48 research outputs found

    A Multilaboratory Comparison of Calibration Accuracy and the Performance of External References in Analytical Ultracentrifugation

    Get PDF
    Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304 ± 0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of ± 0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies

    A multilaboratory comparison of calibration accuracy and the performance of external references in analytical ultracentrifugation.

    Get PDF
    Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304 ± 0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of ± 0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies

    Is poor performance on NBME clinical subject examinations associated with a failing score on the USMLE step 3 examination?

    No full text
    Purpose: To investigate the association between poor performance on National Board of Medical Examiners clinical subject examinations across six core clerkships and performance on the United States Medical Licensing Examination Step 3 examination. Method: In 2012, the authors studied matriculants from the Uniformed Services University of the Health Sciences with available Step 3 scores and subject exam scores on all six clerkships (Classes of 2007-2011, N = 654). Poor performance on subject exams was defined as scoring one standard deviation (SD) or more below the mean using the national norms of the corresponding test year. The association between poor performance on the subject exams and the probability of passing or failing Step 3 was tested using contingency table analyses and logistic regression modeling. Results Students performing poorly on one subject exam were significantly more likely to fail Step 3 (OR 14.23 [95% CI 1.7-119.3]) compared with students with no subject exam scores that were 1 SD below the mean. Poor performance on more than one subject exam further increased the chances of failing (OR 33.41 [95% CI 4.4-254.2]). This latter group represented 27% of the entire cohort, yet contained 70% of the students who failed Step 3. Conclusions: These findings suggest that individual schools could benefit from a review of subject exam performance to develop and validate their own criteria for identifying students at risk for failing Step 3

    Insuficiência respiratória aguda como manifestação da síndrome de eosinofilia-mialgia associada à ingestão de L-triptofano Acute respiratory failure as a manifestation of eosinophilia-myalgia syndrome associated with L-tryptophan intake

    Get PDF
    A síndrome da eosinofilia-mialgia foi descrita em 1989 em pacientes que apresentavam mialgia progressiva e incapacitante e eosinofilia sérica, nos líquidos e secreções. A maioria dos pacientes relatava uso prévio de L-triptofano. Sintomas respiratórios são relatados em até 80% dos casos, eventualmente como manifestação única. O tratamento inclui suspensão da droga e corticoterapia. Relatamos o caso de uma mulher de 61 anos com insuficiência respiratória aguda após uso de L-triptofano, hidroxitriptofano e outras drogas. A paciente apresentava eosinofilia no sangue, lavado broncoalveolar e derrame pleural. Após a suspensão da medicação e corticoterapia, houve melhora clínica e radiológica em poucos dias.<br>Eosinophilia-myalgia syndrome was described in 1989 in patients who presented progressive and incapacitating myalgia and eosinophilia in blood, fluids and secretions. Most patients report previous L-tryptophan intake. Respiratory manifestations are found in up to 80% of the cases, occasionally as the only manifestation. Treatment includes drug discontinuation and administration of corticosteroids. Here, we describe the case of a 61-year-old female admitted with acute respiratory failure after using L-tryptophan, hydroxytryptophan and other drugs. The patient presented eosinophilia, together with elevated eosinophil counts in the bronchoalveolar lavage and pleural effusion. After discontinuation of the drugs previously used, corticosteroids were administered, resulting in clinical and radiological improvement within just a few days