First results are presented from an analysis of data from the DRIFT-IIa and
DRIFT-IIb directional dark matter detectors at Boulby Mine in which alpha
particle tracks were reconstructed and used to characterise detector
performance--an important step towards optimising directional technology. The
drift velocity in DRIFT-IIa was [59.3 +/- 0.2 (stat) +/- 7.5 (sys)] m/s based
on an analysis of naturally-occurring alpha-emitting background. The drift
velocity in DRIFT-IIb was [57 +/- 1 (stat) +/- 3 (sys)] m/s determined by the
analysis of alpha particle tracks from a Po-210 source. 3D range reconstruction
and energy spectra were used to identify alpha particles from the decay of
Rn-222, Po-218, Rn-220 and Po-216. This study found that (22 +/- 2)% of Po-218
progeny (from Rn-222 decay) are produced with no net charge in 40 Torr CS2. For
Po-216 progeny (from Rn-220 decay) the uncharged fraction is (100 +0 -35)%.Comment: 27 pages, 12 figures, 5 tables. Submitted to Nuclear Instruments and
Methods in Physics Research, Section A. Subj-class: Instrumentation and
Detector