85 research outputs found

    Herba Epimedii: Anti-oxidative properties and its medical implications

    Get PDF
    Herba Epimedii is a Chinese herbal medicine with proven efficacy in treating cardiovascular diseases and osteoporosis, and in improving sexual and neurological functions. This efficacy is found to be related to the potent anti-oxidative ability of Herba Epimedii and its flavonoid components, with icarrin as the main effective constituent, along with polysaccharides and vitamin C. These ingredients have been proven to be effective against oxidative-stress related pathologies (cardiovascular diseases, Alzheimer's disease and inflammation) in animal rodent models and in vitro studies. Their antioxidative properties are found to be related to an inductive effect on endogenous freeradical scavenging enzymes such as catalase and glutathione peroxidase and the inherent electron-donating ability of flavonoids. © 2010 licensee MDPI, Basel, Switzerland.published_or_final_versio

    Herpes zoster related hospitalization after inactivated (CoronaVac) and mRNA (BNT162b2) SARS-CoV-2 vaccination: A self-controlled case series and nested case-control study

    Get PDF
    BACKGROUND: Stimulation of immunity by vaccination may elicit adverse events. There is currently inconclusive evidence on the relationship between herpes zoster related hospitalization and COVID-19 vaccination. This study aimed to evaluate the effect of inactivated virus (CoronaVac, Sinovac) and mRNA (BNT162b2, BioNTech/Fosun Pharma) COVID-19 vaccine on the risk of herpes zoster related hospitalization. METHODS: Self-controlled case series (SCCS) analysis was conducted using the data from the electronic health records in Hospital Authority and COVID-19 vaccination records in the Department of Health in Hong Kong. We conducted the SCCS analysis including patients with a first primary diagnosis of herpes zoster in the hospital inpatient setting between February 23 and July 31, 2021. A confirmatory analysis by nested case-control method was also conducted. Each herpes zoster case was randomly matched with ten controls according to sex, age, Charlson comorbidity index, and date of hospital admission. Conditional Poisson regression and logistic regression models were used to assess the potential excess rates of herpes zoster after vaccination. FINDINGS: From February 23 to July 31, 2021, a total of 16 and 27 patients were identified with a first primary hospital diagnosis of herpes zoster within 28 days after CoronaVac and BNT162b2 vaccinations. The incidence of herpes zoster was 7.9 (95% Confidence interval [CI]: 5.2–11.5) for CoronaVac and 7.1 (95% CI: 4.1–11.5) for BNT162b2 per 1,000,000 doses administered. In SCCS analysis, CoronaVac vaccination was associated with significantly higher risk of herpes zoster within 14 days after first dose (adjusted incidence rate ratio [aIRR]=2.67, 95% CI: 1.08–6.59) but not in other periods afterwards compared to the baseline period. Regarding BNT162b2 vaccination, a significantly increased risk of herpes zoster was observed after first dose up to 14 days after second dose (0-13 days after first dose: aIRR=5.23, 95% CI: 1.61–17.03; 14–27 days after first dose: aIRR=5.82, 95% CI: 1.62–20.91; 0-13 days after second dose: aIRR=5.14, 95% CI: 1.29–20.47). Using these relative rates, we estimated that there has been an excess of approximately 5 and 7 cases of hospitalization as a result of herpes zoster after every 1,000,000 doses of CoronaVac and BNT162b2 vaccination, respectively. The findings in the nested case control analysis showed similar results. INTERPRETATION: We identified an increased risk of herpes zoster related hospitalization after CoronaVac and BNT162b2 vaccinations. However, the absolute risks of such adverse event after CoronaVac and BNT162b2 vaccinations were very low. In locations where COVID-19 is prevalent, the protective effects on COVID-19 from vaccinations will greatly outweigh the potential side effects of vaccination. FUNDING: The project was funded by Research Grant from the Food and Health Bureau, The Government of the Hong Kong Special Administrative Region (Ref. No.COVID19F01). FTTL (Francisco Tsz Tsun Lai) and ICKW (Ian Chi Kei Wong)’s posts were partly funded by D(2)4H; hence this work was partly supported by AIR@InnoHK administered by Innovation and Technology Commission

    Association between the risk of seizure and COVID-19 vaccinations: A self-controlled case-series study

    Get PDF
    OBJECTIVE: The risk of seizure following BNT162b2 and CoronaVac vaccinations has been sparsely investigated. This study aimed to evaluate this association. METHOD: Patients who had their first seizure-related hospitalization between February 23, 2021 and January 31, 2022 were identified in Hong Kong. All seizure episodes happening on the day of vaccination (day 0) were excluded since clinicians validated that most of the cases on day 0 were syncopal episodes. Within-individual comparison using a modified self-controlled case series analysis was applied to estimate the incidence rate ratio (IRR) with 95% confidence intervals (CI) of seizure using conditional Poisson regression. RESULTS: We identified 1656 individuals who had their first seizure-related hospitalization (BNT162b2: 426; CoronaVac: 263; unvaccinated: 967) within the observation period. The incidence of seizure was 1.04 (95% CI: 0.80-1.33) and 1.11 (95% CI: 0.80-1.50) per 100,000 doses of BNT162b2 and CoronaVac administered respectively. 16 and 17 individuals received second dose after having first seizure within 28 days after first dose of BNT162b2 and CoronaVac vaccinations, respectively. None had recurrent seizures after the second dose. There was no increased risk during day 1-6 after the first (BNT162b2: IRR=1.39, 95% CI=0.75-2.58; CoronaVac: IRR=1.19, 95% CI=0.50-2.83) and second doses (BNT162b2: IRR=1.36, 95% CI 0.72-2.57; CoronaVac: IRR=0.71, 95% CI=0.22-2.30) of vaccinations. During 7-13, 14-20- and 21-27-days post-vaccination, no association was observed for both vaccines. SIGNIFICANCE: The findings demonstrated no increased risk of seizure following BNT162b2 and CoronaVac vaccinations. Future studies will be warranted to evaluate the risk of seizure following COVID-19 vaccinations in different populations with subsequent doses to ensure the generalizability

