567 research outputs found
hydrogen embrittlement in advanced high strength steels and ultra high strength steels a new investigation approach
Abstract In order to reduce CO2 emissions and fuel consumption, and to respect current environmental norms, the reduction of vehicles weight is a primary target of the automotive industry. Advanced High Strength Steels (AHSS) and Ultra High Strength Steel (UHSS), which present excellent mechanical properties, are consequently increasingly used in vehicle manufacturing. The increased strength to mass ratio compensates the higher cost per kg, and AHSS and UHSS are proving to be cost-effective solutions for the body-in-white of mass market products. In particular, aluminized boron steel can be formed in complex shapes with press hardening processes, acquiring high strength without distortion, and increasing protection from crashes. On the other hand, its characteristic martensitic microstructure is sensitive to hydrogen delayed fracture phenomena and, at the same time, the dew point in the furnace can produce hydrogen consequently to the high temperature reaction between water and aluminum. The high temperature also promotes hydrogen diffusion through the metal lattice under the aluminum-silicon coating, thus increasing the diffusible hydrogen content. However, after cooling, the coating acts as a strong barrier preventing the hydrogen from going out of the microstructure. This increases the probability of delayed fracture. As this failure brings to the rejection of the component during production, or, even worse, to the failure in its operation, diffusible hydrogen absorbed in the component needs to be monitored during the production process. For fast and simple measurements of the response to diffusible hydrogen of aluminized boron steel, one of the HELIOS innovative instruments was used, HELIOS II. Unlike the Devanathan cell that is based on a double electrochemical cell, HELIOS II is based on a single cell coupled with a solid-state sensor. The instrument is able to give an immediate measure of diffusible hydrogen content in sheet steels, semi-products or products, avoiding time-consuming specimen palladium coating with a guided procedure that requires virtually zero training. Two examples of diffusible hydrogen analyses are given for Usibor®1500-AS, one before hot stamping/ quenching, and one after hot stamping, suggesting that the increase in the number of dislocations during hot stamping could be the main responsible for the lower apparent diffusivity of hydrogen
Design of a non-destructive test for validating models of hydrogen migration.
High-strength steels, despite their excellent mechanical properties in normal conditions, can be susceptible to hydrogen embrittlement. Due to the service loads or residual stresses, hydrogen migrates within the component and accumulates in the regions where the highest tensile hydrostatic stress occurs. As a consequence, component brittle failure can occur even if the initial or mean hydrogen concentration is lower than the critical value. The availability of models predicting the hydrogen diffusion within the component is a crucial task for the design. Several diffusive models have been presented in the literature and some general-purpose finite element codes have implemented some of them. However, the validation of those models is still an open issue due to the difficulty in performing accurate local measurements of the hydrogen concentration. This study deals with the design of a test potentially able to validate hydrogen migration models. In the test, a four-point bending configuration is applied to a properly shaped hourglass specimen, previously charged with hydrogen, extracted from thin high-strength steel sheets. The specimen geometry and the loading configuration were designed to obtain a central region in which the stress and strain field is uniform in plane and exhibits a quasi-uniform gradient in the thickness direction. As a consequence, it is expected a large enough central region of the specimen in which the Hydrogen can migrate only in the thickness direction during the typical duration of the test. The local hydrogen concentration is evaluated by measuring the flux leaving the tensile surface of the specimen by a solid-state hydrogen sensor
Time domain diffuse Raman spectroscopy using single pixel detection
