2,548 research outputs found

    Fast Feedback Cycles in Empirical Software Engineering Research

    Get PDF
    Background/Context: Gathering empirical knowledge is a time consuming task and the results from empirical studies often are soon outdated by new technological solutions. As a result, the impact of empirical results on software engineering practice is often not guaranteed. Objective/Aim: In this paper, we summarize the ongoing discussion on ”Empirical Software Engineering 2.0” as a way to improve the impact of empirical results on indus- trial practices. We propose a way to combine data mining and analysis with domain knowledge to enable fast feedback cycles between researchers and practitioners. Method: We identify the key concepts on gathering fast feedback in empirical software engineering by following an experience-based line of reasoning by argument. Based on the identified key concepts, we design and execute a small proof of concept with a company, to demonstrate potential benefits of the approach. Results: In our example we observed that a simple double feedback mechanism notably increased the precision of the data analysis and improved the quality of the knowledge gathered. Conclusion: Our results serve as a basis to foster discus- sion and collaboration within the research community for a development of the idea

    Awareness of secure coding guidelines in the industry - A first data analysis

    Get PDF
    Software needs to be secure, in particular when deployed to critical infrastructures. Secure coding guidelines capture practices in industrial software engineering to ensure the security of code. This study aims at assessing the level of awareness of secure coding in industrial software engineering, the skills of software developers to spot weaknesses in software code, and avoid them, as well as the organizational support to adhere to coding guidelines. The approach draws not only on well-established theories of policy compliance, neutralization theory, and security-related stress but also on the authors’ many years of experience in industrial software engineering and on lessons identified from training secure coding in the industry. The paper presents the design of the questionnaire for the online survey and the first analysis of data from the pilot study.info:eu-repo/semantics/acceptedVersio

    Tennis play intensity distribution and relation with aerobic fitness in competitive players

    Get PDF
    15 p.Los objetivos de este estudio fueron (1) describir la intensidad relativa del juego de tenis simulado en función del tiempo acumulado en tres zonas de intensidad metabólica y (2) determinar las relaciones entre esta distribución de intensidad de juego y la aptitud aeróbica de un grupo de jugadores competitivos. 20 jugadores masculinos de nivel avanzado a élite (ITN) realizaron una prueba de tenis de resistencia específica en el campo incremental hasta el agotamiento para determinar el consumo máximo de oxígeno (VO2max) y los umbrales de ventilación primero y segundo (VT1, VT2). Los parámetros de ventilación y de intercambio de gases se monitorizaron utilizando un analizador de gas portátil telemétrico (K4 b2, Cosmed, Roma, Italia). Dos semanas después, los participantes jugaron un juego de tenis simulado contra un oponente de nivel similar. Las zonas de intensidad (1: baja, 2: moderada y 3: alta) fueron delimitadas por los valores individuales de VO2 correspondientes a VT1 y VT2, y se expresaron como porcentaje del VO2 máximo y la frecuencia cardíaca. Cuando se expresó en relación con el VO 2 máx. El porcentaje de tiempo de juego en la zona 1 (77 ± 25%) fue significativamente mayor (p <0,001) que en la zona 2 (20 ± 21%) y la zona 3 (3 ± 5%). Se encontraron correlaciones positivas de moderadas a altas entre VT1, VT2 y VO2max, y el porcentaje del tiempo de juego transcurrido en la zona 1 (r = 0,68-0,75), así como las correlaciones inversas de bajas a altas entre las variables metabólicas y el porcentaje de tiempo empleado en las zonas 2 y 3 (r = -0.49–0.75). Los jugadores con mejor aptitud aeróbica juegan a intensidades relativamente más bajas. Concluimos que los jugadores pasaron más del 75% del tiempo en su zona de baja intensidad, con menos del 25% del tiempo dedicado a intensidades moderadas a altas. La aptitud aeróbica parece determinar la intensidad metabólica que los jugadores pueden mantener durante todo el juegoS

