50 research outputs found

    Room temperature near-ultraviolet emission from In-rich InGaN/GaN multiple quantum wells

    Get PDF
    We grew In-rich InGaNGaN multiple quantum wells (MQWs) using growth interruption (GI) by metalorganic chemical vapor deposition. The quality of overgrown InGaNGaN QW layers in MQWs was largely affected by the crystalline quality and interfacial abruptness of the underlying QW layer. Introduction of 10 s GI was very effective in improving the crystalline quality and interfacial abruptness of InGaN QW layers, and we grew a ten periods of 1-nm -thick In-rich InGaNGaN MQW with 10 s GI and obtained a strong near-ultraviolet (UV) emission (~390 nm) at room temperature. We believe that use of less than 1-nm -thick In-rich InGaN MQW can be a candidate for near-UV source, which might replace the conventional low-indium content (<10%), thicker InGaN QW layer.open313

    Photo-stability study of a solution-processed small molecule solar cell system: correlation between molecular conformation and degradation

    Get PDF
    <p>Solution-processed organic small molecule solar cells (SMSCs) have achieved efficiency over 11%. However, very few studies have focused on their stability under illumination and the origin of the degradation during the so-called burn-in period. Here, we studied the burn-in period of a solution-processed SMSC using benzodithiophene terthiophene rhodamine:[6,6]-phenyl C<sub>71</sub> butyric acid methyl ester (BTR:PC<sub>71</sub>BM) with increasing solvent vapour annealing time applied to the active layer, controlling the crystallisation of the BTR phase. We find that the burn-in behaviour is strongly correlated to the crystallinity of BTR. To look at the possible degradation mechanisms, we studied the fresh and photo-aged blend films with grazing incidence X-ray diffraction, UV–vis absorbance, Raman spectroscopy and photoluminescence (PL) spectroscopy. Although the crystallinity of BTR affects the performance drop during the burn-in period, the degradation is found not to originate from the crystallinity changes of the BTR phase, but correlates with changes in molecular conformation – rotation of the thiophene side chains, as resolved by Raman spectroscopy which could be correlated to slight photobleaching and changes in PL spectra.</p

    Single nanowire-based UV photodetectors for fast switching

    Get PDF
    Relatively long (30 µm) high quality ZnO nanowires (NWs) were grown by the vapor-liquid-solid (VLS) technique. Schottky diodes of single NW were fabricated by putting single ZnO NW across Au and Pt electrodes. A device with ohmic contacts at both the sides was also fabricated for comparison. The current-voltage (I-V) measurements for the Schottky diode show clear rectifying behavior and no reverse breakdown was seen down to -5 V. High current was observed in the forward bias and the device was found to be stable up to 12 V applied bias. The Schottky barrier device shows more sensitivity, lower dark current, and much faster switching under pulsed UV illumination. Desorption and re-adsorption of much smaller number of oxygen ions at the Schottky junction effectively alters the barrier height resulting in a faster response even for very long NWs. The NW was treated with oxygen plasma to improve the switching. The photodetector shows high stability, reversibility, and sensitivity to UV light. The results imply that single ZnO NW Schottky diode is a promising candidate for fabricating UV photodetectors

    Salvage chemotherapy of biweekly irinotecan plus S-1 (biweekly IRIS) in previously treated patients with advanced gastric cancer

    Get PDF
    PURPOSE: This phase II trial first describes the combination chemotherapy of biweekly irinotecan plus S-1 (biweekly IRIS) for pretreated advanced gastric cancer (AGC) patients. METHODS: Patients who had previously been treated with greater than or equal to one regimen were enrolled. They received S-1 35 mg/m(2) twice daily on days 1-14 and irinotecan 150 mg/m(2) on days 1 and 15, every 4 weeks. The primary endpoint was overall survival (OS). RESULTS: Among the 38 patients enrolled, 18 patients were treated as second line, and the remaining 20 patients were enrolled as third- or fourth line. A total of 208 cycles were administered with the median being four cycles (range 1-16). The median OS was 8.7 months [95% confidence interval (CI) 7.5-10.3], and the median progression-free survival was 6.3 months (95% CI 5.3-7.3). Low serum albumin (<3.5 mg/dL) was an independent adverse prognosticator for survival. Overall response rate was 17% (95% CI 4-30%). The major grade 3/4 toxicities were neutropenia (26%) and diarrhea (18%). CONCLUSIONS: Biweekly IRIS showed the moderate activity as salvage treatment in AGC. Considering high neutropenia and gastrointestinal toxicity, patient selection should be warranted; serum albumin may be a predictive factor for treatment decisionope