: Diffuse Raman spectroscopy (DIRS) extends the high chemical specificity of Raman scattering to in-depth investigation of thick biological tissues. We present here a novel approach for time-domain diffuse Raman spectroscopy (TD-DIRS) based on a single-pixel detector and a digital micromirror device (DMD) within an imaging spectrometer for wavelength encoding. This overcomes the intrinsic complexity and high cost of detection arrays with ps-resolving time capability. Unlike spatially offset Raman spectroscopy (SORS) or frequency offset Raman spectroscopy (FORS), TD-DIRS exploits the time-of-flight distribution of photons to probe the depth of the Raman signal at a single wavelength with a single source-detector separation. We validated the system using a bilayer tissue-bone mimicking phantom composed of a 1 cm thick slab of silicone overlaying a calcium carbonate specimen and demonstrated a high differentiation of the two Raman signals. We reconstructed the Raman spectra of the two layers, offering the potential for improved and quantitative material analysis. Using a bilayer phantom made of porcine muscle and calcium carbonate, we proved that our system can retrieve Raman peaks even in the presence of autofluorescence typical of biomedical tissues. Overall, our novel TD-DIRS setup proposes a cost-effective and high-performance approach for in-depth Raman spectroscopy in diffusive media
DUAL-PHASE STEEL REINFORCING BARS FOR MRFS STRUCTURES IN SEISMIC PRONE AREAS
Reinforced concrete structures in seismic areas are designed according to the capacity design approach, aiming to achieve ductile global collapse mechanisms dissipating the seismic energy through high deformations in correspondence of the ends of beams and columns. The global dissipative capacity of the building is related to the rotational capacity of sections and to the ductile properties of reinforcing bars. TempCore steel is used for RC constructions, due to its optimal strength and ductility properties and to the satisfaction of Eurocode 8 requirements concerning Agt and Rm/Re. Several studies in the current scientific literature anyway highlighted durability problems of TempCore bars exposed to corrosion conditions, with loss of ductility and strength even below the standards requirements. Dual-Phase (DP) steels, characterized by excellent mechanical and durability properties due to their Ferrite-Martensite microstructure and commonly adopted in the automotive sector, can be a possible solution to the problem. The possibility to produce DP rebars for RC structures is deeply analyzed in the European research project NEWREBAR “New Dual-Phase steel reinforcing bars for enhancing capacity and durability of anti-seismic moment resisting frames”, actually ongoing. The elaboration of new technical models for the design of RC elements, to be implemented in design guidelines and standards, is needed. In the present paper, preliminary results are presented concerning the selection of DP steel bars and the definition of technical models for RC elements with DP reinforcements
Echocardiographic evaluation of diastolic dysfunction in young and healthy patients with psoriasis: A case-control study
Psoriasis is a systemic inflammatory disease with a great prevalence in general population. The inappropriate activation of the cellular immune system has been hypothesized to be an independent cardiovascular risk factor, given the higher incidence of cardiovascular disorders in psoriatic patients. Echocardiographic abnormalities have been demonstrated too: the aim of our study was to evaluate the presence of preclinical cardiac dysfunction in a cohort of psoriatic patients without cardiovascular risk factors. We enrolled 52 patients with the diagnosis of chronic plaque psoriasis, compared with a control group not affected by any relevant systemic diseases and inflammatory disorders. In all patients and control group, echocardiographic conventional and tissue Doppler (TDI) studies were conducted. The analysis of echocardiographic parameters revealed normal dimension, mass and systolic function of the left ventricle. Left ventricular diastolic dysfunction was found in 36.5% patients in the psoriasis group versus 0% in control group, and significant reduction of the E/A ratio was found also for the right ventricle. A significant increase of mitral regurgitation has been found in psoriatic patients (p=0.005). The early recognition of cardiovascular pre-clinic disease in psoriatic patients may guide a strict follow up and an early treatment, potentially improving cardiovascular prognosis
Acute Delta Hepatitis in Italy spanning three decades (1991–2019): Evidence for the effectiveness of the hepatitis B vaccination campaign
Updated incidence data of acute Delta virus hepatitis (HDV) are lacking worldwide. Our aim was to evaluate incidence of and risk factors for acute HDV in Italy after the introduction of the compulsory vaccination against hepatitis B virus (HBV) in 1991. Data were obtained from the National Surveillance System of acute viral hepatitis (SEIEVA). Independent predictors of HDV were assessed by logistic-regression analysis. The incidence of acute HDV per 1-million population declined from 3.2 cases in 1987 to 0.04 in 2019, parallel to that of acute HBV per 100,000 from 10.0 to 0.39 cases during the same period. The median age of cases increased from 27 years in the decade 1991-1999 to 44 years in the decade 2010-2019 (p < .001). Over the same period, the male/female ratio