761 research outputs found

    Reference values for spirometry and their use in test interpretation: A Position Statement from the Australian and New Zealand Society of Respiratory Science

    Get PDF
    Traditionally, spirometry testing tended to be confined to the realm of hospital-based laboratories but is now performed in a variety of health care settings. Regardless of the setting in which the test is conducted, the fundamental basis of spirometry is that the test is both performed and interpreted according to the international standards. The purpose of this Australian and New Zealand Society of Respiratory Science (ANZSRS) statement is to provide the background and recommendations for the interpretation of spirometry results in clinical practice. This includes the benchmarking of an individual's results to population reference data, as well as providing the platform for a statistically and conceptually based approach to the interpretation of spirometry results. Given the many limitations of older reference equations, it is imperative that the most up-to-date and relevant reference equations are used for test interpretation. Given this, the ANZSRS recommends the adoption of the Global Lung Function Initiative (GLI) 2012 spirometry reference values throughout Australia and New Zealand. The ANZSRS also recommends that interpretation of spirometry results is based on the lower limit of normal from the reference values and the use of Z-scores where available

    Production of ceramics from coal fly ash

    Get PDF
    Dense ceramics are produced from fly ash from REK Bitola, Republic of Macedonia. Four types of fly ash from electro filters and one from the collected zone with particles < 0.063 mm were the subject of this research. Consolidation was achieved by pressing (P= 133 MPa) and sintering (950, 1000, 1050 and 11000C and heating rates of 3 and 100/min). Densification was realized by liquid phase sintering and solid state reaction where diopside [Ca(Mg,Al)(Si,Al)2O6] was formed. Ceramics with optimal properties (porosity 2.96±0.5%, bending strength - 47.01±2 MPa, compressive strength - 170 ±5 MPa) was produced at 1100ºC using the heating rate of 10ºC/min

    Evaluation of the global lung function initiative 2012 reference values for spirometry in a Swedish population sample

    Get PDF
    Background: The Global Lung Function Initiative 2012 (GLI) reference values are currently endorsed by several respiratory societies but evaluations of applicability for adults resident in European countries are lacking. The aim of this study was to evaluate if the GLI reference values are appropriate for an adult Caucasian Swedish population. Methods: During 2008-2013, clinical examinations including spirometry were performed on general population samples in northern Sweden, in which 501 healthy Caucasian non-smokers were identified. Predicted GLI reference values and Z-scores were calculated for each healthy non-smoking subject and the distributions and mean values for FEV1, FVC and the FEV1/FVC ratio were examined. The prevalence of airway obstruction among these healthy non-smokers was calculated based on the Lower Limit of normal (LLN) criterion (lower fifth percentile) for the FEV1/FVC ratio. Thus, by definition, a prevalence of 5% was expected. Results: The Z-scores for FEV1, FVC and FEV1/FVC were reasonably, although not perfectly, normally distributed, but not centred on zero. Both predicted FEV1 and, in particular, FVC were lower compared to the observed values in the sample. The deviations were greater among women compared to men. The prevalence of airway obstruction based on the LLN criterion for the FEV1/FVC ratio was 9.4% among women and 2.7% among men. Conclusions: The use of the GLI reference values may produce biased prevalence estimates of airway obstruction in Sweden, especially among women. These results demonstrate the importance of validating the GLI reference values in different countries.Peer reviewe

    Effect of spirometry on intra-thoracic pressures

    Get PDF
    Due to the high intra-thoracic pressures associated with forced vital capacity manoeuvres, spirometry is contraindicated for vulnerable patients. However, the typical pressure response to spirometry has not been reported. Eight healthy, recreationally-active men performed spirometry while oesophageal pressure was recorded using a latex balloon-tipped catheter. Peak oesophageal pressure during inspiration was - 47 ± 9 cmH O (37 ± 10% of maximal inspiratory pressure), while peak oesophageal pressure during forced expiration was 102 ± 34 cmH O (75 ± 17% of maximal expiratory pressure). The deleterious consequences of spirometry might be associated with intra-thoracic pressures that approach maximal values during forced expiration

