1,175 research outputs found

    Is quality of care improving in the UK?

    Get PDF
    Yes, but we do not know wh

    Explant analysis and implant registries are both needed to further improve patient safety

    Full text link
    In the early days of total joint replacement, implant fracture, material problems and wear presented major problems for the long-term success of the operation. Today, failures directly related to the implant comprise only 2–3% of the reasons for revision surgeries, which is a result of the material and design improvements in combination with the standardization of pre-clinical testing methods and the post-market surveillance required by the legal regulation. Arthroplasty registers are very effective tools to document the long-term clinical performance of implants and implantation techniques such as fixation methods in combination with patient characteristics. Revisions due to implant failure are initially not reflected by the registries due to their small number. Explant analysis including patient, clinical and imaging documentation is crucial to identify failure mechanisms early enough to prevent massive failures detectable in the registries. In the past, early reaction was not always successful, since explant analysis studies have either been performed late or the results did not trigger preventive measures until clinical failures affected a substantial number of patients. The identification of implant-related problems is only possible if all failures are reported and related to the number of implantations. A system that analyses all explants from revisions attributed to implant failure is mandatory to reduce failures, allowing improvement of risk assessment in the regulatory proces

    Tests of Transfer Reaction Determinations of Astrophysical S-Factors

    Get PDF
    The 16O(3He,d)17F{}^{16}O ({}^{3}He,d) {}^{17}F reaction has been used to determine asymptotic normalization coefficients for transitions to the ground and first excited states of 17F{}^{17}F. The coefficients provide the normalization for the tails of the overlap functions for 17F16O+p{}^{17}F \to{}^{16}O + p and allow us to calculate the S-factors for 16O(p,γ)17F{}^{16}O (p,\gamma){}^{17}F at astrophysical energies. The calculated S-factors are compared to measurements and found to be in very good agreement. This provides the first test of this indirect method to determine astrophysical direct capture rates using transfer reactions. In addition, our results yield S(0) for capture to the ground and first excited states in 17F^{17}F, without the uncertainty associated with extrapolation from higher energies.Comment: 6 pages, 2 figure

    The taper corrosion pattern observed for one bi-modular stem design is related to geometry-determined taper mechanics

    Get PDF
    Bi-modular primary hip stems exhibit high revision rates owing to corrosion at the stem-neck taper, and are associated with local adverse tissue reactions. The aim of this study was to relate the wear patterns observed for one bi-modular design to its design-specific stem-neck taper geometry. Wear patterns and initial geometry of the taper junctions were determined for 27 retrieved bi-modular primary hip arthroplasty stems (Rejuvenate, Stryker Orthopaedics) using a tactile coordinate-measuring device. Regions of high-gradient wear patterns were additionally analyzed via optical and electron microscopy. The determined geometry of the taper junction revealed design-related engagement at its opening (angle mismatch), concentrated at the medial and lateral apexes (axes mismatch). A patch of retained topography on the proximal medial neck-piece taper apex was observed, surrounded by regions of high wear. On the patch, a deposit from the opposing female stem taper—containing Ti, Mo, Zr, and O—was observed. High stress concentrations were focused at the taper apexes owing to the specific geometry. A medial canting of the components may have augmented the inhomogeneous stress distributions in vivo. In the regions with high normal loads interfacial slip and consequently fretting was inhibited, which explains the observed pattern of wear

    Authigenic minerals reflect microbial control on pore waters in a ferruginous analogue

    Get PDF
    Ferruginous conditions prevailed in the oceans through much of Earth's history. However, minerals recording these conditions remain difficult to interpret in terms of biogeochemical processes prior to lithification. In Lake Towuti, Indonesia, ferruginous sediments are deposited under anoxic sulfate-poor conditions similar to the Proterozoic oceans, allowing the study of mineralogical (trans)formations during microbial diagenesis. Comprehensive pore water geochemistry, high resolution geochemical core profiles, and electron microscopy of authigenic minerals revealed in situ formation of magnetite, millerite, and abundant siderite and vivianite along a 100 m long sequence. Framboidal magnetites represent primary pelagic precipitates, whereas millerite, a sulfide mineral often overlooked under sulfate-poor conditions, shows acicular aggregates entangled with siderite and vivianite resulting from saturated pore waters and continuous growth during burial. These phases act as biosignatures of microbial iron and sulfate reduction, fermentation and methanogenesis, processes clearly traceable in pore water profiles. Variability in metal and organic substrates attests to environment driven processes, differentially sustaining microbial processes along the stratigraphy. Geochemical profiles resulting from microbial activity over 200 kyr after deposition provide constraints on the depth and age of mineral formation within ferruginous records

