    Dynamic thermal simulation of advanced natural ventilation in buildings : current and future usage, UK exemplar

    Get PDF
    This paper evaluates the use of advanced natural ventilation (ANV) strategies in a range of climatic conditions from four cities in the UK. A prototype ANV system was proposed to determine the most effective case in mitigating overheating. The case was then assessed under identical simulation conditions for all four ANV strategies. The overheating criteria used in the research include the single temperature criterion from CIBSE Guide A and the adaptive thermal comfort overheating criteria from BS EN 15251. Both the current and future ‘Design Summer Year (DSY)’ weather data were used to examine the thermal performances of the proposed design. The findings show that shading, night cooling and heavy weight structures (ceiling) were all useful in mitigating overheating, with night cooling being identified as the most effective measure. The work assessed the use of ANV in both current and future scenarios to quantify the limits of outdoor environmental conditions under which natural ventilation is an effective strategy for achieving thermal comfort. The adaptive thermal comfort overheating criteria were proved to be easier to meet compared with the CIBSE single temperature criterion. With the adaptive overheating criteria, the given design is predicted to not overheat until 2050 in London Heathrow; and for other places evaluated in the UK (Edinburgh, Manchester & Birmingham), the design passes these criteria. The Centre-in ANV strategies proved to be more effective than the Edge-in strategies for space cooling due to the extended structure thermal mass

    A comparison of repaired, remanufactured and new compressors used in Western Australian small- and medium-sized enterprises in terms of global warming

    Get PDF
    Repaired compressors are compared with remanufactured and new compressors in terms of economic andenvironmental benefits. A detailed life cycle assessment has been carried out for compressors under threemanufacturing strategies: repaired, remanufactured and new equipment. The life cycle assessment of the globalwarming potential of repaired compressors varies from 4.38 to 119 kg carbon dioxide equivalent (CO2-e),depending on the type of components replaced. While greenhouse gas emissions from the remanufacturedcompressors (110 to 168 kg CO2-e) are relatively higher than those from the repaired ones (4.4 to 119 kg CO2-e), anew compressor has been found to produce a larger amount of greenhouse gas emissions (1,590 kg CO2-e)compared to both repaired and remanufactured compressors. Repairing failed compressors has been found to offerend users both dollar and carbon savings in contrast to remanufactured and new compressors. The research alsofound that extended lifetime is more important than the manufacturing processes in terms of greenhouse gasemissions. Since a remanufactured compressor offers a longer life than a repaired compressor, the replacement ofthe latter with the former can avoid 33% to 66% of the greenhouse gas emissions associated with a newcompressor production with a lifetime of 15 to 25 years

    Indoor comfort and adaptation in low-income and middle-income residential buildings in a Nigerian city during a dry season

    Get PDF
    This paper investigates occupants' comfort, adaptation and their responses during the dry season in low-income to middle-income residential buildings in Abuja, Nigeria. The study aims to provide empirical data on occupants' comfort through evaluating 171 households in four different locations in Abuja. The study considered a combination of different research methods for data collection. Post-occupancy surveys were used to evaluate the buildings and residents' adaptation within the thermal environment. Thermal comfort surveys were also carried out in eight low-income residential households to assess occupants' perception of the thermal environment. Based on the short duration of the physical measurements, building simulation was also used to examine thermal comfort of occupants for an extended period. The Post Occupancy Evaluation (POE) results revealed over 70% of the occupants were dissatisfied with their thermal environment. The comfort surveys reported similar results with over 65% of the responses revealed being ‘uncomfortably warm’. The results showed an overall mean temperature of all the measured case studies to be 31.7 °C and the average temperature (predicted) of 30.7 °C. The neutral temperatures were in a range of 28°C–30.4 °C compared to the preferred temperature range of 27.5°C–29.4 °C. The prevalence of thermal discomfort highlights the need to explore the possibilities of reducing internal temperatures, particularly by passive means (fabric, shading, insulation etc.) given the need to avoid or reduce the need for air conditioning to make the buildings energy-efficient for low to middle income groups

    Assessing and augmenting SCADA cyber security: a survey of techniques

    Get PDF
    SCADA systems monitor and control critical infrastructures of national importance such as power generation and distribution, water supply, transportation networks, and manufacturing facilities. The pervasiveness, miniaturisations and declining costs of internet connectivity have transformed these systems from strictly isolated to highly interconnected networks. The connectivity provides immense benefits such as reliability, scalability and remote connectivity, but at the same time exposes an otherwise isolated and secure system, to global cyber security threats. This inevitable transformation to highly connected systems thus necessitates effective security safeguards to be in place as any compromise or downtime of SCADA systems can have severe economic, safety and security ramifications. One way to ensure vital asset protection is to adopt a viewpoint similar to an attacker to determine weaknesses and loopholes in defences. Such mind sets help to identify and fix potential breaches before their exploitation. This paper surveys tools and techniques to uncover SCADA system vulnerabilities. A comprehensive review of the selected approaches is provided along with their applicability

    A review on food safety and food hygiene studies in Ghana

    Get PDF
    Food safety and hygiene in Ghana was studied using desk top literature review. Food research was highly concentrated in the capital city of the country and most research focus were on commercial food operations specifically street foods and microbiological safety with limited information from institutional catering and other forms of food hazards. The media currently serves as the main source for reporting of food borne diseases. Food establishments and other sources contributing to food borne diseases included restaurants, food joints, food vendors, schools and individual homes. Limited use of prerequisites measures and food safety management systems was identified. Recommendations on regulating the General Hygiene Principles, implementation of HACCP to strengthen the food sector, regular food safety and hygiene workshops and training for food handlers that commensurate with their roles were made. Government support for SMEs and food handler's health screening were made. © 2014 Elsevier Ltd

    Ventilation rates in naturally ventilated primary schools in the UK; Contextual, Occupant and Building-related (COB) factors

    Get PDF
    Indoor Air Quality (IAQ) in classrooms is assessed by CO2 levels and Ventilation Rates (VRs). Factors affecting VRs fall into Contextual, Occupant and Building (COB) related factors. This study investigates how VRs are affected by COB factors in 29 naturally-ventilated classrooms in the UK during Non-Heating and Heating seasons. Building-related factors classify classrooms with high or low potentials for natural ventilation, with 45% of classrooms having high potentials. Contextual factors including season, operative temperature (Top), outdoor temperature (Tout), ‘Top-Tout’ and air density can limit or increase VRs. Occupant-related factors classify occupant's good or poor practice of environmental adaptive behaviours. ‘Open area’ as a reflection of all COB factors is strongly correlated with ventilation rates. Results show that 12% and 19% of variations in ventilation rates are explained by open areas during non-heating and heating seasons, respectively. Findings highlight that to have VR of 8 ± 1.28 l/s.p during non-heating seasons and VR of 8 ± 1.07 l/s.p during heating seasons, average open areas of 3.8 m2 and 2 m2 are required, respectively. This difference can mostly be explained by temperature difference between inside and outside. Results show COB factors need to be considered holistically to maintain adequate VRs. Classrooms in which all COB factors are met provide average VR of 11 l/s.p and classrooms in which none of COB factors are met provide average VR is 3.1 l/s.p. This study highlights that 40% of classrooms according to EN 13779 and 80% of classrooms according to ASHRAE Standard fail to provide adequate VRs
    • …