    Polaron pair mediated triplet generation in polymer/fullerene blends

    Get PDF
    Electron spin is a key consideration for the function of organic semiconductors in light-emitting diodes and solar cells, as well as spintronic applications relying on organic magnetoresistance. A mechanism for triplet excited state generation in such systems is by recombination of electron-hole pairs. However, the exact charge recombination mechanism, whether geminate or nongeminate and whether it involves spin-state mixing is not well understood. In this work, the dynamics of free charge separation competing with recombination to polymer triplet states is studied in two closely related polymer-fullerene blends with differing polymer fluorination and photovoltaic performance. Using time-resolved laser spectroscopic techniques and quantum chemical calculations, we show that lower charge separation in the fluorinated system is associated with the formation of bound electron-hole pairs, which undergo spin-state mixing on the nanosecond timescale and subsequent geminate recombination to triplet excitons. We find that these bound electron-hole pairs can be dissociated by electric fields

    Axillary lymph node dissection for breast cancer utilizing Harmonic Focus®

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>For patients with axillary lymph node metastases from breast cancer, performance of a complete axillary lymph node dissection (ALND) is the standard approach. Due to the rich lymphatic network in the axilla, it is necessary to carefully dissect and identify all lymphatic channels. Traditionally, these lymphatics are sealed with titanium clips or individually sutured. Recently, the Harmonic Focus<sup>®</sup>, a hand-held ultrasonic dissector, allows lymphatics to be sealed without the utilization of clips or ties. We hypothesize that ALND performed with the Harmonic Focus<sup>® </sup>will decrease operative time and reduce post-operative complications.</p> <p>Methods</p> <p>Retrospective review identified all patients who underwent ALND at a teaching hospital between January of 2005 and December of 2009. Patient demographics, presenting pathology, treatment course, operative time, days to drain removal, and surgical complications were recorded. Comparisons were made to a selected control group of patients who underwent similar surgical procedures along with an ALND performed utilizing hemostatic clips and electrocautery. A total of 41 patients were included in this study.</p> <p>Results</p> <p>Operative time was not improved with the use of ultrasonic dissection, however, there was a decrease in the total number of days that closed suction drainage was required, although this was not statistically significant. Complication rates were similar between the two groups.</p> <p>Conclusion</p> <p>In this case-matched retrospective review, there were fewer required days of closed suction drainage when ALND was performed with ultrasonic dissection versus clips and electrocautery.</p

    Phosphorylation of Nicastrin by SGK1 Leads to Its Degradation through Lysosomal and Proteasomal Pathways

    Get PDF
    The gamma-secretase complex is involved in the intramembranous proteolysis of a variety of substrates, including the amyloid precursor protein and the Notch receptor. Nicastrin (NCT) is an essential component of the gamma-secretase complex and functions as a receptor for gamma-secretase substrates. In this study, we determined that serum- and glucocorticoid-induced protein kinase 1 (SGK1) markedly reduced the protein stability of NCT. The SGK1 kinase activity was decisive for NCT degradation and endogenous SGK1 inhibited gamma-secretase activity. SGK1 downregulates NCT protein levels via proteasomal and lysosomal pathways. Furthermore, SGK1 directly bound to and phosphorylated NCT on Ser437, thereby promoting protein degradation. Collectively, our findings indicate that SGK1 is a gamma-secretase regulator presumably effective through phosphorylation and degradation of NCT

    Pooled analysis of WHO Surgical Safety Checklist use and mortality after emergency laparotomy

    Get PDF
    Background The World Health Organization (WHO) Surgical Safety Checklist has fostered safe practice for 10 years, yet its place in emergency surgery has not been assessed on a global scale. The aim of this study was to evaluate reported checklist use in emergency settings and examine the relationship with perioperative mortality in patients who had emergency laparotomy. Methods In two multinational cohort studies, adults undergoing emergency laparotomy were compared with those having elective gastrointestinal surgery. Relationships between reported checklist use and mortality were determined using multivariable logistic regression and bootstrapped simulation. Results Of 12 296 patients included from 76 countries, 4843 underwent emergency laparotomy. After adjusting for patient and disease factors, checklist use before emergency laparotomy was more common in countries with a high Human Development Index (HDI) (2455 of 2741, 89.6 per cent) compared with that in countries with a middle (753 of 1242, 60.6 per cent; odds ratio (OR) 0.17, 95 per cent c.i. 0.14 to 0.21, P <0001) or low (363 of 860, 422 per cent; OR 008, 007 to 010, P <0.001) HDI. Checklist use was less common in elective surgery than for emergency laparotomy in high-HDI countries (risk difference -94 (95 per cent c.i. -11.9 to -6.9) per cent; P <0001), but the relationship was reversed in low-HDI countries (+121 (+7.0 to +173) per cent; P <0001). In multivariable models, checklist use was associated with a lower 30-day perioperative mortality (OR 0.60, 0.50 to 073; P <0.001). The greatest absolute benefit was seen for emergency surgery in low- and middle-HDI countries. Conclusion Checklist use in emergency laparotomy was associated with a significantly lower perioperative mortality rate. Checklist use in low-HDI countries was half that in high-HDI countries.Peer reviewe
    corecore