566 research outputs found

    Improved Iterative Coordinated Beamforming Based on Singular Value Decomposition for Multiuser Mimo Systems With Limited Feedforward

    Get PDF
    Coordinated beamforming based on singular value decomposition is an iterative method to jointly optimize thetransmit beamformers and receive combiners, to achieve high levels of sum rates in the downlink of multiusersystems, by exploiting the multi-dimensional wireless channel created by multiple transmit and receive antennas. The optimization is done at the base station and the quantized beamformers are sent to the users through a low rate link.In this work, we propose to optimize this algorithm by reducing the number of iterations and improving its uncoded bit error rate performance. Simulation results show that our proposal achieves a better bit error rate with a lower number of iterations than the original algorithm

    Laminosioptes cysticola and Gallibacterium anatis infections in a lymphoma diseased chicken hen with a cystic right oviduct

    Get PDF
    A domestic hen showing infraorbital swelling was presented for a routine classroom demonstration of avian diagnostics. At necropsy, tiny whitish caseo-calcareous nodules were found in the subcutaneous tissues of the carcass, produced by the subcutaneous fowl mite, Laminosioptes cysticola. Gallibacterium anatis biovar haemolytica was isolated from the infraorbital sinus, it containing a caseous exudate. During necropsy, a conspicuous cyst was found in the abdominal cavity. Microscopic examination of the internal lining of the cyst revealed a single cuboidal to columnar, ciliated epithelium, leading to a diagnosis of oviductal cyst. Also, the microscopic examination of the heart, lung, liver and kidney reveal a multifocal infiltration of lymphoma cells. It appears the first case of simultaneous presentation of these conditions from a single chicken

    Implementation and analysis of list mode algorithm using tubes of response on a dedicated brain and breast PET

    Full text link
    In this work we present an innovative algorithm for the reconstruction of PET images based on the List-Mode (LM) technique which improves their spatial resolution compared to results obtained with current MLEM algorithms. This study appears as a part of a large project with the aim of improving diagnosis in early Alzheimer disease stages by means of a newly developed hybrid PET-MR insert. At the present, Alzheimer is the most relevant neurodegenerative disease and the best way to apply an effective treatment is its early diagnosis. The PET device will consist of several monolithic LYSO crystals coupled to SiPM detectors. Monolithic crystals can reduce scanner costs with the advantage to enable implementation of very small virtual pixels in their geometry. This is especially useful for LM reconstruction algorithms, since they do not need a pre-calculated system matrix. We have developed an LM algorithm which has been initially tested with a large aperture (186 mm) breast PET system. Such an algorithm instead of using the common lines of response, incorporates a novel calculation of tubes of response. The new approach improves the volumetric spatial resolution about a factor 2 at the border of the field of view when compared with traditionally used MLEM algorithm. Moreover, it has also shown to decrease the image noise, thus increasing the image quality. © 2012 Elsevier B.V. All rights reserved.This work was supported by the Centre for Industrial Technological Development co-funded by FEDER through the Technology Fund (DREAM Project, IDI-20110718), by the Spanish Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica (I+D+I) under Grant. No. FIS2010-21216-CO2-01TEO 2008/114.Moliner Martínez, L.; Correcher, C.; González Martínez, AJ.; Conde Castellanos, PE.; Hernández Hernández, L.; Orero Palomares, A.; Rodríguez Álvarez, MJ.... (2013). Implementation and analysis of list mode algorithm using tubes of response on a dedicated brain and breast PET. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 702:129-132. https://doi.org/10.1016/j.nima.2012.08.029S12913270

    Cambios precoces en la tomografía de coherencia óptica en un niño con maculopatía inducida por puntero láser.

    Get PDF
    Niño de 9 años de edad, que refiere pérdida visual en su ojo derecho, después de jugar con un puntero láser. En la primera exploración (12h después) la agudeza visual (AV) era 0,15, la fóvea presentaba una lesión hipopigmentada, y la tomografía de coherencia óptica (OCT) demuestra la presencia de bandas hiperreflectivas verticales. Al cabo de 6 meses, la AV había mejorado a 0,5 y se aprecia en la OCT un área bien definida de interrupción de la retina externa. Discusión Un inadecuado uso de los punteros láser, puede producir pérdida visual severa e irreversible.pre-print671 K

    Prospective analysis of psychological differences between adult and elderly cancer patients during postoperaritve adjuvant chemotherapy