    Smallest detectable change in volume differs between mass flow sensor and pneumotachograph

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To assess a pulmonary function change over time the mass flow sensor and the pneumotachograph are widely used in commercially available instruments. However, the smallest detectable change for both devices has never been compared. Therefore, the aim of this study is to determine the smallest detectable change in vital capacity (VC) and single-breath diffusion parameters measured by mass flow sensor and or pneumotachograph.</p> <p>Method</p> <p>In 28 healthy pulmonary function technicians VC, transfer factor for carbon monoxide (DLCO) and alveolar volume (VA) was repeatedly (10×) measured. The smallest detectable change was calculated by 1.96 x Standard Error of Measurement ×√2.</p> <p>Findings</p> <p>The mean (range) of the smallest detectable change measured by mass flow sensor and pneumotachograph respectively, were for VC (in Liter): 0.53 (0.46-0.65); 0.25 (0.17-0.36) (<it>p </it>= 0.04), DLCO (in mmol*kPa<sup>-1</sup>*min<sup>-1</sup>): 1.53 (1.26-1.7); 1.18 (0.84-1.39) (<it>p </it>= 0.07), VA (in Liter): 0.66. (0.53-0.82); 0.43 (0.34-0.53) (<it>p </it>= 0.04) and DLCO/VA (in mmol*kPa<sup>-1</sup>*min<sup>-1</sup>*L<sup>-1</sup>): 0.22 (0.19-0.28); 0.19 (0.14-0.22) (<it>p </it>= 0.79).</p> <p>Conclusions</p> <p>Smallest detectable significant change in VC and VA as measured by pneumotachograph are smaller than by mass flow sensor. Therefore, the pneumotachograph is the preferred instrument to estimate lung volume change over time in individual patients.</p

    COPD diagnosis related to different guidelines and spirometry techniques

    Get PDF
    The aim was to compare the diagnosis of COPD among smokers according to different international guidelines and to compare the outcome when using slow (SVC) and forced vital capacity (FVC)

    Reduction in membrane component of diffusing capacity is associated with the extent of acute pulmonary embolism

    Get PDF
    Acute pulmonary embolism (PE) often decreases pulmonary diffusing capacity for carbon monoxide (DL,CO), but data on the mechanisms involved are inconsistent. We wanted to investigate whether reduction in diffusing capacity of alveolo-capillary membrane (DM) and pulmonary capillary blood volume (Vc) is associated with the extent of PE or the presence and severity of right ventricular dysfunction (RVD) induced by PE and how the possible changes are corrected after 7-month follow-up. Forty-seven patients with acute non-massive PE in spiral computed tomography (CT) were included. The extent of PE was assessed by scoring mass of embolism. DL,CO, Vc, DM and alveolar volume (VA) were measured by using a single breath method with carbon monoxide and oxygen both at the acute phase and 7 months later. RVD was evaluated with transthoracic echocardiography and electrocardiogram. Fifteen healthy subjects were included as controls. DL,CO, DL, CO/VA, DM, vital capacity (VC) and VA were significantly lower in the patients with acute PE than in healthy controls (P<0·001). DM/Vc relation was significantly lower in patients with RVD than in healthy controls (P = 0·004). DM correlated inversely with central mass of embolism (r = −0·312; P = 0·047) whereas Vc did not. DM, DL,CO, VC and VA improved significantly within 7 months. In all patients (P = 0·001, P = 0·001) and persistent RVD (P = 0·020, P = 0·012), DM and DL,CO remained significantly lower than in healthy controls in the follow-up. DM was inversely related to central mass of embolism. Reduction in DM mainly explains the sustained decrease in DL,CO in PE after 7 months despite modern treatment of PE

