320 research outputs found

    Radiofrequency ablation of small liver malignancies under magnetic resonance guidance: progress in targeting and preliminary observations with temperature monitoring

    Get PDF
    Objectives: To evaluate the feasibility and effectiveness of magnetic resonance (MR)-guided radiofrequency (RF) ablation for small liver tumours with poor conspicuity on both contrast-enhanced ultrasonography (US) and computed tomography (CT), using fast navigation and temperature monitoring. Methods: Sixteen malignant liver nodules (long-axis diameter, 0.6-2.4cm) were treated with multipolar RF ablation on a 1.5-T wide-bore MR system in ten patients. Targeting was performed interactively, using a fast steady-state free precession sequence. Real-time MR-based temperature mapping was performed, using gradient echo-echo planar imaging (GRE-EPI) and hardware filtering. MR-specific treatment data were recorded. The mean follow-up time was 19 ± 7months. Results: Correct placement of RF electrodes was obtained in all procedures (image update, <500ms; mean targeting time, 21 ± 11min). MR thermometry was available for 14 of 16 nodules (88%) with an accuracy of 1.6°C in a non-heated region. No correlation was found between the size of the lethal thermal dose and the ablation zone at follow-up imaging. The primary and secondary effectiveness rates were 100% and 91%, respectively. Conclusions: RF ablation of small liver tumours can be planned, targeted, monitored and controlled with MR imaging within acceptable procedure times. Temperature mapping is technically feasible, but the clinical benefit remains to be prove

    Heterogeneous cavitation from atomically smooth liquid-liquid interfaces

    Full text link
    Pressure reduction in liquids may result in vaporization and bubble formation. This thermodynamic process is termed cavitation. It is commonly observed in hydraulic machinery, ship propellers, and even in medical therapy within the human body. While cavitation may be beneficial for the removal of malign tissue, yet in many cases it is unwanted due to its ability to erode nearly any material in close contact. Current understanding is that the origin of heterogeneous cavitation are nucleation sites where stable gas cavities reside, e.g., on contaminant particles, submerged surfaces or shell stabilized microscopic bubbles. Here, we present the finding of a so far unreported nucleation site, namely the atomically smooth interface between two immiscible liquids. The non-polar liquid of the two has a higher gas solubility and acts upon pressure reduction as a gas reservoir that accumulates at the interface. We describe experiments that clearly reveal the formation of cavitation on non-polar droplets in contact with water and elucidate the working mechanism that leads to the nucleation of gas pockets through simulations.Comment: This preprint has not undergone peer review or any post-submission improvements or corrections. The Version of Record of this article is published in Nature Physics, and is available online at https://doi.org/10.1038/s41567-022-01764-

    Inter-fractional Respiratory Motion Modelling from Abdominal Ultrasound: A Feasibility Study

    Get PDF
    Motion management strategies are crucial for radiotherapy of mobile tumours in order to ensure proper target coverage, save organs at risk and prevent interplay effects. We present a feasibility study for an inter-fractional, patient-specific motion model targeted at active beam scanning proton therapy. The model is designed to predict dense lung motion information from 2D abdominal ultrasound images. In a pretreatment phase, simultaneous ultrasound and magnetic resonance imaging are used to build a regression model. During dose delivery, abdominal ultrasound imaging serves as a surrogate for lung motion prediction. We investigated the performance of the motion model on five volunteer datasets. In two cases, the ultrasound probe was replaced after the volunteer has stood up between two imaging sessions. The overall mean prediction error is 2.9 mm and 3.4 mm after repositioning and therefore within a clinically acceptable range. These results suggest that the ultrasound-based regression model is a promising approach for inter-fractional motion management in radiotherapy

    Heating in the MRI environment due to superparamagnetic fluid suspensions in a rotating magnetic field

    Get PDF
    2011 March 1In the presence of alternating-sinusoidal or rotating magnetic fields, magnetic nanoparticles will act to realign their magnetic moment with the applied magnetic field. The realignment is characterized by the nanoparticle's time constant, τ. As the magnetic field frequency is increased, the nanoparticle's magnetic moment lags the applied magnetic field at a constant angle for a given frequency, Ω, in rad/s. Associated with this misalignment is a power dissipation that increases the bulk magnetic fluid's temperature which has been utilized as a method of magnetic nanoparticle hyperthermia, particularly suited for cancer in low-perfusion tissue (e.g., breast) where temperature increases of between 4 and 7 degree Centigrade above the ambient in vivo temperature cause tumor hyperthermia. This work examines the rise in the magnetic fluid's temperature in the MRI environment which is characterized by a large DC field, B0. Theoretical analysis and simulation is used to predict the effect of both alternating-sinusoidal and rotating magnetic fields transverse to B0. Results are presented for the expected temperature increase in small tumors (approximately 1 cm radius) over an appropriate range of magnetic fluid concentrations (0.002–0.01 solid volume fraction) and nanoparticle radii (1–10 nm). The results indicate that significant heating can take place, even in low-field MRI systems where magnetic fluid saturation is not significant, with careful selection of the rotating or sinusoidal field parameters (field frequency and amplitude). The work indicates that it may be feasible to combine low-field MRI with a magnetic hyperthermia system using superparamagnetic iron oxide nanoparticles.National Institutes of Health (U.S.

