3,765 research outputs found
Clinical Management of Neuroendocrine Neoplasms in Clinical Practice: A Formal Consensus Exercise
Many treatment approaches are now available for neuroendocrine neoplasms (NENs). While several societies have issued guidelines for diagnosis and treatment of NENs, there are still areas of controversy for which there is limited guidance. Expert opinion can thus be of support where firm recommendations are lacking. A group of experts met to formulate 14 statements relative to diagnosis and treatment of NENs and presented herein. The nominal group and estimate-talk-estimate techniques were used. The statements covered a broad range of topics from tools for diagnosis to follow-up, evaluation of response, treatment efficacy, therapeutic sequence, and watchful waiting. Initial prognostic characterization should be based on clinical information as well as histopathological analysis and morphological and functional imaging. It is also crucial to optimize RLT for patients with a NEN starting from accurate characterization of the patient and disease. Follow-up should be patient/tumor tailored with a shared plan about timing and type of imaging procedures to use to avoid safety issues. It is also stressed that patient-reported outcomes should receive greater attention, and that a multidisciplinary approach should be mandatory. Due to the clinical heterogeneity and relative lack of definitive evidence for NENs, personalization of diagnostic–therapeutic work-up is crucial
We only die once... but from how many causes?
Analysing causes of death provides a betterunderstanding of long-term mortality trends. InFrance, the death certificates completed by physiciansgenerally mention several causes of death (2.4 onaverage in 2011). As a general rule, just one of them,the so-called underlying cause, is taken into account.As a result, the contribution of certain diseases-endocrine diseases for example-to mortality isseverely underestimated. In a context of rising lifeexpectancy where people increasingly die not from asingle cause of death but from several, it is importantto also take these contributing causes into account
Performance of the LHCb vertex locator
The Vertex Locator (VELO) is a silicon microstrip detector that surrounds the proton-proton interaction region in the LHCb experiment. The performance of the detector during the first years of its physics operation is reviewed. The system is operated in vacuum, uses a bi-phase CO2 cooling system, and the sensors are moved to 7 mm from the LHC beam for physics data taking. The performance and stability of these characteristic features of the detector are described, and details of the material budget are given. The calibration of the timing and the data processing algorithms that are implemented in FPGAs are described. The system performance is fully characterised. The sensors have a signal to noise ratio of approximately 20 and a best hit resolution of 4 μm is achieved at the optimal track angle. The typical detector occupancy for minimum bias events in standard operating conditions in 2011 is around 0.5%, and the detector has less than 1% of faulty strips. The proximity of the detector to the beam means that the inner regions of the n+-on-n sensors have undergone space-charge sign inversion due to radiation damage. The VELO performance parameters that drive the experiment's physics sensitivity are also given. The track finding efficiency of the VELO is typically above 98% and the modules have been aligned to a precision of 1 μm for translations in the plane transverse to the beam. A primary vertex resolution of 13 μm in the transverse plane and 71 μm along the beam axis is achieved for vertices with 25 tracks. An impact parameter resolution of less than 35 μm is achieved for particles with transverse momentum greater than 1 GeV/c
Precision luminosity measurements at LHCb
Measuring cross-sections at the LHC requires the luminosity to be determined accurately at each centre-of-mass energy √s. In this paper results are reported from the luminosity calibrations carried out at the LHC interaction point 8 with the LHCb detector for √s = 2.76, 7 and 8 TeV (proton-proton collisions) and for √sNN = 5 TeV (proton-lead collisions). Both the "van der Meer scan" and "beam-gas imaging" luminosity calibration methods were employed. It is observed that the beam density profile cannot always be described by a function that is factorizable in the two transverse coordinates. The introduction of a two-dimensional description of the beams improves significantly the consistency of the results. For proton-proton interactions at √s = 8 TeV a relative precision of the luminosity calibration of 1.47% is obtained using van der Meer scans and 1.43% using beam-gas imaging, resulting in a combined precision of 1.12%. Applying the calibration to the full data set determines the luminosity with a precision of 1.16%. This represents the most precise luminosity measurement achieved so far at a bunched-beam hadron collider
Observation of two new baryon resonances
Two structures are observed close to the kinematic threshold in the mass spectrum in a sample of proton-proton collision data, corresponding
to an integrated luminosity of 3.0 fb recorded by the LHCb experiment.