    Full text link
    PURPOSE: Despite the burgeoning geriatric population with cancer and the importance of understanding how age may be related to mental adjustment and quality of life so far, differences in coping strategies and psychological harm between the elderly and adults are hardly being taken into account to modify the approach to this population. The aim of this prospective study is to describe the differences in psychological characteristics between older and adult cancer patients and examine dissimilarities in their psychological evolution during adjuvant chemotherapy. METHODS: Adults (18-69 years old) and older patients (≥ 70) with newly diagnosed non-metastatic resected cancer admitted to receive adjuvant chemotherapy were recruited. Patients completed the following questionnaires: mini-mental adjustment to cancer, brief symptom inventory, shared decision-making questionnaire-patient's version, multidimensional scale of perceived social support, EORTC quality-of-life instrument, life orientation test-revised, and satisfaction with life scale. RESULTS: 500 cancer patients (394 adults and 106 older) were evaluated. The impact of the diagnosis was less negative among older patients, with no differences in coping strategies, quality of life, or search for support. Regarding psychological changes from the beginning to the end of the adjuvant treatment, both age groups reported more somatic symptoms, increased psychological difficulty, reduced coping strategies, and a significant decrease in quality of life at the end of postoperative chemotherapy. CONCLUSION: Although there were clear psychological differences between adults and senior cancer patients, their evolution during adjuvant chemotherapy was similar, with deterioration in quality of life and coping. This negative psychological impact of adjuvant chemotherapy should be taken into account when considering interventions

    Gram-negative prosthetic joint infection: outcome of a debridement, antibiotics and implant retention approach. A large multicentre study

    Get PDF
    AbstractWe aim to evaluate the epidemiology and outcome of gram-negative prosthetic joint infection (GN-PJI) treated with debridement, antibiotics and implant retention (DAIR), identify factors predictive of failure, and determine the impact of ciprofloxacin use on prognosis. We performed a retrospective, multicentre, observational study of GN-PJI diagnosed from 2003 through to 2010 in 16 Spanish hospitals. We define failure as persistence or reappearance of the inflammatory joint signs during follow-up, leading to unplanned surgery or repeat debridement >30 days from the index surgery related death, or suppressive antimicrobial therapy. Parameters predicting failure were analysed with a Cox regression model. A total of 242 patients (33% men; median age 76 years, interquartile range (IQR) 68–81) with 242 episodes of GN-PJI were studied. The implants included 150 (62%) hip, 85 (35%) knee, five (2%) shoulder and two (1%) elbow prostheses. There were 189 (78%) acute infections. Causative microorganisms were Enterobacteriaceae in 78%, Pseudomonas spp. in 20%, and other gram-negative bacilli in 2%. Overall, 19% of isolates were ciprofloxacin resistant. DAIR was used in 174 (72%) cases, with an overall success rate of 68%, which increased to 79% after a median of 25 months' follow-up in ciprofloxacin-susceptible GN-PJIs treated with ciprofloxacin. Ciprofloxacin treatment exhibited an independent protective effect (adjusted hazard ratio (aHR) 0.23; 95% CI, 0.13–0.40; p <0.001), whereas chronic renal impairment predicted failure (aHR, 2.56; 95% CI, 1.14–5.77; p 0.0232). Our results confirm a 79% success rate in ciprofloxacin-susceptible GN-PJI treated with debridement, ciprofloxacin and implant retention. New therapeutic strategies are needed for ciprofloxacin-resistant PJI

