59 research outputs found

    An improved method for measuring muon energy using the truncated mean of dE/dx

    Full text link
    The measurement of muon energy is critical for many analyses in large Cherenkov detectors, particularly those that involve separating extraterrestrial neutrinos from the atmospheric neutrino background. Muon energy has traditionally been determined by measuring the specific energy loss (dE/dx) along the muon's path and relating the dE/dx to the muon energy. Because high-energy muons (E_mu > 1 TeV) lose energy randomly, the spread in dE/dx values is quite large, leading to a typical energy resolution of 0.29 in log10(E_mu) for a muon observed over a 1 km path length in the IceCube detector. In this paper, we present an improved method that uses a truncated mean and other techniques to determine the muon energy. The muon track is divided into separate segments with individual dE/dx values. The elimination of segments with the highest dE/dx results in an overall dE/dx that is more closely correlated to the muon energy. This method results in an energy resolution of 0.22 in log10(E_mu), which gives a 26% improvement. This technique is applicable to any large water or ice detector and potentially to large scintillator or liquid argon detectors.Comment: 12 pages, 16 figure

    All-particle cosmic ray energy spectrum measured with 26 IceTop stations

    Full text link
    We report on a measurement of the cosmic ray energy spectrum with the IceTop air shower array, the surface component of the IceCube Neutrino Observatory at the South Pole. The data used in this analysis were taken between June and October, 2007, with 26 surface stations operational at that time, corresponding to about one third of the final array. The fiducial area used in this analysis was 0.122 km^2. The analysis investigated the energy spectrum from 1 to 100 PeV measured for three different zenith angle ranges between 0{\deg} and 46{\deg}. Because of the isotropy of cosmic rays in this energy range the spectra from all zenith angle intervals have to agree. The cosmic-ray energy spectrum was determined under different assumptions on the primary mass composition. Good agreement of spectra in the three zenith angle ranges was found for the assumption of pure proton and a simple two-component model. For zenith angles {\theta} < 30{\deg}, where the mass dependence is smallest, the knee in the cosmic ray energy spectrum was observed between 3.5 and 4.32 PeV, depending on composition assumption. Spectral indices above the knee range from -3.08 to -3.11 depending on primary mass composition assumption. Moreover, an indication of a flattening of the spectrum above 22 PeV were observed.Comment: 38 pages, 17 figure

    Development of a patient decision aid for patients with breast cancer who consider immediate breast reconstruction after mastectomy

    Get PDF
    Purpose The aim of this study was to develop a patient decision aid (pDA) that could support patients with breast cancer (BC) in making an informed decision about breast reconstruction (BR) after mastectomy. Methods The development included four stages: (i) Establishment of a multidisciplinary team; (ii) Needs assessment consisting of semi-structured interviews in patients and a survey among healthcare professionals (HCPs); (iii) Creation of content, design and technical system; and (iv) Acceptability and usability testing using a think-aloud approach in patients and interviews among HCPs and representatives of the Dutch Breast Cancer Patient Organization. Results From the needs assessment, three themes were identified: Challenging period to make a decision, Diverse motivations for a personal decision and Information needed to make a decision about BR. HCPs valued the development of a pDA, especially to prepare patients for consultation. The pDA that was developed contained three parts: first, a consultation sheet for oncological breast surgeons to introduce the choice; second, an online tool including an overview of reconstructive options, the pros and cons of each option, information on the consequences of each option for daily life, exercises to clarify personal values and patient stories; and third, a summary sheet with patients' values, preferences and questions to help inform and guide the discussion between the patient and her plastic surgeon. The pDA was perceived to be informative, helpful and easy to use by patients and HCPs. Conclusion Consistent with information needs, a pDA was developed to support patients with BC who consider immediate BR in making an informed decision together with their plastic surgeon. Patient or Public Contribution Patients participated in the needs assessment and in acceptability and usability testing.Hereditary cancer genetic

    Decisional conflict in breast cancer patients considering immediate breast reconstruction