decreased from 3.8 to 2.1, the proportion of coinfections increased from 55% to 75% (p = .003) and that of HBsAg positive acute hepatitis tested for by IgM anti-HDV linearly decreased from 50.1% to 34.1% (p < .001). People born abroad accounted for 24.6% of cases in 2004-2010 and 32.1% in 2011-2019. In the period 2010-2019, risky sexual behaviour (O.R. 4.2; 95%CI: 1.4-12.8) was the sole independent predictor of acute HDV; conversely intravenous drug use was no longer associated (O.R. 1.25; 95%CI: 0.15-10.22) with this. In conclusion, HBV vaccination was an effective measure to control acute HDV. Intravenous drug use is no longer an efficient mode of HDV spread. Testing for IgM-anti HDV is a grey area requiring alert. Acute HDV in foreigners should be monitored in the years to come
Increasing the Astrophysical Reach of the Advanced Virgo Detector via the Application of Squeezed Vacuum States of Light
Current interferometric gravitational-wave detectors are limited by quantum noise over a wide range of their measurement bandwidth. One method to overcome the quantum limit is the injection of squeezed vacuum states of light into the interferometer’s dark port. Here, we report on the successful application of this quantum technology to improve the shot noise limited sensitivity of the Advanced Virgo gravitational-wave detector. A sensitivity enhancement of up to 3.2±0.1 dB beyond the shot noise limit is achieved. This nonclassical improvement corresponds to a 5%–8% increase of the binary neutron star horizon. The squeezing injection was fully automated and over the first 5 months of the third joint LIGO-Virgo observation run O3 squeezing was applied for more than 99% of the science time. During this period several gravitational-wave candidates have been recorded
Quantum Backaction on kg-Scale Mirrors: Observation of Radiation Pressure Noise in the Advanced Virgo Detector
The quantum radiation pressure and the quantum shot noise in laser-interferometric gravitational wave detectors constitute a macroscopic manifestation of the Heisenberg inequality. If quantum shot noise can be easily observed, the observation of quantum radiation pressure noise has been elusive, so far, due to the technical noise competing with quantum effects. Here, we discuss the evidence of quantum radiation pressure noise in the Advanced Virgo gravitational wave detector. In our experiment, we inject squeezed vacuum states of light into the interferometer in order to manipulate the quantum backaction on the 42 kg mirrors and observe the corresponding quantum noise driven displacement at frequencies between 30 and 70 Hz. The experimental data, obtained in various interferometer configurations, is tested against the Advanced Virgo detector quantum noise model which confirmed the measured magnitude of quantum radiation pressure noise
Calibration of advanced Virgo and reconstruction of the detector strain h( t) during the observing run O3
The three advanced Virgo and LIGO gravitational wave detectors participated to the third observing run (O3) between 1 April 2019 15:00 UTC and 27 March 2020 17:00 UTC, leading to several gravitational wave detections per month. This paper describes the advanced Virgo detector calibration and the reconstruction of the detector strain h(t) during O3, as well as the estimation of the associated uncertainties. For the first time, the photon calibration technique as been used as reference for Virgo calibration, which allowed to cross-calibrate the strain amplitude of the Virgo and LIGO detectors. The previous reference, so-called free swinging Michelson technique, has still been used but as an independent cross-check. h(t) reconstruction and noise subtraction were processed online, with good enough quality to prevent the need for offline reprocessing, except for the two last weeks of September 2019. The uncertainties for the reconstructed h(t) strain, estimated in this paper in a 20-2000 Hz frequency band, are frequency independent: 5% in amplitude, 35 mrad in phase and 10 μs in timing, with the exception of larger uncertainties around 50 Hz
Advanced Virgo Plus: Future Perspectives
While completing the commissioning phase to prepare the Virgo interferometer for the next joint Observation Run (O4), the Virgo collaboration is also finalizing the design of the next upgrades to the detector to be employed in the following Observation Run (O5). The major upgrade will concern decreasing the thermal noise limit, which will imply using very large test masses and increased laser beam size. But this will not be the only upgrade to be implemented in the break between the O4 and O5 observation runs to increase the Virgo detector strain sensitivity. The paper will cover the challenges linked to this upgrade and implications on the detector's reach and observational potential, reflecting the talk given at 12th Cosmic Ray International Seminar - CRIS 2022 held in September 2022 in Napoli
- …