    ALBIRA: A small animal PET/SPECT/CT imaging system

    Full text link
    Purpose: The authors have developed a trimodal PET/SPECT/CT scanner for small animal imaging. The gamma ray subsystems are based on monolithic crystals coupled to multianode photomultiplier tubes (MA-PMTs), while computed tomography (CT) comprises a commercially available microfocus x-ray tube and a CsI scintillator 2D pixelated flat panel x-ray detector. In this study the authors will report on the design and performance evaluation of the multimodal system. Methods: X-ray transmission measurements are performed based on cone-beam geometry. Individual projections were acquired by rotating the x-ray tube and the 2D flat panel detector, thus making possible a transaxial field of view (FOV) of roughly 80 mm in diameter and an axial FOV of 65 mm for the CT system. The single photon emission computed tomography (SPECT) component has a dual head detector geometry mounted on a rotating gantry. The distance between the SPECT module detectors can be varied in order to optimize specific user requirements, including variable FOV. The positron emission tomography (PET) system is made up of eight compact modules forming an octagon with an axial FOV of 40 mm and a transaxial FOV of 80 mm in diameter. The main CT image quality parameters (spatial resolution and uniformity) have been determined. In the case of the SPECT, the tomographic spatial resolution and system sensitivity have been evaluated with a99mTc solution using single-pinhole and multi-pinhole collimators. PET and SPECT images were reconstructed using three-dimensional (3D) maximum likelihood and ordered subset expectation maximization (MLEM and OSEM) algorithms developed by the authors, whereas the CT images were obtained using a 3D based FBP algorithm. Results: CT spatial resolution was 85μm while a uniformity of 2.7% was obtained for a water filled phantom at 45 kV. The SPECT spatial resolution was better than 0.8 mm measured with a Derenzo-like phantom for a FOV of 20 mm using a 1-mm pinhole aperture collimator. The full width at half-maximum PET radial spatial resolution at the center of the field of view was 1.55 mm. The SPECT system sensitivity for a FOV of 20 mm and 15% energy window was 700 cps/MBq (7.8 × 10−2%) using a multi-pinhole equipped with five apertures 1 mm in diameter, whereas the PET absolute sensitivity was 2% for a 350–650 keV energy window and a 5 ns timing window. Several animal images are also presented. Conclusions: The new small animal PET/SPECT/CT proposed here exhibits high performance, producing high-quality images suitable for studies with small animals. Monolithic design for PET and SPECT scintillator crystals reduces cost and complexity without significant performance degradation.This study was supported by the Spanish Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica (I+D+I) under Grant No. FIS2010-21216-CO2-01 and Valencian Local Government under Grant PROMETEO 2008/114. The authors also thank Brennan Holt for checking and correcting the text.Sánchez Martínez, F.; Orero Palomares, A.; Soriano Asensi, A.; Correcher Salvador, C.; Conde Castellanos, PE.; González Martínez, AJ.; Hernández Hernández, L.... (2013). ALBIRA: A small animal PET/SPECT/CT imaging system. Medical Physics. 40(5):5190601-5190611. https://doi.org/10.1118/1.4800798S5190601519061140

    Spectral characterization of laser-accelerated protons with CR-39 nuclear track detector

    Get PDF
    CR-39 nuclear track material is frequently used for the detection of protons accelerated in laser-plasma interactions. The measurement of track densities allows for determination of particle angular distributions, and information on the kinetic energy can be obtained by the use of passive absorbers. We present a precise method of measuring spectral distributions of laser-accelerated protons in a single etching and analysis process. We make use of a one-to-one relation between proton energy and track size and present a precise calibration based on monoenergetic particle beams. While this relation is limited to proton energies below 1 MeV, we show that the range of spectral measurements can be significantly extended by simultaneous use of absorbers of suitable thicknesses. Examples from laser-plasma interactions are presented, and quantitative results on proton energies and particle numbers are compared to those obtained from a time-of-flight detector. The spectrum end points of continuous energy distributions have been determined with both detector types and coincide within 50-100 keV

    Molecular and brain volume changes following aerobic exercise, cognitive and combined training in physically inactive healthy Late-Middle-Aged Adults: The Projecte Moviment Randomized Controlled Trial

    Get PDF
    Behavioral interventions have shown promising neuroprotective effects, but the cascade of molecular, brain and behavioral changes involved in these benefits remains poorly understood. Projecte Moviment is a 12-week (5 days per week—45 min per day) multi-domain, single-blind, proof-of-concept randomized controlled trial examining the cognitive effect and underlying mechanisms of an aerobic exercise (AE), computerized cognitive training (CCT) and a combined (COMB) groups compared to a waitlist control group. Adherence was > 80% for 82/109 participants recruited (62% female; age = 58.38 ± 5.47). In this study we report intervention-related changes in plasma biomarkers (BDNF, TNF-α, HGF, ICAM-1, SDF1-α) and structural-MRI (brain volume) and how they related to changes in physical activity and individual variables (age and sex) and their potential role as mediators in the cognitive changes. Our results show that although there were no significant changes in molecular biomarker concentrations in any intervention group, changes in ICAM-1 and SDF1-α were negatively associated with changes in physical activity outcomes in AE and COMB groups. Brain volume changes were found in the CCT showing a significant increase in precuneus volume. Sex moderated the brain volume change in the AE and COMB groups, suggesting that men may benefit more than women. Changes in molecular biomarkers and brain volumes did not significantly mediate the cognitive-related benefits found previously for any group. This study shows crucial initial molecular and brain volume changes related to lifestyle interventions at early stages and highlights the value of examining activity parameters, individual difference characteristics and using a multi-level analysis approach to address these questions
    corecore