    Get PDF
    Background: Breast cancer (BC) patients who are treated with mastectomy are frequently offered immediate breast reconstruction. This study aimed to assess decisional conflict in patients considering immediate breast reconstruction, and to identify factors associated with clinically significant decisional conflict (CSDC).Methods: Baseline data of a multicenter randomized controlled trial evaluating the impact of an online decision aid for BC patients considering immediate breast reconstruction after mastectomy were analyzed. Participants completed questionnaires assessing sociodemographic and clinical characteristics, decisional conflict and other patient-reported outcomes related to decision-making such as breast reconstruction preference, knowledge, information resources used, preferred involvement in decision-making, information coping style, and anxiety. Multivariable logistic regression analysis was performed to identify factors associated with CSDC (score > 37.5 on decisional conflict).Results: Of the 250 participants, 68% experienced CSDC. Patients with a slight preference for breast reconstruction (odds ratio (OR) = 6.19, p Conclusion: A majority of BC patients who consider immediate breast reconstruction after mastectomy experience clinically significant decisional conflict. The findings emphasize the need for decision support, especially for patients who do not have a strong preference for breast reconstruction.Hereditary cancer genetic

    Neutrino oscillation studies with IceCube-DeepCore

    Get PDF
    AbstractIceCube, a gigaton-scale neutrino detector located at the South Pole, was primarily designed to search for astrophysical neutrinos with energies of PeV and higher. This goal has been achieved with the detection of the highest energy neutrinos to date. At the other end of the energy spectrum, the DeepCore extension lowers the energy threshold of the detector to approximately 10 GeV and opens the door for oscillation studies using atmospheric neutrinos. An analysis of the disappearance of these neutrinos has been completed, with the results produced being complementary with dedicated oscillation experiments. Following a review of the detector principle and performance, the method used to make these calculations, as well as the results, is detailed. Finally, the future prospects of IceCube-DeepCore and the next generation of neutrino experiments at the South Pole (IceCube-Gen2, specifically the PINGU sub-detector) are briefly discussed

    A muon-track reconstruction exploiting stochastic losses for large-scale Cherenkov detectors

    Get PDF
    IceCube is a cubic-kilometer Cherenkov telescope operating at the South Pole. The main goal of IceCube is the detection of astrophysical neutrinos and the identification of their sources. High-energy muon neutrinos are observed via the secondary muons produced in charge current interactions with nuclei in the ice. Currently, the best performing muon track directional reconstruction is based on a maximum likelihood method using the arrival time distribution of Cherenkov photons registered by the experiment\u27s photomultipliers. A known systematic shortcoming of the prevailing method is to assume a continuous energy loss along the muon track. However at energies >1 TeV the light yield from muons is dominated by stochastic showers. This paper discusses a generalized ansatz where the expected arrival time distribution is parametrized by a stochastic muon energy loss pattern. This more realistic parametrization of the loss profile leads to an improvement of the muon angular resolution of up to 20% for through-going tracks and up to a factor 2 for starting tracks over existing algorithms. Additionally, the procedure to estimate the directional reconstruction uncertainty has been improved to be more robust against numerical errors

    Formation of a reliable capsular flap in a rat model.

    No full text
    Contains fulltext : 53549.pdf (publisher's version ) (Closed access)Prefabrication can be used to produce capsular flaps; other researchers have confirmed the feasibility of such flaps. Before the possibilities of capsular flaps can be explored, a reliable method to create these flaps has to be established first. METHODS: To produce capsular flaps in a rat model, the femoral vascular bundle was sandwiched between two silicone sheets. Three different methods were used and described. The capsule that formed between the two silicone sheets receives its main blood supply from that vascular pedicle. In this way pedicled capsular flaps were created. These flaps were used as a carrier for a skin graft, thus pre-laminating them, to test their ability for reconstructive surgery. The results of the three different methods of creating capsular flaps in a rat model were described and their results were evaluated. Especially the amount of capsule formation and the viability of the skin grafts was observed and compared. The feasibility of pre-laminated capsular flaps is confirmed and the most reliable method of creating them is described
    • …
    corecore