149 research outputs found
Molecular testing for acute respiratory tract infections: clinical and diagnostic recommendations from the IDSA\u27s Diagnostics Committee.
The clinical signs and symptoms of acute respiratory tract infections (RTIs) are not pathogen specific. Highly sensitive and specific nucleic acid amplification tests have become the diagnostic reference standard for viruses and translation of bacterial assays from basic research to routine clinical practice represents an exciting advance in respiratory medicine. Most recently, molecular diagnostics have played an essential role in the global health response to the novel coronavirus pandemic. How best to use newer molecular tests for RTI in combination with clinical judNorthwell Healthnt and traditional methods can be bewildering given the plethora of available assays and rapidly evolving technologies. Here, we summarize the current state of the art with respect to the diagnosis of viral and bacterial RTIs, provide a practical framework for diagnostic decision-making using selected patient-centered vignettes, and make recommendations for future studies to advance the field
Advancing diagnostics to address antibacterial resistance: The diagnostics and devices committee of the Antibacterial Resistance Leadership Group
Diagnostics are a cornerstone of the practice of infectious diseases. However, various limitations frequently lead to unmet clinical needs. In most other domains, diagnostics focus on narrowly defined questions, provide readily interpretable answers, and use true gold standards for development. In contrast, infectious diseases diagnostics must contend with scores of potential pathogens, dozens of clinical syndromes, emerging pathogens, rapid evolution of existing pathogens and their associated resistance mechanisms, and the absence of gold standards in many situations. In spite of these challenges, the importance and value of diagnostics cannot be underestimated. Therefore, the Antibacterial Resistance Leadership Group has identified diagnostics as 1 of 4 major areas of emphasis. Herein, we provide an overview of that development, highlighting several examples where innovation in study design, content, and execution is advancing the field of infectious diseases diagnostics
Titration-free massively parallel pyrosequencing using trace amounts of starting material
Continuous efforts have been made to improve next-generation sequencing methods for increased robustness and for applications on low amounts of starting material. We applied double-stranded library protocols for the Roche 454 platform to avoid the yield-reducing steps associated with single-stranded library preparation, and applied a highly sensitive Taqman MGB-probe-based quantitative polymerase chain reaction (qPCR) method. The MGB-probe qPCR, which can detect as low as 100 copies, was used to quantify the amount of effective library, i.e. molecules that form functional clones in emulsion PCR. We also demonstrate that the distribution of library molecules on capture beads follows a Poisson distribution. Combining the qPCR and Poisson statistics, the labour-intensive and costly titration can be eliminated and trace amounts of starting material such as precious clinical samples, transcriptomes of small tissue samples and metagenomics on low biomass environments is applicable
A high-resolution melt curve toolkit to identify lineage-defining SARS-CoV-2 mutations.
The emergence of severe acute respiratory syndrome 2 (SARS-CoV-2) variants of concern (VOCs), with mutations linked to increased transmissibility, vaccine escape and virulence, has necessitated the widespread genomic surveillance of SARS-CoV-2. This has placed a strain on global sequencing capacity, especially in areas lacking the resources for large scale sequencing activities. Here we have developed three separate multiplex high-resolution melting assays to enable the identification of Alpha, Beta, Delta and Omicron VOCs. The assays were evaluated against whole genome sequencing on upper-respiratory swab samples collected during the Alpha, Delta and Omicron [BA.1] waves of the UK pandemic. The sensitivities of the eight individual primer sets were all 100%, and specificity ranged from 94.6 to 100%. The multiplex HRM assays have potential as a tool for high throughput surveillance of SARS-CoV-2 VOCs, particularly in areas with limited genomics facilities
Reference Intervals in Healthy Adult Ugandan Blood Donors and Their Impact on Conducting International Vaccine Trials
BACKGROUND: Clinical trials are increasingly being conducted internationally. In order to ensure enrollment of healthy participants and proper safety evaluation of vaccine candidates, established reference intervals for clinical tests are required in the target population. METHODOLOGY/PRINCIPAL FINDINGS: We report a reference range study conducted in Ugandan adult blood bank donors establishing reference intervals for hematology and clinical chemistry parameters. Several differences were observed when compared to previously established values from the United States, most notably in neutrophils and eosinophils. CONCLUSIONS/SIGNIFICANCE: In a recently conducted vaccine trial in Uganda, 31 percent (n = 69) of volunteers screened (n = 223) were excluded due to hematologic abnormalities. If local reference ranges had been employed, 83% of those screened out due to these abnormalities could have been included in the study, drastically reducing workload and cost associated with the screening process. In addition, toxicity tables used in vaccine and drug trial safety evaluations may need adjustment as some clinical reference ranges determined in this study overlap with grade 1 and grade 2 adverse events
