procedure, the authors obtain simplified relations known as spring model. Phenomenon of edge effect is also studied using the Papkovich-Fadle approach. The singularities of the limit problem are analysed

    Wave propagation in periodic composites: higher-order asymptotic analysis versus plane-wave expansion method

    Get PDF
    This work is devoted to a comparison of different methods determining stop-bands i

    Anticholinergic medications in patients admitted with cognitive impairment or falls (AMiCI). The impact of hospital admission on anticholinergic cognitive medication burden. Results of a multicentre observational study

    Get PDF
    What is known and objectiveDrugs with anticholinergic properties increase the risk of falls, delirium, chronic cognitive impairment, and mortality and counteract procholinergic medications used in the treatment of dementia. Medication review and optimisation to reduce anticholinergic burden in patients at risk is recommended by specialist bodies. Little is known how effective this review is in patients who present acutely and how often drugs with anticholinergic properties are used temporarily during an admission. The aim of the study was to describe the changes in the anticholinergic cognitive burden (ACB) in patients admitted to hospital with a diagnosis of delirium, chronic cognitive impairment or falls and to look at the temporary use of anticholinergic medications during hospital stay. MethodsThis is a multi-centre observational study that was conducted in seven different hospitals in the UK, Finland, The Netherlands and Italy. Results and discussion21.1% of patients had their ACB score reduced by a mean of 1.7%, 19.7% had their ACB increased by a mean of 1.6%, 22.8% of DAP naive patients were discharged on anticholinergic medications. There was no change in the ACB scores in 59.2% of patients. 54.1% of patients on procholinergics were taking anticholinergics. Out of the 98 medications on the ACB scale, only 56 were seen. Medications with a low individual burden were accounting for 64.9% of the total burden. Anticholinergic drugs were used temporarily during the admission in 21.9% of all patients. A higher number of DAPs used temporarily during admission was associated with a higher risk of ACB score increase on discharge (OR=1.82, 95% CI for OR: 1.36-2.45, P What is new and conclusionThere was no reduction in anticholinergic cognitive burden during the acute admissions. This was the same for all diagnostic subgroups. The anticholinergic load was predominantly caused by medications with a low individual burden. More than 1 in 5 patients not taking anticholinergics on admission were discharged on them and similar numbers saw temporary use of these medications during their admission. More than half of patients on cholinesterase-inhibitors were taking anticholinergics at the same time on admission, potentially directly counteracting their effects.Peer reviewe

    Micro-CT Based Experimental Liver Imaging Using a Nanoparticulate Contrast Agent: A Longitudinal Study in Mice

    Get PDF
    BACKGROUND: Micro-CT imaging of liver disease in mice relies on high soft tissue contrast to detect small lesions like liver metastases. Purpose of this study was to characterize the localization and time course of contrast enhancement of a nanoparticular alkaline earth metal-based contrast agent (VISCOVER ExiTron nano) developed for small animal liver CT imaging. METHODOLOGY: ExiTron nano 6000 and ExiTron nano 12000, formulated for liver/spleen imaging and angiography, respectively, were intravenously injected in C57BL/6J-mice. The distribution and time course of contrast enhancement were analysed by repeated micro-CT up to 6 months. Finally, mice developing liver metastases after intrasplenic injection of colon carcinoma cells underwent longitudinal micro-CT imaging after a single injection of ExiTron nano. PRINCIPAL FINDINGS: After a single injection of ExiTron nano the contrast of liver and spleen peaked after 4-8 hours, lasted up to several months and was tolerated well by all mice. In addition, strong contrast enhancement of abdominal and mediastinal lymph nodes and the adrenal glands was observed. Within the first two hours after injection, particularly ExiTron nano 12000 provided pronounced contrast for imaging of vascular structures. ExiTron nano facilitated detection of liver metastases and provided sufficient contrast for longitudinal observation of tumor development over weeks. CONCLUSIONS: The nanoparticulate contrast agents ExiTron nano 6000 and 12000 provide strong contrast of the liver, spleen, lymph nodes and adrenal glands up to weeks, hereby allowing longitudinal monitoring of pathological processes of these organs in small animals, with ExiTron nano 12000 being particularly optimized for angiography due to its very high initial vessel contrast

    Histone deacetylases as new therapy targets for platinum-resistant epithelial ovarian cancer

    Get PDF
    Introduction: In developed countries, ovarian cancer is the fourth most common cancer in women. Due to the nonspecific symptomatology associated with the disease many patients with ovarian cancer are diagnosed late, which leads to significantly poorer prognosis. Apart from surgery and radiotherapy, a substantial number of ovarian cancer patients will undergo chemotherapy and platinum based agents are the mainstream first-line therapy for this disease. Despite the initial efficacy of these therapies, many women relapse; therefore, strategies for second-line therapies are required. Regulation of DNA transcription is crucial for tumour progression, metastasis and chemoresistance which offers potential for novel drug targets. Methods: We have reviewed the existing literature on the role of histone deacetylases, nuclear enzymes regulating gene transcription. Results and conclusion: Analysis of available data suggests that a signifant proportion of drug resistance stems from abberant gene expression, therefore HDAC inhibitors are amongst the most promising therapeutic targets for cancer treatment. Together with genetic testing, they may have a potential to serve as base for patient-adapted therapies