    Fast nonlinear susceptibility inversion with variational regularization

    Get PDF
    PURPOSE: Quantitative susceptibility mapping can be performed through the minimization of a function consisting of data fidelity and regularization terms. For data consistency, a Gaussian-phase noise distribution is often assumed, which breaks down when the signal-to-noise ratio is low. A previously proposed alternative is to use a nonlinear data fidelity term, which reduces streaking artifacts, mitigates noise amplification, and results in more accurate susceptibility estimates. We hereby present a novel algorithm that solves the nonlinear functional while achieving computation speeds comparable to those for a linear formulation. METHODS: We developed a nonlinear quantitative susceptibility mapping algorithm (fast nonlinear susceptibility inversion) based on the variable splitting and alternating direction method of multipliers, in which the problem is split into simpler subproblems with closed-form solutions and a decoupled nonlinear inversion hereby solved with a Newton-Raphson iterative procedure. Fast nonlinear susceptibility inversion performance was assessed using numerical phantom and in vivo experiments, and was compared against the nonlinear morphology-enabled dipole inversion method. RESULTS: Fast nonlinear susceptibility inversion achieves similar accuracy to nonlinear morphology-enabled dipole inversion but with significantly improved computational efficiency. CONCLUSION: The proposed method enables accurate reconstructions in a fraction of the time required by state-of-the-art quantitative susceptibility mapping methods. Magn Reson Med, 2018. © 2018 International Society for Magnetic Resonance in Medicine

    Multi-modal characterization of rapid anterior hippocampal volume increase associated with aerobic exercise.

    Get PDF
    The hippocampus has been shown to demonstrate a remarkable degree of plasticity in response to a variety of tasks and experiences. For example, the size of the human hippocampus has been shown to increase in response to aerobic exercise. However, it is currently unknown what underlies these changes. Here we scanned sedentary, young to middle-aged human adults before and after a six-week exercise intervention using nine different neuroimaging measures of brain structure, vasculature, and diffusion. We then tested two different hypotheses regarding the nature of the underlying changes in the tissue. Surprisingly, we found no evidence of a vascular change as has been previously reported. Rather, the pattern of changes is better explained by an increase in myelination. Finally, we show hippocampal volume increase is temporary, returning to baseline after an additional six weeks without aerobic exercise. This is the first demonstration of a change in hippocampal volume in early to middle adulthood suggesting that hippocampal volume is modulated by aerobic exercise throughout the lifespan rather than only in the presence of age related atrophy. It is also the first demonstration of hippocampal volume change over a period of only six weeks, suggesting gross morphometric hippocampal plasticity occurs faster than previously thought

    MR fluoroscopy in vascular and cardiac interventions (review)

    Get PDF
    Vascular and cardiac disease remains a leading cause of morbidity and mortality in developed and emerging countries. Vascular and cardiac interventions require extensive fluoroscopic guidance to navigate endovascular catheters. X-ray fluoroscopy is considered the current modality for real time imaging. It provides excellent spatial and temporal resolution, but is limited by exposure of patients and staff to ionizing radiation, poor soft tissue characterization and lack of quantitative physiologic information. MR fluoroscopy has been introduced with substantial progress during the last decade. Clinical and experimental studies performed under MR fluoroscopy have indicated the suitability of this modality for: delivery of ASD closure, aortic valves, and endovascular stents (aortic, carotid, iliac, renal arteries, inferior vena cava). It aids in performing ablation, creation of hepatic shunts and local delivery of therapies. Development of more MR compatible equipment and devices will widen the applications of MR-guided procedures. At post-intervention, MR imaging aids in assessing the efficacy of therapies, success of interventions. It also provides information on vascular flow and cardiac morphology, function, perfusion and viability. MR fluoroscopy has the potential to form the basis for minimally invasive image–guided surgeries that offer improved patient management and cost effectiveness
    corecore