2,513 research outputs found
Coherent beam combining of high power quasi continuous wave tapered amplifiers
International audienceWe demonstrate coherent beam combining of four high brightness tapered amplifiers in pulsed, quasi continuous wave (QCW) operation, seeded by a 976 nm laser diode. The maximum power of 22.7 W was achieved with > 64 % combining efficiency in a close to diffraction limited beam. We discuss turn-on dynamics of tapered amplifiers operated in pulsed mode in detail
Argentina. Sello Alimentos Argentinos
Resumen Alimentos Argentinos es un sello de calidad que distingue los alimentos argentinos y sus atributos diferenciadores –proceso, producto y envase-. Es gratuito, temporal, voluntario y puede ser solicitado por productores y/o elaboradores de alimentos, que cumplan con el Protocolo correspondiente. El cumplimiento a dichos protocolos es auditado por terceros independientes, habilitados para tal fin.Fil: Pighin, Darío Gabriel. Instituto Nacional de Tecnología Agropecuaria (INTA). CIA. Instituto Tecnología de Alimentos; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET); Argentina. Universidad de Morón; Argentina.Fil: Tam, C. Ministerio de Producción y Trabajo. Secretaría de Gobierno de Agroindustria; Argentina.Fil: Pazos, Adriana Alejandra. Instituto Nacional de Tecnología Agropecuaria (INTA). CIA. Instituto Tecnología de Alimentos; Argentina. Universidad de Morón; Argentina.Fil: Barcus, M. C. Ministerio de Producción y Trabajo. Secretaría de Gobierno de Agroindustria; Argentina.Fil: Moron, J. M. Ministerio de Producción y Trabajo. Secretaría de Gobierno de Agroindustria; Argentina.Fil: Moron, P. H. Ministerio de Producción y Trabajo. Secretaría de Gobierno de Agroindustria; Argentina.Fil: Nimo, M. Ministerio de Producción y Trabajo. Secretaría de Gobierno de Agroindustria; Argentina.Fil: Grigioni, Gabriela Maria. Instituto Nacional de Tecnología Agropecuaria (INTA). CIA. Instituto Tecnología de Alimentos; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET); Argentina. Universidad de Morón; Argentina
Measurement of shower development and its Moli\`ere radius with a four-plane LumiCal test set-up
A prototype of a luminometer, designed for a future e+e- collider detector,
and consisting at present of a four-plane module, was tested in the CERN PS
accelerator T9 beam. The objective of this beam test was to demonstrate a
multi-plane tungsten/silicon operation, to study the development of the
electromagnetic shower and to compare it with MC simulations. The Moli\`ere
radius has been determined to be 24.0 +/- 0.6 (stat.) +/- 1.5 (syst.) mm using
a parametrization of the shower shape. Very good agreement was found between
data and a detailed Geant4 simulation.Comment: Paper published in Eur. Phys. J., includes 25 figures and 3 Table
ECFA Detector R&D Panel, Review Report
Two special calorimeters are foreseen for the instrumentation of the very
forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to
measure the rate of low angle Bhabha scattering events with a precision better
than 10 at the ILC and 10 at CLIC, and a low polar-angle
calorimeter (BeamCal). The latter will be hit by a large amount of
beamstrahlung remnants. The intensity and the spatial shape of these
depositions will provide a fast luminosity estimate, as well as determination
of beam parameters. The sensors of this calorimeter must be radiation-hard.
Both devices will improve the e.m. hermeticity of the detector in the search
for new particles. Finely segmented and very compact electromagnetic
calorimeters will match these requirements. Due to the high occupancy, fast
front-end electronics will be needed. Monte Carlo studies were performed to
investigate the impact of beam-beam interactions and physics background
processes on the luminosity measurement, and of beamstrahlung on the
performance of BeamCal, as well as to optimise the design of both calorimeters.