Community participation for malaria elimination in tafea province, vanuatu: part ii. social and cultural aspects of treatment-seeking behaviour
Background: Early diagnosis and prompt effective case management are important components of any malaria elimination strategy. Tafea Province, Vanuatu has a rich history of traditional practices and beliefs, which have been integrated with missionary efforts and the introduction of modern constructions of health. Gaining a detailed knowledge of community perceptions of malarial symptomatology and treatment-seeking behaviours is essential in guiding effective community participation strategies for malaria control and elimination
Assessment of vitamin D intake among Libyan women - adaptation and validation of specific food frequency questionnaire
Vitamin D deficiency (VDD) has pandemic proportions worldwide. Numerous studies report on high prevalence of VDD in sunny regions like Near East and North Africa (NENA). Previous studies indicated that Libyan population was at risk of VDD. To contribute to the body of evidence, measurement of vitamin D status on children, adults, in Misurata region was conducted, and confirmed with validated dietary intake study. Serum 25(OH)D was analysed using electrochemiluminescence protein binding assay. Existing Food Frequency Questionnaires (FFQ) were adapted to Libyan Women Food Frequency Questionnaire (LW-FFQ). Repeated 24h dietary recalls and LW-FFQ were employed in vitamin D intake evaluation. LW-FFQ was validated using 24h dietary recall and vitamin D status as referent methods. The questionnaires included anthropometry and lifestyle information. Vitamin D status assessment revealed inadequate levels (25(OH)D lt 50nmol/l) in almost 80% of participants. Women (25-64y) were identified as the most vulnerable group with vitamin D inadequacy present in 82% (61.6% had 25(OH)D lt 25nmol/l, and 20.2% had 25-50nmol/l 25(OH)D). Average Vitamin D intake within the study sample (n=316) was 3.9 +/- 7.9 mu g/d, with 92% participants below both Institute of Medicine (IOM) (10 mu g/d) and European Food Safety Authority (15 mu g/d) recommendations. Measured vitamin D status, in 13% of this group, correlated significantly (p=0.015) with intake estimates. Based on self-report, consumption of vitamin D supplements does not exist among study participants. Additional lifestyle factors influencing vitamin D status were analysed. Only 2% of study participants spend approximately 11 min on the sun daily, 60.4% were obese, 23.1% were overweight and 71.2% reported low physical activity. These findings confirm previous reports on high prevalence of VDD in women across NENA, and in Libya. The situation calls for multi-sectoral actions and public health initiatives to address dietary and lifestyle habits
Diagnostic performance of GENEDIA W and ActiveXpress+ COVID-19 antigens tests among symptomatic individuals in Peru and The United Kingdom
Objectives: In order to generate independent performance data regarding accuracy of COVID-19 antigen-based rapid diagnostic tests (Ag-RDTs), prospective diagnostic evaluation studies across multiple sites are required to evaluate their performance in different clinical settings. This report describes the clinical evaluation the GENEDIA W COVID-19 Ag Device (Green Cross Medical Science Corp., Chungbuk, Korea) and the ActiveXpress+ COVID-19 Complete Testing Kit (Edinburgh Genetics Ltd, UK), in two testing sites Peru and the United Kingdom.
Methods: Nasopharyngeal swabs collected from 456 symptomatic patients at primary points of care in Lima, Peru and 610 symptomatic participants at a COVID-19 Drive-Through testing site in Liverpool, England were analyzed by Ag-RDT and compared to RT-PCR. Analytical evaluation of both Ag-RDTs was assessed using serial dilutions of direct culture supernatant of a clinical SARS-CoV-2 isolate from the B.1.1.7 lineage.
Results: For GENEDIA brand, the values of overall sensitivity and specificity were 60.4% [95% CI 52.4–67.9%], and 99.2% [95% CI 97.6–99.7%] respectively; and for Active Xpress+ the overall values of sensitivity and specificity were 66.2% [95% CI 54.0–76.5%], and 99.6% [95% CI 97.9–99.9%] respectively. The analytical limit of detection was determined at 5.0 x 102 pfu/ml what equals to approximately 1.0 x 104 gcn/ml for both Ag-RDTs. The UK cohort had lower median Ct values compared to that of Peru during both evaluations. When split by Ct, both Ag-RDTs had optimum sensitivities at Ct<20 (in Peru; 95% [95% CI 76.4–99.1%] and 100.0% [95% CI 74.1–100.0%] and in the UK; 59.2% [95% CI 44.2–73.0%] and 100.0% [95% CI 15.8–100.0%], for the GENDIA and the ActiveXpress+, respectively).
Conclusions: Whilst the overall clinical sensitivity of the Genedia did not meet WHO minimum performance requirements for rapid immunoassays in either cohort, the ActiveXpress+ did so for the small UK cohort. This study illustrates comparative performance of Ag-RDTs across two global settings and considers the different approaches in evaluation methods
Development, validation and evaluation of a rapid PCR-nucleic acid lateral flow immuno-assay for the detection of Plasmodium and the differentiation between Plasmodium falciparum and Plasmodium vivax
Faecal immunochemical tests to triage patients with lower abdominal symptoms for suspected colorectal cancer referrals in primary care: a systematic review and cost-effectiveness analysis
- …
