181 research outputs found
Muon-induced neutron production and detection with GEANT4 and FLUKA
We report on a comparison study of the Monte Carlo packages GEANT4 and FLUKA
for simulating neutron production by muons penetrating deep underground. GEANT4
is found to generate fewer neutrons at muon energies above ~100 GeV, by at most
a factor of 2 in some materials, which we attribute mainly to lower neutron
production in hadronic cascades. As a practical case study, the muon-induced
neutron background expected in a 250 kg liquid-xenon WIMP dark matter detector
was calculated and good agreement was found for the recoil event rates. The
detailed model of neutron elastic scattering in GEANT4 was also shown to
influence the nuclear recoil spectrum observed in the target, which is
presently a shortcoming of FLUKA. We conclude that both packages are suited for
this type of simulation, although further improvements are desirable in both
cases.Comment: (23 pages, 14 figures) To appear in Nucl. Instrum. Meth. A v2:
Changes to format only; v3: Corrected typo in front matter; v4: Looked up
additional experimental data for comparison with simulation
Detailed Calculation of Test-Mass Charging in the LISA Mission
The electrostatic charging of the LISA test masses due to exposure of the
spacecraft to energetic particles in the space environment has implications in
the design and operation of the gravitational inertial sensors and can affect
the quality of the science data. Robust predictions of charging rates and
associated stochastic fluctuations are therefore required for the exposure
scenarios expected throughout the mission. We report on detailed charging
simulations with the Geant4 toolkit, using comprehensive geometry and physics
models, for Galactic cosmic-ray protons and helium nuclei. These predict
positive charging rates of 50 +e/s (elementary charges per second) for solar
minimum conditions, decreasing by half at solar maximum, and current
fluctuations of up to 30 +e/s/Hz^{1/2}. Charging from sporadic solar events
involving energetic protons was also investigated. Using an event-size
distribution model, we conclude that their impact on the LISA science data is
manageable. Several physical processes hitherto unexplored as potential
charging mechanisms have also been assessed. Significantly, the kinetic
emission of very low-energy secondary electrons due to bombardment of the
inertial sensors by primary cosmic rays and their secondaries can produce
charging currents comparable with the Monte Carlo rates.Comment: 31 pages, 18 figures, 4 tables. to be published in Astroparticle
Physics. Changed due to error found in normalisation of the simulation
result
A Study of the Scintillation Induced by Alpha Particles and Gamma Rays in Liquid Xenon in an Electric Field
Scintillation produced in liquid xenon by alpha particles and gamma rays has
been studied as a function of applied electric field. For back scattered gamma
rays with energy of about 200 keV, the number of scintillation photons was
found to decrease by 64+/-2% with increasing field strength. Consequently, the
pulse shape discrimination power between alpha particles and gamma rays is
found to reduce with increasing field, but remaining non-zero at higher fields.Comment: 15 pages, 12 figures, accepted by Nuclear Instruments and Methods in
Physics Research
First Results from the DRIFT-IIa Dark Matter Detector
Data from the DRIFT-IIa directional dark matter experiment are presented,
collected during a near continuous 6 month running period. A detailed
calibration analysis comparing data from gamma-ray, x-ray and neutron sources
to a GEANT4 Monte Carlo simulations reveals an efficiency for detection of
neutron induced recoils of 94+/-2(stat.)+/-5(sys.)%. Software-based cuts,
designed to remove non-nuclear recoil events, are shown to reject 60Co
gamma-rays with a rejection factor of better than 8x10-6 for all energies above
threshold. An unexpected event population has been discovered and is shown here
to be due to the alpha-decay of 222Rn daughter nuclei that have attached to the
central cathode. A limit on the flux of neutrons in the Boulby Underground
Laboratory is derived from analysis of unshielded and shielded data.Comment: 43 pages, 14 figures, submitted to Astroparticle Physic
Track Reconstruction and Performance of DRIFT Directional Dark Matter Detectors using Alpha Particles