    Global lung function initiative 2012 reference values for spirometry in Asian Americans

    Get PDF
    Background Spirometry reference values specifically designed for Asian Americans are currently unavailable. The performance of Global Lung Function Initiative 2012 (GLI-2012) equations on assessing spirometry in Asian Americans has not been evaluated. This study aimed to assess the fitness of relevant GLI-2012 equations for spirometry in Asian Americans. Methods Asian subjects who never smoked and had qualified spirometry data were extracted from the National Health and Nutrition Examination Survey (NHANES) 2011–2012. Z-scores of forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), and FEV1/FVC were separately constructed with GLI-2012 equations for North East (NE) Asians, South East (SE) Asians, and individuals of mixed ethnic origin (Mixed). In addition, Proportions of subjects with observed spirometry data below the lower limit of normal (LLN) were also evaluated on each GLI-2012 equation of interest. Results This study included 567 subjects (250 men and 317 women) aged 6–79 years. Spirometry z-scores (z-FEV1, z-FVC, and z-FEV1/FVC) based on GLI-2012 Mixed equations had mean values close to zero (− 0.278 to − 0.057) and standard deviations close to one (1.001 to 1.128); additionally, 6.0% (95% confidence interval (CI) 3.1–8.9%) and 6.4% (95% CI 3.7–9.1%) of subjects were with observed data below LLN for FEV1/FVC in men and women, respectively. In contrast, for NE Asian equations, all mean values of z-FEV1 and z-FVC were smaller than − 0.5; for SE Asian equations, mean values of z-FEV1/FVC were significantly smaller than zero in men (− 0.333) and women (− 0.440). Conclusions GLI-2012 equations for individuals of mixed ethnic origin adequately fitted spirometry data in this sample of Asian Americans. Future studies with larger sample sizes are needed to confirm these findings

    Predictive significance of the six-minute walk distance for long-term survival in chronic hypercapnic respiratory failure

    Get PDF
    Background: The 6-min walk distance ( 6-MWD) is a global marker of functional capacity and prognosis in chronic obstructive pulmonary disease ( COPD), but less explored in other chronic respiratory diseases. Objective: To study the role of 6-MWD in chronic hypercapnic respiratory failure ( CHRF). Methods: In 424 stable patients with CHRF and non-invasive ventilation ( NIV) comprising COPD ( n = 197), restrictive diseases ( RD; n = 112) and obesity-hypoventilation- syndrome ( OHS; n = 115), the prognostic value of 6-MWD for long- term survival was assessed in relation to that of body mass index (BMI), lung function, respiratory muscle function and laboratory parameters. Results: 6-MWD was reduced in patients with COPD ( median 280 m; quartiles 204/350 m) and RD ( 290 m; 204/362 m) compared to OHS ( 360 m; 275/440 m; p <0.001 each). Overall mortality during 24.9 (13.1/40.5) months was 22.9%. In the 424 patients with CHRF, 6-MWD independently predicted mortality in addition to BMI, leukocytes and forced expiratory volume in 1 s ( p <0.05 each). In COPD, 6-MWD was strongly associated with mortality using the median {[} p <0.001, hazard ratio ( HR) = 3.75, 95% confidence interval (CI): 2.24-6.38] or quartiles as cutoff levels. In contrast, 6-MWD was only significantly associated with impaired survival in RD patients when it was reduced to 204 m or less (1st quartile; p = 0.003, HR = 3.31, 95% CI: 1.73-14.10), while in OHS 6-MWD had not any prognostic value. Conclusions: In patients with CHRF and NIV, 6-MWD was predictive for long- term survival particularly in COPD. In RD only severely reduced 6-MWD predicted mortality, while in OHS 6-MWD was relatively high and had no prognostic value. These results support a disease-specific use of 6-MWD in the routine assessment of patients with CHRF. Copyright (C) 2007 S. Karger AG, Basel