    Breakup of 17^{17}F on 208^{208}Pb near the Coulomb barrier

    Full text link
    Angular distributions of oxygen produced in the breakup of 17^{17}F incident on a 208^{208}Pb target have been measured around the grazing angle at beam energies of 98 and 120 MeV. The data are dominated by the proton stripping mechanism and are well reproduced by dynamical calculations. The measured breakup cross section is approximately a factor of 3 less than that of fusion at 98 MeV. The influence of breakup on fusion is discussed.Comment: 7 pages, 8 figure

    Osteoidosis leads to altered differentiation and function of osteoclasts

    Full text link
    In patients with osteomalacia, a defect in bone mineralization leads to changed characteristics of the bone surface. Considering that the properties of the surrounding matrix influence function and differentiation of cells, we aimed to investigate the effect of osteoidosis on differentiation and function of osteoclasts. Based on osteomalacic bone biopsies, a model for osteoidosis in vitro (OIV) was established. Peripheral blood mononuclear cells were differentiated to osteoclasts on mineralized surfaces (MS) as internal control and on OIV. We observed a significantly reduced number of osteoclasts and surface resorption on OIV. Atomic force microscopy revealed a significant effect of the altered degree of mineralization on surface mechanics and an unmasking of collagen fibres on the surface. Indeed, coating of MS with RGD peptides mimicked the resorption phenotype observed in OIV, suggesting that the altered differentiation of osteoclasts on OIV might be associated with an interaction of the cells with amino acid sequences of unmasked extracellular matrix proteins containing RGD sequences. Transcriptome analysis uncovered a strong significant up-regulation of transmembrane glycoprotein TROP2 in osteoclastic cultures on OIV. TROP2 expression on OIV was also confirmed on the protein level and found on the bone surface of patients with osteomalacia. Taken together, our results show a direct influence of the mineralization state of the extracellular matrix surface on differentiation and function of osteoclasts on this surface which may be important for the pathophysiology of osteomalacia and other bone disorders with changed ratio of osteoid to bone

    Evidence for t\bar{t}\gamma Production and Measurement of \sigma_t\bar{t}\gamma / \sigma_t\bar{t}

    Get PDF
    Using data corresponding to 6.0/fb of ppbar collisions at sqrt(s) = 1.96 TeV collected by the CDF II detector, we present a cross section measurement of top-quark pair production with an additional radiated photon. The events are selected by looking for a lepton, a photon, significant transverse momentum imbalance, large total transverse energy, and three or more jets, with at least one identified as containing a b quark. The ttbar+photon sample requires the photon to have 10 GeV or more of transverse energy, and to be in the central region. Using an event selection optimized for the ttbar+photon candidate sample we measure the production cross section of, and the ratio of cross sections of the two samples. Control samples in the dilepton+photon and lepton+photon+\met, channels are constructed to aid in decay product identification and background measurements. We observe 30 ttbar+photon candidate events compared to the standard model expectation of 26.9 +/- 3.4 events. We measure the ttbar+photon cross section to be 0.18+0.08 pb, and the ratio of the cross section of ttbar+photon to ttbar to be 0.024 +/- 0.009. Assuming no ttbar+photon production, we observe a probability of 0.0015 of the background events alone producing 30 events or more, corresponding to 3.0 standard deviations.Comment: 9 pages, 3 figure

    Formulae for the Analysis of the Flavor-Tagged Decay B^0_s --> Jpsi phi

    Get PDF
    Differential rates in the decay B^0_s --> Jpsi phi, with phi --> K^+K^- and Jpsi --> mu^+ mu^- are sensitive to the CP-violation phase beta_s, predicted to be very small in the standard model. The analysis of B^0_s --> Jpsi phi decays is also suitable for measuring the B^0_s lifetime, the decay width difference DeltaGamma_s between the B^0_s mass eigenstates, and the B^0_s oscillation frequency Delta m even if appreciable CP violation does not occur. In this paper we present normalized probability densities useful in maximum likelihood fits, extended to allow for S-wave contributions on one hand and for the effects of direct CP violation on the other. Our treatment of the S-wave contributions includes the strong variation of the S-wave/P-wave amplitude ratio with m(K^+K^-) across the phi resonance, which was not considered in previous work. We include a scheme for re-normalizing the probability densities after detector sculpting of the angular distributions of the final state particles, and conclude with an examination of the symmetries of the rate formulae, with and without an S-wave contribution. All results are obtained with the use of a new compact formalism describing the differential decay rate of B^0_s mesons into Jpsi phi final states.Comment: 19 pages, no figures. Revised for JHE
    corecore