First results are presented from an analysis of data from the DRIFT-IIa and
DRIFT-IIb directional dark matter detectors at Boulby Mine in which alpha
particle tracks were reconstructed and used to characterise detector
performance--an important step towards optimising directional technology. The
drift velocity in DRIFT-IIa was [59.3 +/- 0.2 (stat) +/- 7.5 (sys)] m/s based
on an analysis of naturally-occurring alpha-emitting background. The drift
velocity in DRIFT-IIb was [57 +/- 1 (stat) +/- 3 (sys)] m/s determined by the
analysis of alpha particle tracks from a Po-210 source. 3D range reconstruction
and energy spectra were used to identify alpha particles from the decay of
Rn-222, Po-218, Rn-220 and Po-216. This study found that (22 +/- 2)% of Po-218
progeny (from Rn-222 decay) are produced with no net charge in 40 Torr CS2. For
Po-216 progeny (from Rn-220 decay) the uncharged fraction is (100 +0 -35)%.Comment: 27 pages, 12 figures, 5 tables. Submitted to Nuclear Instruments and
Methods in Physics Research, Section A. Subj-class: Instrumentation and
Detector
Measurement of single electron emission in two-phase xenon
We present the first measurements of the electroluminescence response to the
emission of single electrons in a two-phase noble gas detector. Single
ionization electrons generated in liquid xenon are detected in a thin gas layer
during the 31-day background run of the ZEPLIN-II experiment, a two-phase xenon
detector for WIMP dark matter searches. Both the pressure dependence and
magnitude of the single-electron response are in agreement with previous
measurements of electroluminescence yield in xenon. We discuss different
photoionization processes as possible cause for the sample of single electrons
studied in this work. This observation may have implications for the design and
operation of future large-scale two-phase systems.Comment: 11 pages, 6 figure
Reply to: Critical revision of the ZEPLIN-I sensitivity to WIMP interactions
Recent objections (Phys.Lett. B 637, 156) to the published Zeplin I limit
(Astropart. Phys 23, 444) are shown to arise from misunderstandings of the
calibration data and procedure, and a misreading of the data in one of the
referenced papers.Comment: 5 page
Sensitivity of the IceCube Detector to Astrophysical Sources of High Energy Muon Neutrinos
We present the results of a Monte-Carlo study of the sensitivity of the
planned IceCube detector to predicted fluxes of muon neutrinos at TeV to PeV
energies. A complete simulation of the detector and data analysis is used to
study the detector's capability to search for muon neutrinos from sources such
as active galaxies and gamma-ray bursts. We study the effective area and the
angular resolution of the detector as a function of muon energy and angle of
incidence. We present detailed calculations of the sensitivity of the detector
to both diffuse and pointlike neutrino emissions, including an assessment of
the sensitivity to neutrinos detected in coincidence with gamma-ray burst
observations. After three years of datataking, IceCube will have been able to
detect a point source flux of E^2*dN/dE = 7*10^-9 cm^-2s^-1GeV at a 5-sigma
significance, or, in the absence of a signal, place a 90% c.l. limit at a level
E^2*dN/dE = 2*10^-9 cm^-2s^-1GeV. A diffuse E-2 flux would be detectable at a
minimum strength of E^2*dN/dE = 1*10^-8 cm^-2s^-1sr^-1GeV. A gamma-ray burst
model following the formulation of Waxman and Bahcall would result in a 5-sigma
effect after the observation of 200 bursts in coincidence with satellite
observations of the gamma-rays.Comment: 33 pages, 13 figures, 6 table
The ZEPLIN II dark matter detector: data acquisition system and data reduction
ZEPLIN-II is a two-phase (liquid/gas) xenon dark matter detector searching
for WIMP-nucleon interactions. In this paper we describe the data acquisition
system used to record the data from ZEPLIN-II and the reduction procedures
which parameterise the data for subsequent analysis.Comment: 11 pages, 10 figure
The ZEPLIN II dark matter detector: data acquisition system and data reduction
ZEPLIN-II is a two-phase (liquid/gas) xenon dark matter detector searching
for WIMP-nucleon interactions. In this paper we describe the data acquisition
system used to record the data from ZEPLIN-II and the reduction procedures
which parameterise the data for subsequent analysis.Comment: 11 pages, 10 figure
- …