19 research outputs found

    Factors related to condomless anal intercourse between men who have sex with men: results from a European bio-behavioural survey

    Get PDF
    Background Relationship status is an important factor associated with condomless anal intercourse (CAI) amongst men who have sex with men (MSM). Methods A multi-centre bio-behavioural survey with MSM was conducted in 13 European cities (n=4,901) exploring factors associated with CAI via bivariate and multivariate multilevel logistic regression analyses. Results Likelihood of CAI with casual partners was associated with being ‘out’ to a majority (AOR=1.19;95% CI 1,1.42); knowing their HIV status (AOR=1.86; 95% CI 1.25,2.76); using substances (1-2 AOR=1.39; 95% CI 1.16,1.63, 2+ AOR=1.81; 95% CI 1.35,2.42); being older (AOR=0.98; 95% CI 0.97,0.99); successful sero-communication (AOR=0.79; 95% CI 0.67,0.94); and, not having a recent HIV test (AOR=0.78; 95% CI 0.66,0.92). CAI with steady partners was associated with successful sero-communication (AOR=2.72; 95% CI 2.72,3.66); not having a recent HIV test (AOR=1.26; 95% CI 1.09,1.46), and; being older (AOR=0.99; 95% CI 0.98,0.99). Conclusions Understandings of partner type and/or relationship status in relation to CAI amongst MSM can potentially play an important role in the development of culturally appropriate HIV/STI prevention and risk-reduction efforts targeting at-risk MSM. Our results speak to the need to consider segmented and tailored public health and health promotion initiatives for MSM with differing CAI behaviours and relationship profiles

    A multi-country comparative study of two treponemal tests for the serodiagnosis of Syphilis amongst Men Who Have Sex with Men (MSM):Chemo-luminescent assay vs Treponema pallidum particle agglutination assay

    Get PDF
    Introduction:International guidelines recommend routine screening for syphilis amongst keypopulations and vulnerable populations using tests detecting treponemal and nontreponemalantibodies. Whilst treponemal tests have high sensitivities and specificities,they differ regarding subjective or objective interpretation, throughput and workload.CLIAs are cost- and time-effective automated methods for detecting treponemalantibodies. The TPPA has been considered the “gold standard” treponemal assay,however, this includes a highly manual procedure, low throughput and subjectiveinterpretation. The present multi-country study evaluated the ADVIA Centaur® SyphilisCLIA assay compared to the reference SERODIA-TP·PA® for the serodiagnosis ofsyphilis amongst MSM.Method:1,485 MSM were enrolled in Brighton (UK), Malta, and Verona (Italy) as part of a largerWHO multi-country and multi-site ProSPeRo study. Serum was tested with the CLIAassay and TP·PA, in accordance with the manufacturers’ instructions, for a first roundof validation. A second round of validation was carried out for discrepant results thatwere additionally tested with both Western Blot and an Immunoblot.Sensitivity, specificity, positive and negative predictive value (PPV and NPV), likelihoodratios (positive/negative), and the Diagnostic Odds Ratio (DOR)/pre-post-testprobability were calculated.Results:Out of 1,485 eligible samples analysed in the first phase, the SERODIATP·PA identified 360 positive and 1,125 negative cases. The CLIA assay identified 366positives, missclassifying one TPPA-positive sample. In the second phase, the CLIAresulted in 1 false negative and 4 false positive results. Considering the syphilis studyprevalence of 24% (95% CI: 22-26.7), The sensitivity of the ADVIA Centaur® SyphilisCLIA assay was 99.7% (95% CI: 98.5-100), and the specificity was 99.4% (95% CI:98.7-99.7). The ROC area values were 0.996 (95% CI: 0.992-0.999), and both the PPVand NPV values were above 98%Conclusions:The CLIA assay showed similar performance compared to the SERODIA-TP·PA.Considering the study is based on QUADAS principles and with a homogeneouspopulation, results are also likely to be generalisable to MSM population but potentiallynot applicable to lower prevalence populations routinely screened for syphilis. Theautomated CLIA treponemal assay confirmed to be accurate and appropriate forroutine initial syphilis screening, i.e. when the reverse testing algorithm is applied

    SIALON II: Capacity building in combining targeted prevention with meaningful HIV surveillance among MSM: Report on a bio-behavioural survey among MSM in 13 European cities

    Get PDF
    The book presents the findings from a large-scale bio-behavioural survey implemented across 13 European countries. The survey was implemented in the context of the European Commission co-funded Sialon II project (see www.sialon.eu). The overall objective of the Sialon II project (2011-2014) was to carry out and promote combined and targeted prevention, complemented by meaningful surveillance, among MSM. The Sialon II project follows on from its predecessor Sialon (2008-2010); both projects were set within a context of rising HIV infections among MSM in many countries across Europe as indicated by both the ECDC and the other scientific literature

    Standards in semen examination:publishing reproducible and reliable data based on high-quality methodology

    Get PDF
    Biomedical science is rapidly developing in terms of more transparency, openness and reproducibility of scientific publications. This is even more important for all studies that are based on results from basic semen examination. Recently two concordant documents have been published: the 6th edition of the WHO Laboratory Manual for the Examination and Processing of Human Semen, and the International Standard ISO 23162:2021. With these tools, we propose that authors should be instructed to follow these laboratory methods in order to publish studies in peer-reviewed journals, preferable by using a checklist as suggested in an Appendix to this article.Peer reviewe

    Standards in semen examination: publishing reproducible and reliable data based on high-quality methodology

    Get PDF
    Biomedical science is rapidly developing in terms of more transparency, openness and reproducibility of scientific publications. This is even more important for all studies that are based on results from basic semen examination. Recently two concordant documents have been published: the 6th edition of the WHO Laboratory Manual for the Examination and Processing of Human Semen, and the International Standard ISO 23162:2021. With these tools, we propose that authors should be instructed to follow these laboratory methods in order to publish studies in peer-reviewed journals, preferable by using a checklist as suggested in an Appendix to this article

    Aortic root dilatation in patients with Alport’s syndrome

    No full text
    A total of 50 patients from 45 unrelated families diagnosed with Alport’s syndrome were examined. The diagnosis was based on molecular genetic testing or kidney biopsy. To assess changes in the aortic root, its volume was examined (calculation methods were given). Most patients with Alport’s syndrome were found to have cardiovascular disorders, such as hypertension; dilatation of the ring of the aortic valve; dilatation of the sinuses of Valsalva; some patients had dilatation of the sinotubular junction; dilatation of the ascending aorta; enlargement of the left ventricle; mitral and aortic insufficiency. In the patients with Alport’s syndrome, the median value of aortic root volume is 9.9 Z3, which substantially exceeds the permissible upper normal limit according to the general population data, which is 2.82 Z3. The rate of aortic root dilatation (volume increase) in the patients with Alport’s syndrome rises with an increase in the surface area of the body. In Alport’s syndrome, aortic root dilatation is unrelated to the presence of hypertension that occurs with a relative frequency of 0.52. Dilatation of the ascending aorta in Alport’s syndrome is diagnosed with a relative frequency of 0.37 and significantly more frequently diagnosed in male subjects (the statistical significance of a two-sided test is p=0.056; Fisher’s test is p=0.097; risk posed for men is OR = 7.2; 95% CI, 1.63-31.72. Changes in the cardiovascular system are also detected in female carriers of X-linked Alport’s syndrome; therefore they should be followed up by a cardiologist
    corecore