    POLD3 Is Haploinsufficient for DNA Replication in Mice

    Get PDF
    The Pold3 gene encodes a subunit of the Polδ DNA polymerase complex. Pold3 orthologs are not essential in Saccharomyces cerevisiae or chicken DT40 cells, but the Schizosaccharomyces pombe ortholog is essential. POLD3 also has a specialized role in the repair of broken replication forks, suggesting that POLD3 activity could be particularly relevant for cancer cells enduring high levels of DNA replication stress. We report here that POLD3 is essential for mouse development and is also required for viability in adult animals. Strikingly, even Pold3(+/-) mice were born at sub-Mendelian ratios, and, of those born, some presented hydrocephaly and had a reduced lifespan. In cells, POLD3 deficiency led to replication stress and cell death, which were aggravated by the expression of activated oncogenes. Finally, we show that Pold3 deletion destabilizes all members of the Polδ complex, explaining its major role in DNA replication and the severe impact of its deficiency.Research was funded by Fundacion Botin, Banco Santander, through its Santander Universities Global Division, and by grants from the Spanish Ministry of Economy and Competitiveness (MINECO) (SAF2014-59498-R; SAF2014-57791-REDC), Fundacio La Marato de TV3, the Howard Hughes Medical Institute, and the European Research Council (ERC-617840) to O.F.-C.; by a Marie Curie International Outgoing Fellowshp (IOF) from the FP7 Marie Curie Actions and a grant from MINECO (BFU2014-55168-JIN) that was co-funded by European Regional Development Funds (FEDER) to E.L.; by a grant from MINECO (BFU2013-49153) to J.M.; and by the European Commission (ERC grant ONIDDAC) to T.D.H.S

    Ibuprofen-loaded calcium phosphate granules : combination of innovative characterization methods to relate mechanical strength to drug location

    Get PDF
    This paper studies the impact of the location of a drug substance on the physicochemical and mechanical properties of two types of calcium phosphate granules loaded with seven different contents of ibuprofen, ranging from 1.75% to 46%. These implantable agglomerates were produced by either low or high shear granulation. Unloaded Mi-Pro pellets presented higher sphericity and mechanical properties, but were slightly less porous than Kenwood granules (57.7% vs 61.2%). Nevertheless, the whole expected quantity of ibuprofen could be integrated into both types of granules. A combination of surface analysis, using near-infrared (NIR) spectroscopy coupling chemical imaging, and pellet porosity, by mercury intrusion measurements, allowed ibuprofen to be located. It was shown that, from 0% to 22% drug content, ibuprofen deposited simultaneously on the granule surface, as evidenced by the increase in surface NIR signal, and inside the pores, as highlighted by the decrease in pore volume. From 22%, porosity was almost filled, and additional drug substance coated the granule surfaces, leading to a large increase in the surface NIR signal. This coating was more regular for Mi-Pro pellets owing to their higher sphericity and greater surface deposition of drug substance. Unit crush tests using a microindenter revealed that ibuprofen loading enhanced the mechanical strength of granules, especially above 22% drug content, which was favorable to further application of the granules as a bone defect filler

    Predictors Of Positivity Of [F-18]F-Choline PET-CT In Prostate Cancer Recurrence. Preliminary Results

    Get PDF
    EP-173 Aim/Introduction: To analyze the validity of [18F]F-Choline PET-CT results in prostate cancer recurrence in our daily practice, based on theoretical cut-off points of prostatespecific antigen (PSA), its kinetic, and PSA doubling time (PSADT), to identify predictors of positivity and modify the indication criteria. Materials and Methods: Prior to the validity analysis, a descriptive, prospective analysis of consecutive patients with prostate cancer treated with curative intent by radical prostatectomy (RP) or radiotherapy (RT), who underwent PET-CT scan with recurrence criteria: PSA =1 or PSA 0.4-1 with PSADT Nadir + 2 after RT, was performed. Results: From April to December 2019, 69 patients were included, 40 were treated with RP (58%) and 29 with RT (42%). In 45 patients (65%) PET-CT was able to identify recurrence of the disease (positive PET) and in 24 it was not (negative PET). Of patients treated with RP, 82, 5% (33/40) had PSA>1, and of those, 61% were positive PET. 17, 5% (7/40) had PSA6months (28/69), in 71% if PSADT6 months, in 61% and 92% if PSADT<6 months and in 77% and 100% if PSADT<3 months. Conclusion: Preliminarily and awaiting validation, it seems that PSA>1 after RP or Nadir +2 after RT is an indicator of PET-CT. There seems to be a tendency that shows that PSA<1 after RP is an indicator of PET-CT if PSADT<3 months. PSADT <3 or <6 months could be the best predictor of positivity of PET-CT with [18F]F-Choline in recurrent prostate cancer