In the quark model, two baryonic resonances with quark content are
expected in this mass region: the spin-parity and
states, denoted and .
Interpreting the structures as these resonances, we measure the mass
differences and the width of the heavier state to be
MeV,
MeV,
MeV, where the first and second
uncertainties are statistical and systematic, respectively. The width of the
lighter state is consistent with zero, and we place an upper limit of
MeV at 95% confidence level. Relative
production rates of these states are also reported.Comment: 17 pages, 2 figure
Differential branching fraction and angular analysis of the decay B0→K∗0μ+μ−
The angular distribution and differential branching fraction of the decay B 0→ K ∗0 μ + μ − are studied using a data sample, collected by the LHCb experiment in pp collisions at s√=7 TeV, corresponding to an integrated luminosity of 1.0 fb−1. Several angular observables are measured in bins of the dimuon invariant mass squared, q 2. A first measurement of the zero-crossing point of the forward-backward asymmetry of the dimuon system is also presented. The zero-crossing point is measured to be q20=4.9±0.9GeV2/c4 , where the uncertainty is the sum of statistical and systematic uncertainties. The results are consistent with the Standard Model predictions
Observation of associated production of a boson with a meson in the~forward region
A search for associated production of a boson with an open charm meson is
presented using a data sample, corresponding to an integrated luminosity of
of proton--proton collisions at a centre-of-mass energy
of 7\,TeV, collected by the LHCb experiment. %% Seven candidate events for
associated production of a boson with a meson and four candidate
events for a boson with a meson are observed with a combined
significance of 5.1standard deviations. The production cross-sections in the
forward region are measured to be where the first uncertainty is statistical and the
second systematic.Comment: 18 pages, 2 figure
Measurements of the , , meson and baryon lifetimes
Measurements of -hadron lifetimes are reported using collision data,
corresponding to an integrated luminosity of 1.0fb, collected by the
LHCb detector at a centre-of-mass energy of Tev. Using the exclusive decays
, , ,
and the average decay
times in these modes are measured to be = 0.004 0.003 ps, =
0.006 0.004 ps, = 0.013
0.005 ps, = 0.027
0.006 ps and = 0.011
0.005 ps, where the first uncertainty is statistical and the second is
systematic. These represent the most precise lifetime measurements in these
decay modes. In addition, ratios of these lifetimes, and the ratio of the
decay-width difference, , to the average width, , in
the system, , are
reported. All quantities are found to be consistent with Standard Model
expectations.Comment: 28 pages, 4 figures. Updated reference
Precision measurement of violation in decays
The time-dependent asymmetry in decays is
measured using collision data, corresponding to an integrated luminosity
of fb, collected with the LHCb detector at centre-of-mass energies
of and TeV. In a sample of 96 000 decays, the
-violating phase is measured, as well as the decay widths
and of the light and heavy mass eigenstates of the
system. The values obtained are rad, ps, andps, where the first uncertainty is
statistical and the second systematic. These are the most precise single
measurements of those quantities to date. A combined analysis with decays gives rad. All
measurements are in agreement with the Standard Model predictions. For the
first time the phase is measured independently for each polarisation
state of the system and shows no evidence for polarisation
dependence.Comment: 6 figure
Measurement of the ratio of branching fractions BR(B0 -> K*0 gamma)/BR(Bs0 -> phi gamma)
The ratio of branching fractions of the radiative B decays B0 -> K*0 gamma
and Bs0 -> phi gamma has been measured using 0.37 fb-1 of pp collisions at a
centre of mass energy of sqrt(s) = 7 TeV, collected by the LHCb experiment. The
value obtained is BR(B0 -> K*0 gamma)/BR(Bs0 -> phi gamma) = 1.12 +/- 0.08
^{+0.06}_{-0.04} ^{+0.09}_{-0.08}, where the first uncertainty is statistical,
the second systematic and the third is associated to the ratio of fragmentation
fractions fs/fd. Using the world average for BR(B0 -> K*0 gamma) = (4.33 +/-
0.15) x 10^{-5}, the branching fraction BR(Bs0 -> phi gamma) is measured to be
(3.9 +/- 0.5) x 10^{-5}, which is the most precise measurement to date.Comment: 15 pages, 1 figure, 2 table
- …