    Journal Staff

    Get PDF
    We present the first measurements of the differential cross section d sigma/dp(T)(gamma) for the production of an isolated photon in association with at least two b-quark jets. The measurements consider photons with rapidities vertical bar y(gamma)vertical bar < 1.0 and transverse momenta 30 < p(T)(gamma) < 200 GeV. The b-quark jets are required to have p(T)(jet) > 15 GeVand vertical bar y(jet)vertical bar < 1.5. The ratio of differential production cross sections for gamma + 2 b-jets to gamma + b-jet as a function of p(T)(gamma) is also presented. The results are based on the proton-antiproton collision data at root s = 1.96 TeV collected with the D0 detector at the Fermilab Tevatron Collider. The measured cross sections and their ratios are compared to the next- to- leading order perturbative QCD calculations as well as predictions based on the k(T)- factorization approach and those from the sherpa and pythia Monte Carlo event generators

    Measurement of the top quark mass using the matrix element technique in dilepton final states

    Get PDF
    We present a measurement of the top quark mass in pp¯ collisions at a center-of-mass energy of 1.96 TeV at the Fermilab Tevatron collider. The data were collected by the D0 experiment corresponding to an integrated luminosity of 9.7  fb−1. The matrix element technique is applied to tt¯ events in the final state containing leptons (electrons or muons) with high transverse momenta and at least two jets. The calibration of the jet energy scale determined in the lepton+jets final state of tt¯ decays is applied to jet energies. This correction provides a substantial reduction in systematic uncertainties. We obtain a top quark mass of mt=173.93±1.84  GeV

    Measurement of Leptonic Asymmetries and Top Quark Polarization in ttbar Production

    Get PDF
    We present measurements of lepton (l) angular distributions in ttbar -> W+ b W- b -> l+ nu b l- nubar bbar decays produced in ppbar collisions at a center-of-mass energy of sqrt(s)=1.96TeV, where l is an electron or muon. Using data corresponding to an integrated luminosity of 5.4fb^-1, collected with the D0 detector at the Fermilab Collider, we find that the angular distributions of l- relative to anti-protons and l+ relative to protons are in agreement with each other. Combining the two distributions and correcting for detector acceptance we obtain the forward-backward asymmetry A^l_FB = (5.8 +- 5.1(stat) +- 1.3(syst))%, compared to the standard model prediction of A^l_FB (predicted) = (4.7 +- 0.1)%. This result is further combined with the measurement based on the analysis of the l+jets final state to obtain A^l_FB = (11.8 +- 3.2)%. Furthermore, we present a first study of the top-quark polarization.Comment: submitted versio

    Measurement of the semileptonic charge asymmetry in B0 meson mixing with the D0 detector

    Get PDF
    We present a measurement of the semileptonic mixing asymmetry for B0 mesons, a^d_{sl}, using two independent decay channels: B0 -> mu+D-X, with D- -> K+pi-pi-; and B0 -> mu+D*-X, with D*- -> antiD0 pi-, antiD0 -> K+pi- (and charge conjugate processes). We use a data sample corresponding to 10.4 fb^{-1} of ppbar collisions at sqrt(s) = 1.96 TeV, collected with the D0 experiment at the Fermilab Tevatron collider. We extract the charge asymmetries in these two channels as a function of the visible proper decay length (VPDL) of the B0 meson, correct for detector-related asymmetries using data-driven methods, and account for dilution from charge-symmetric processes using Monte Carlo simulation. The final measurement combines four signal VPDL regions for each channel, yielding a^d_{sl} = [0.68 \pm 0.45 \text{(stat.)} \pm 0.14 \text{(syst.)}]%. This is the single most precise measurement of this parameter, with uncertainties smaller than the current world average of B factory measurements.Comment: Version includes minor textual changes following peer review by journal, most notably the updating of Ref. [21] to reflect the most recent publicatio

    Search for B0π0π0B^{0}\to \pi^{0}\pi^{0} Decay

    Get PDF
    We have searched for the charmless hadronic decay of B0 mesons into two neutral pions. Using 9.13fb^-1 taken at the Upsilon(4S) with the CLEO detector, we obtain an improved upper limit for the branching fraction BR(B0-->pi0pi0) < 5.7*10^-6 at the 90% confidence level.Comment: pages postscript, also available through http://w4.lns.cornell.edu/public/CLN
    corecore