    A Brief Mindfulness-Based Family Psychoeducation Intervention for Chinese Young Adults With First Episode Psychosis: A Study Protocol

    Get PDF
    Family psychoeducation (FPE) has been recommended as a major component in the treatment of psychosis. Many previous studies have implemented an intensive program design that often only emphasized improvements in patients’ illness outcomes but the benefits for caregivers were limited. There have been calls for a time-limited but cost-effective FPE program to mitigate the looming reality of the suffering of people with psychosis and their families. A Brief Mindfulness-Based Family Psychoeducation for psychosis program is developed to reduce caregivers’ burden and promote young adult’s recovery. A randomized controlled trial will be conducted to compare this intervention with an ordinary FPE intervention. Both arms will involve six sessions, with a total contact time of 12 h. 300 caregivers of young adults who have experienced first episode psychosis within last 3 years will be recruited. Program effectiveness will be assessed by comparing outcomes measuring the caregivers’ burden, mental health symptoms, positive well-being, and the young adult’s mental health symptoms during the study and at 9-month post-randomization. The role of expressed emotions, interpersonal mindfulness, and non-attachment in mediating these outcomes will be explored. An additional qualitative approach Photovoice is selected to explore the complex family experiences and the benefits of mindfulness from the caregivers’ personal perspectives.Trial Registration: The trial is registered with the United States Clinical Trials Registry (ClinicalTrials.gov): NCT03688009

    Graphene Schottky diodes: an experimental review of the rectifying graphene/semiconductor heterojunction

    Full text link
    In the past decade graphene has been one of the most studied material for several unique and excellent properties. Due to its two dimensional nature, physical and chemical properties and ease of manipulation, graphene offers the possibility of integration with the exiting semiconductor technology for next-generation electronic and sensing devices. In this context, the understanding of the graphene/semiconductor interface is of great importance since it can constitute a versatile standalone device as well as the building-block of more advanced electronic systems. Since graphene was brought to the attention of the scientific community in 2004, the device research has been focused on the more complex graphene transistors, while the graphene/semiconductor junction, despite its importance, has started to be the subject of systematic investigation only recently. As a result, a thorough understanding of the physics and the potentialities of this device is still missing. The studies of the past few years have demonstrated that graphene can form junctions with 3D or 2D semiconducting materials which have rectifying characteristics and behave as excellent Schottky diodes. The main novelty of these devices is the tunable Schottky barrier height, a feature which makes the graphene/semiconductor junction a great platform for the study of interface transport mechanisms as well as for applications in photo-detection, high-speed communications, solar cells, chemical and biological sensing, etc. In this paper, we review the state-of-the art of the research on graphene/semiconductor junctions, the attempts towards a modeling and the most promising applications.Comment: 85 pages. Review articl

    Robust estimation of bacterial cell count from optical density

    Get PDF
    Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals <1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data

    Impact of COVID-19 on cardiovascular testing in the United States versus the rest of the world

    Get PDF
    Objectives: This study sought to quantify and compare the decline in volumes of cardiovascular procedures between the United States and non-US institutions during the early phase of the coronavirus disease-2019 (COVID-19) pandemic. Background: The COVID-19 pandemic has disrupted the care of many non-COVID-19 illnesses. Reductions in diagnostic cardiovascular testing around the world have led to concerns over the implications of reduced testing for cardiovascular disease (CVD) morbidity and mortality. Methods: Data were submitted to the INCAPS-COVID (International Atomic Energy Agency Non-Invasive Cardiology Protocols Study of COVID-19), a multinational registry comprising 909 institutions in 108 countries (including 155 facilities in 40 U.S. states), assessing the impact of the COVID-19 pandemic on volumes of diagnostic cardiovascular procedures. Data were obtained for April 2020 and compared with volumes of baseline procedures from March 2019. We compared laboratory characteristics, practices, and procedure volumes between U.S. and non-U.S. facilities and between U.S. geographic regions and identified factors associated with volume reduction in the United States. Results: Reductions in the volumes of procedures in the United States were similar to those in non-U.S. facilities (68% vs. 63%, respectively; p = 0.237), although U.S. facilities reported greater reductions in invasive coronary angiography (69% vs. 53%, respectively; p < 0.001). Significantly more U.S. facilities reported increased use of telehealth and patient screening measures than non-U.S. facilities, such as temperature checks, symptom screenings, and COVID-19 testing. Reductions in volumes of procedures differed between U.S. regions, with larger declines observed in the Northeast (76%) and Midwest (74%) than in the South (62%) and West (44%). Prevalence of COVID-19, staff redeployments, outpatient centers, and urban centers were associated with greater reductions in volume in U.S. facilities in a multivariable analysis. Conclusions: We observed marked reductions in U.S. cardiovascular testing in the early phase of the pandemic and significant variability between U.S. regions. The association between reductions of volumes and COVID-19 prevalence in the United States highlighted the need for proactive efforts to maintain access to cardiovascular testing in areas most affected by outbreaks of COVID-19 infection
    corecore