287 research outputs found

    Screening for infectious diseases

    Get PDF
    Introduction: Fetal brain injury is an essential cause of lifelong morbidity. Infection appears as a cause of brain damage. Apart from chorioamnionitis, screening for infectious diseases must be considered in pregnancies with a risk of congenital infection or cases with abnormal cerebral ultrasound findings. Discussion: Congenital infections include most of the major components of the TORCH complex: toxoplasmosis, rubella, cytomegalovirus, herpes, and varicella. Seronegative mothers can develop primary infection, which carries a risk of vertical transmission. The timing of the infection is a critical point, because fetal damage often depends on the gestational age at which acute maternal infection took place and occurs more likely in the first half of pregnancy. Antenatal ultrasound can detect brain abnormalities, like hydrocephalus, periventricular leukomalacia, calcifications or hemorrhage. Maternal serologic tests must be performed to look for an infectious etiology; the most frequent agents are the components of the TORCH complex. But additional serology must include parvovirus B19, HIV, and coxsackieviruse

    Detection of Ureaplasma urealyticum in Second-Trimester Amniotic Fluid by Polymerase Chain Reaction Correlates with Subsequent Preterm Labor and Delivery

    Get PDF
    Ureaplasma urealyticum is the microorganism most frequently isolated from the amniotic fluid of women in preterm labor. The relationship between intra-amniotic U. urealyticum in healthy second-trimester pregnant women and subsequent pregnancy outcome was investigated. Transabdominal amniotic fluid obtained from 254 asymptomatic women at 15-17 weeks' gestation were tested by polymerase chain reaction (PCR). U. urealyticum was identified in 29 subjects (11.4%). A subsequent preterm labor occurred in 17 U. urealyticum-positive women (58.6%), compared with 10 (4.4%) U. urealyticum-negative women (P<.0001). Preterm birth was documented in 7 (24.1%) U. urealyticum-positive women compared with only 1 U. urealyticum-negative woman (0.4%) (P<.0001). U. urealyticum-positive women also had a higher prevalence of preterm labor in a prior pregnancy (20.7%) than did the negative women (2.7%; P=.0008). PCR testing of second-trimester amniotic fluid for U. urealyticum can identify women at risk for subsequent preterm labor and deliver

    Pelvic floor dysfunction 6 years post-anal sphincter tear at the time of vaginal delivery

    Get PDF
    Introduction and hypothesis: This study aims to estimate fecal, urinary incontinence, and sexual function 6 years after an obstetrical anal sphincter tear. Methods: Among 13,213 women who had a vaginal delivery of a cephalic singleton at term, 196 women sustained an anal sphincter tear. They were matched to 588 controls. Validated questionnaires grading fecal and urinary incontinence, and sexual dysfunction were completed by the participants. Results: Severe fecal incontinence was more frequently reported by women who had sustained an anal sphincter tear compared to the controls. Women with an anal sphincter tear had no increased risk of urinary incontinence, but reported significantly more pain, difficulty with vaginal lubrication, and difficulty achieving orgasm compared to the controls. A fetal occiput posterior position during childbirth was an independent risk factor for both severe urinary incontinence and severe sexual dysfunction. Conclusions: Fecal incontinence is strongly associated with an anal sphincter tear. A fetal occiput posterior position represents a risk factor for urinary incontinence and sexual dysfunctio

    Piezofibre composite transducers for next generation 3D USCT

    Get PDF
    At the Karlsruhe Institue of Technology (KIT), a 3D-Ultrasound Computer Tomography (3D-USCT) medical imaging system for early breast cancer detection is currently developed. With the next generation of 3D-USCT 2.5, the current region of interest (ROI) of 10 x 10 x 10 cm³ shall be increased to 20 x 20 x 20 cm³ to allow reliable imaging results also for bigger female breasts. Therefore, the opening angle (OA) of the future transducers should be increased to approx. 60 ° at 3 dB while other characteristics such as bandwidth (BW) and resonance frequency should be preserved or even improved. Based on Fraunhofer IKTS Piezofibre composites utilized for transducer production, an optimization is performed on piezoelectric sensor geometry and size, type and structure of matching and backing layer and interconnection technology of the several parts of the transduce