Dedicated sensors, front-end and ADC ASICs have been designed for the ILC and
prototypes are available. Prototypes of sensor planes fully assembled with
readout electronics have been studied in electron beams.Comment: 61 pages, 51 figure
Performance of fully instrumented detector planes of the forward calorimeter of a Linear Collider detector
Detector-plane prototypes of the very forward calorimetry of a future
detector at an e+e- collider have been built and their performance was measured
in an electron beam. The detector plane comprises silicon or GaAs pad sensors,
dedicated front-end and ADC ASICs, and an FPGA for data concentration.
Measurements of the signal-to-noise ratio and the response as a function of the
position of the sensor are presented. A deconvolution method is successfully
applied, and a comparison of the measured shower shape as a function of the
absorber depth with a Monte-Carlo simulation is given.Comment: 25 pages, 32 figures, revised version following comments from
referee
Observation of two new baryon resonances
Two structures are observed close to the kinematic threshold in the mass spectrum in a sample of proton-proton collision data, corresponding
to an integrated luminosity of 3.0 fb recorded by the LHCb experiment.
In the quark model, two baryonic resonances with quark content are
expected in this mass region: the spin-parity and
states, denoted and .
Interpreting the structures as these resonances, we measure the mass
differences and the width of the heavier state to be
MeV,
MeV,
MeV, where the first and second
uncertainties are statistical and systematic, respectively. The width of the
lighter state is consistent with zero, and we place an upper limit of
MeV at 95% confidence level. Relative
production rates of these states are also reported.Comment: 17 pages, 2 figure
Measurement of the lifetime
Using a data set corresponding to an integrated luminosity of ,
collected by the LHCb experiment in collisions at centre-of-mass energies
of 7 and 8 TeV, the effective lifetime in the
decay mode, , is measured to be ps. Assuming
conservation, corresponds to the lifetime of the light
mass eigenstate. This is the first measurement of the effective
lifetime in this decay mode.Comment: All figures and tables, along with any supplementary material and
additional information, are available at
https://lhcbproject.web.cern.ch/lhcbproject/Publications/LHCbProjectPublic/LHCb-PAPER-2016-017.htm
Measurement of the mass and lifetime of the baryon
A proton-proton collision data sample, corresponding to an integrated
luminosity of 3 fb collected by LHCb at and 8 TeV, is used
to reconstruct , decays. Using the , decay mode for calibration, the lifetime ratio and absolute
lifetime of the baryon are measured to be \begin{align*}
\frac{\tau_{\Omega_b^-}}{\tau_{\Xi_b^-}} &= 1.11\pm0.16\pm0.03, \\
\tau_{\Omega_b^-} &= 1.78\pm0.26\pm0.05\pm0.06~{\rm ps}, \end{align*} where the
uncertainties are statistical, systematic and from the calibration mode (for
only). A measurement is also made of the mass difference,
, and the corresponding mass, which
yields \begin{align*} m_{\Omega_b^-}-m_{\Xi_b^-} &= 247.4\pm3.2\pm0.5~{\rm
MeV}/c^2, \\ m_{\Omega_b^-} &= 6045.1\pm3.2\pm 0.5\pm0.6~{\rm MeV}/c^2.
\end{align*} These results are consistent with previous measurements.Comment: 11 pages, 5 figures, All figures and tables, along with any
supplementary material and additional information, are available at
https://lhcbproject.web.cern.ch/lhcbproject/Publications/LHCbProjectPublic/LHCb-PAPER-2016-008.htm
Observation of resonances consistent with pentaquark states in decays
Observations of exotic structures in the channel, that we refer to
as pentaquark-charmonium states, in decays are
presented. The data sample corresponds to an integrated luminosity of 3/fb
acquired with the LHCb detector from 7 and 8 TeV pp collisions. An amplitude
analysis is performed on the three-body final-state that reproduces the
two-body mass and angular distributions. To obtain a satisfactory fit of the
structures seen in the mass spectrum, it is necessary to include two
Breit-Wigner amplitudes that each describe a resonant state. The significance
of each of these resonances is more than 9 standard deviations. One has a mass
of MeV and a width of MeV, while the second
is narrower, with a mass of MeV and a width of MeV. The preferred assignments are of opposite parity, with one
state having spin 3/2 and the other 5/2.Comment: 48 pages, 18 figures including the supplementary material, v2 after
referee's comments, now 19 figure
- …