    Loop Quantum Gravity and the The Planck Regime of Cosmology

    Full text link
    The very early universe provides the best arena we currently have to test quantum gravity theories. The success of the inflationary paradigm in accounting for the observed inhomogeneities in the cosmic microwave background already illustrates this point to a certain extent because the paradigm is based on quantum field theory on the curved cosmological space-times. However, this analysis excludes the Planck era because the background space-time satisfies Einstein's equations all the way back to the big bang singularity. Using techniques from loop quantum gravity, the paradigm has now been extended to a self-consistent theory from the Planck regime to the onset of inflation, covering some 11 orders of magnitude in curvature. In addition, for a narrow window of initial conditions, there are departures from the standard paradigm, with novel effects, such as a modification of the consistency relation involving the scalar and tensor power spectra and a new source for non-Gaussianities. Thus, the genesis of the large scale structure of the universe can be traced back to quantum gravity fluctuations \emph{in the Planck regime}. This report provides a bird's eye view of these developments for the general relativity community.Comment: 23 pages, 4 figures. Plenary talk at the Conference: Relativity and Gravitation: 100 Years after Einstein in Prague. To appear in the Proceedings to be published by Edition Open Access. Summarizes results that appeared in journal articles [2-13

    Multi-Wavelength Observations of the Blazar 1ES 1011+496 in Spring 2008

    Get PDF
    The BL Lac object 1ES 1011+496 was discovered at Very High Energy gamma-rays by MAGIC in spring 2007. Before that the source was little studied in different wavelengths. Therefore a multi-wavelength (MWL) campaign was organized in spring 2008. Along MAGIC, the MWL campaign included the Metsahovi radio observatory, Bell and KVA optical telescopes and the Swift and AGILE satellites. MAGIC observations span from March to May, 2008 for a total of 27.9 hours, of which 19.4 hours remained after quality cuts. The light curve showed no significant variability. The differential VHE spectrum could be described with a power-law function. Both results were similar to those obtained during the discovery. Swift XRT observations revealed an X-ray flare, characterized by a harder when brighter trend, as is typical for high synchrotron peak BL Lac objects (HBL). Strong optical variability was found during the campaign, but no conclusion on the connection between the optical and VHE gamma-ray bands could be drawn. The contemporaneous SED shows a synchrotron dominated source, unlike concluded in previous work based on nonsimultaneous data, and is well described by a standard one zone synchrotron self Compton model. We also performed a study on the source classification. While the optical and X-ray data taken during our campaign show typical characteristics of an HBL, we suggest, based on archival data, that 1ES 1011+496 is actually a borderline case between intermediate and high synchrotron peak frequency BL Lac objects.Comment: 13 pages, accepted for publication in MNRA

    Observation of Pulsed Gamma-rays Above 25 GeV from the Crab Pulsar with MAGIC

    Get PDF
    One fundamental question about pulsars concerns the mechanism of their pulsed electromagnetic emission. Measuring the high-end region of a pulsar's spectrum would shed light on this question. By developing a new electronic trigger, we lowered the threshold of the Major Atmospheric gamma-ray Imaging Cherenkov (MAGIC) telescope to 25 GeV. In this configuration, we detected pulsed gamma-rays from the Crab pulsar that were greater than 25 GeV, revealing a relatively high cutoff energy in the phase-averaged spectrum. This indicates that the emission occurs far out in the magnetosphere, hence excluding the polar-cap scenario as a possible explanation of our measurement. The high cutoff energy also challenges the slot-gap scenario.Comment: Slight modification of the analysis: Fitting a more general function to the combined data set of COMPTEL, EGRET and MAGIC. Final result and conclusion is unchange

    Rapid tests and urine sampling techniques for the diagnosis of urinary tract infection (UTI) in children under five years: a systematic review

    Get PDF
    Background: Urinary tract infection (UTI) is one of the most common sources of infection in children under five. Prompt diagnosis and treatment is important to reduce the risk of renal scarring. Rapid, cost-effective, methods of UTI diagnosis are required as an alternative to culture. Methods: We conducted a systematic review to determine the diagnostic accuracy of rapid tests for detecting UTI in children under five years of age. Results: The evidence supports the use of dipstick positive for both leukocyte esterase and nitrite (pooled LR+ = 28.2, 95% CI: 17.3, 46.0) or microscopy positive for both pyuria and bacteriuria (pooled LR+ = 37.0, 95% CI: 11.0, 125.9) to rule in UTI. Similarly dipstick negative for both LE and nitrite (Pooled LR- = 0.20, 95% CI: 0.16, 0.26) or microscopy negative for both pyuria and bacteriuria (Pooled LR- = 0.11, 95% CI: 0.05, 0.23) can be used to rule out UTI. A test for glucose showed promise in potty-trained children. However, all studies were over 30 years old. Further evaluation of this test may be useful. Conclusion: Dipstick negative for both LE and nitrite or microscopic analysis negative for both pyuria and bacteriuria of a clean voided urine, bag, or nappy/pad specimen may reasonably be used to rule out UTI. These patients can then reasonably be excluded from further investigation, without the need for confirmatory culture. Similarly, combinations of positive tests could be used to rule in UTI, and trigger further investigation
    corecore