    Effect of natalizumab on disease progression in secondary progressive multiple sclerosis (ASCEND). a phase 3, randomised, double-blind, placebo-controlled trial with an open-label extension

    Get PDF
    Background: Although several disease-modifying treatments are available for relapsing multiple sclerosis, treatment effects have been more modest in progressive multiple sclerosis and have been observed particularly in actively relapsing subgroups or those with lesion activity on imaging. We sought to assess whether natalizumab slows disease progression in secondary progressive multiple sclerosis, independent of relapses. Methods: ASCEND was a phase 3, randomised, double-blind, placebo-controlled trial (part 1) with an optional 2 year open-label extension (part 2). Enrolled patients aged 18–58 years were natalizumab-naive and had secondary progressive multiple sclerosis for 2 years or more, disability progression unrelated to relapses in the previous year, and Expanded Disability Status Scale (EDSS) scores of 3·0–6·5. In part 1, patients from 163 sites in 17 countries were randomly assigned (1:1) to receive 300 mg intravenous natalizumab or placebo every 4 weeks for 2 years. Patients were stratified by site and by EDSS score (3·0–5·5 vs 6·0–6·5). Patients completing part 1 could enrol in part 2, in which all patients received natalizumab every 4 weeks until the end of the study. Throughout both parts, patients and staff were masked to the treatment received in part 1. The primary outcome in part 1 was the proportion of patients with sustained disability progression, assessed by one or more of three measures: the EDSS, Timed 25-Foot Walk (T25FW), and 9-Hole Peg Test (9HPT). The primary outcome in part 2 was the incidence of adverse events and serious adverse events. Efficacy and safety analyses were done in the intention-to-treat population. This trial is registered with ClinicalTrials.gov, number NCT01416181. Findings: Between Sept 13, 2011, and July 16, 2015, 889 patients were randomly assigned (n=440 to the natalizumab group, n=449 to the placebo group). In part 1, 195 (44%) of 439 natalizumab-treated patients and 214 (48%) of 448 placebo-treated patients had confirmed disability progression (odds ratio [OR] 0·86; 95% CI 0·66–1·13; p=0·287). No treatment effect was observed on the EDSS (OR 1·06, 95% CI 0·74–1·53; nominal p=0·753) or the T25FW (0·98, 0·74–1·30; nominal p=0·914) components of the primary outcome. However, natalizumab treatment reduced 9HPT progression (OR 0·56, 95% CI 0·40–0·80; nominal p=0·001). In part 1, 100 (22%) placebo-treated and 90 (20%) natalizumab-treated patients had serious adverse events. In part 2, 291 natalizumab-continuing patients and 274 natalizumab-naive patients received natalizumab (median follow-up 160 weeks [range 108–221]). Serious adverse events occurred in 39 (13%) patients continuing natalizumab and in 24 (9%) patients initiating natalizumab. Two deaths occurred in part 1, neither of which was considered related to study treatment. No progressive multifocal leukoencephalopathy occurred. Interpretation: Natalizumab treatment for secondary progressive multiple sclerosis did not reduce progression on the primary multicomponent disability endpoint in part 1, but it did reduce progression on its upper-limb component. Longer-term trials are needed to assess whether treatment of secondary progressive multiple sclerosis might produce benefits on additional disability components. Funding: Biogen

    Search for Neutral Higgs Bosons in Events with Multiple Bottom Quarks at the Tevatron

    Get PDF
    The combination of searches performed by the CDF and D0 collaborations at the Fermilab Tevatron Collider for neutral Higgs bosons produced in association with b quarks is reported. The data, corresponding to 2.6 fb-1 of integrated luminosity at CDF and 5.2 fb-1 at D0, have been collected in final states containing three or more b jets. Upper limits are set on the cross section multiplied by the branching ratio varying between 44 pb and 0.7 pb in the Higgs boson mass range 90 to 300 GeV, assuming production of a narrow scalar boson. Significant enhancements to the production of Higgs bosons can be found in theories beyond the standard model, for example in supersymmetry. The results are interpreted as upper limits in the parameter space of the minimal supersymmetric standard model in a benchmark scenario favoring this decay mode.Comment: 10 pages, 2 figure

    Search for the standard model Higgs boson decaying to a bbˉb\bar{b} pair in events with no charged leptons and large missing transverse energy using the full CDF data set

    Get PDF
    We report on a search for the standard model Higgs boson produced in association with a vector boson in the full data set of proton-antiproton collisions at s=1.96\sqrt{s} = 1.96 TeV recorded by the CDF II detector at the Tevatron, corresponding to an integrated luminosity of 9.45 fb1^{-1}. We consider events having no identified charged lepton, a transverse energy imbalance, and two or three jets, of which at least one is consistent with originating from the decay of a bb quark. We place 95% credibility level upper limits on the production cross section times standard model branching fraction for several mass hypotheses between 90 and 150GeV/c2150 \mathrm{GeV}/c^2. For a Higgs boson mass of 125GeV/c2125 \mathrm{GeV}/c^2, the observed (expected) limit is 6.7 (3.6) times the standard model prediction.Comment: Accepted by Phys. Rev. Let

    Search for the standard model Higgs boson decaying to a bb pair in events with one charged lepton and large missing transverse energy using the full CDF data set

    Get PDF
    We present a search for the standard model Higgs boson produced in association with a W boson in sqrt(s) = 1.96 TeV p-pbar collision data collected with the CDF II detector at the Tevatron corresponding to an integrated luminosity of 9.45 fb-1. In events consistent with the decay of the Higgs boson to a bottom-quark pair and the W boson to an electron or muon and a neutrino, we set 95% credibility level upper limits on the WH production cross section times the H->bb branching ratio as a function of Higgs boson mass. At a Higgs boson mass of 125 GeV/c2 we observe (expect) a limit of 4.9 (2.8) times the standard model value.Comment: Submitted to Phys. Rev. Lett (v2 contains clarifications suggested by PRL

    Search for the standard model Higgs boson decaying to a bb pair in events with two oppositely-charged leptons using the full CDF data set

    Get PDF
    We present a search for the standard model Higgs boson produced in association with a Z boson in data collected with the CDF II detector at the Tevatron, corresponding to an integrated luminosity of 9.45/fb. In events consistent with the decay of the Higgs boson to a bottom-quark pair and the Z boson to electron or muon pairs, we set 95% credibility level upper limits on the ZH production cross section times the H -> bb branching ratio as a function of Higgs boson mass. At a Higgs boson mass of 125 GeV/c^2 we observe (expect) a limit of 7.1 (3.9) times the standard model value.Comment: To be submitted to Phys. Rev. Let

    Women and healthcare providers' perceptions of a midwife-led unit in a Swiss university hospital: a qualitative study.

    Get PDF
    BACKGROUND: The development of medical-led care in obstetrics over the past decades has contributed to improving outcomes for both mother and child. Although efficiency has improved in complex situations, unnecessary interventions are still practiced in low-risk pregnancies, contrary to international recommendations. A shift to a less interventionist model of care has encouraged many countries to review their policies on maternal health care and develop models such as the "midwife-led unit" (MLU) where the midwife plays a predominant role with a minimum of routine intervention. Existing research has provided convincing evidence that MLUs lead to better maternal and neonatal outcomes when compared to traditional models. They not only improve the level of satisfaction amongst women, but are also associated with reduced healthcare costs. This study aimed to explore the perceptions of women and healthcare providers regarding the creation of an MLU in a Swiss university hospital. METHODS: A descriptive research study using qualitative methods was conducted among pregnant women and new mothers in a Swiss maternity unit, including also midwives and medical staff. Data collection was carried out through one-to-one interviews, focus groups, and telephone interviews (n = 63). After transcription, thematic analysis was performed. RESULTS: The triangulation of perceptions of women and healthcare providers indicated support for the implementation of an MLU to promote physiological delivery. Most women welcomed the idea of an MLU, in particular how it could help in offering continuity of care. Healthcare providers were optimistic about the implementation of an MLU and recognised the need for some women to have access to a less interventionist approach. From the women's perspective, barriers concerned the lack of awareness of midwives' full scope of practice, while barriers for midwives and obstetricians were related to the challenge to develop a good interprofessional collaboration. CONCLUSION: Alternative models to provide maternity care for low-risk women have been developed and evaluated widely in several countries outside Switzerland. This study showed that women and healthcare providers were favourable towards the development of a new care model, while taking into account the specific expectations and barriers raised by participants
    corecore