460 research outputs found
A Digital Revival of Oriental Studies
The Digital Orientalist est une revue numĂŠrique Ă la fois multidisciplinaire et internationale qui publie des courts articles sur lâutilisation des mĂŠthodes numĂŠriques et des technologies dâinformation dans les ĂŠtudes orientales. Elle contient des articles sur les divers sujets ĂŠcrits par les chercheurs, ĂŠtudiants et bibliothĂŠcaires de diffĂŠrents pays. Les ĂŠtudes islamiques, les ĂŠtudes japonaises et asiatiques, lâarchĂŠologie, lâinformatique, la cartographie numĂŠrique, les ĂŠtudes africaines et les ĂŠtudes indiennes sont parmi ces sujets. Cet article vise Ă expliquer la raison dâĂŞtre de la revue ainsi que la façon dont la revue utilise le terme ÂŤÂ orientaliste . Il fait valoir lâimportance de lâutilisation des nouvelles technologies dâinformation dans la recherche et lâenseignement des ĂŠtudes orientales.The Digital Orientalist is a multidisciplinary and international online magazine that publishes short articles on using information technologies and digital humanities methods in Oriental Studies disciplines. It consists of the articles on a variety of topics written by scholars, students and librarians from different countries. These topics include but not limited to Islamic Studies, Japanese and East Asian Studies, Archaeology, Information Science, Digital Cartography, African Studies and Indian Studies. This article aims to explain the Digital Orientalistâs raison dâĂŞtre as well as the way it uses the term âOrientalistâ. It highlights the importance of the new technologies and digital humanities in research and teaching of Oriental Studies
Web-based monitoring tools for Resistive Plate Chambers in the CMS experiment at CERN
The Resistive Plate Chambers (RPC) are used in the CMS experiment at the trigger level and also in the standard offline muon reconstruction. In order to guarantee the quality of the data collected and to monitor online the detector performance, a set of tools has been developed in CMS which is heavily used in the RPC system. The Web-based monitoring (WBM) is a set of java servlets that allows users to check the performance of the hardware during data taking, providing distributions and history plots of all the parameters. The functionalities of the RPC WBM monitoring tools are presented along with studies of the detector performance as a function of growing luminosity and environmental conditions that are tracked over time
Radiation background with the CMS RPCs at the LHC
The Resistive Plate Chambers (RPCs) are employed in the CMS Experiment at the LHC as dedicated trigger system both in the barrel and in the endcap. This article presents results of the radiation background measurements performed with the 2011 and 2012 proton-proton collision data collected by CMS. Emphasis is given to the measurements of the background distribution inside the RPCs. The expected background rates during the future running of the LHC are estimated both from extrapolated measurements and from simulation
Increased blood product use among coronary artery bypass patients prescribed preoperative aspirin and clopidogrel
BACKGROUND: The administration of antiplatelet drugs before coronary artery bypass graft surgery (CABG) is associated with an increased risk of major hemorrhage and related surgical reexploration. Little is known about the relative effect of combined clopidogrel and aspirin on blood product use around the time of CABG. We evaluated the associated risk between the combined use of aspirin and clopidogrel and the transfusion of blood products perioperatively. METHODS: We retrospectively studied a cohort of 659 individuals who underwent a first CABG, without concomitant valvular or aortic surgery, at a single large Canadian cardiac surgical centre between January 2000 and April 2002. The four study exposure groups were those prescribed aspirin (n = 105), clopidogrel (n = 11), the combination of both (n = 46), or neither drug (n = 497), within 7 days prior to CABG. The primary study outcome was the excessive transfusion of blood products during CABG and up to the second post-operative day, defined as ⼠2 units of packed red blood cells (PRBC), ⼠2 units of fresh frozen plasma, ⼠5 units of cryoprecipitate or ⼠5 units of platelets. Secondary outcomes included the mean number of transfused units of each type of blood product. RESULTS: A greater mean number of units of PRBC were transfused among those who received clopidogrel alone (2.9) or in combination with aspirin (2.4), compared to those on aspirin alone (1.9) or neither antiplatelet drug (1.4) (P = 0.001). A similar trend was seen for the respective mean number of transfused units of platelets (3.6, 3.7, 1.3 and 1.0; P < 0.001) and fresh frozen plasma (2.5, 3.1, 2.3, 1.6; P = 0.01). Compared to non-users, the associated risk of excessive blood product transfusion was highest among recipients of aspirin and clopidogrel together (adjusted OR 2.2, 95% CI 1.1â4.3). No significant association was seen among lone users of aspirin (adjusted OR 1.0, 95% CI 0.6â1.6) or clopidogrel (adjusted OR 0.7, 95% CI 0.2â2.5), compared to non-users. CONCLUSIONS: While combined use of aspirin and clopidogrel shortly before CABG surgery may increase the associated risk of excess transfusion of blood products perioperatively, several study limitations prevent any confident conclusions from being drawn. Beyond challenging these findings, future research might focus on the value of both intraoperative monitoring of platelet function, and the effectiveness of antifibrinolytic agents, at reducing the risk of postoperative bleeding
Extracorporeal life support in pediatric cardiac dysfunction
<p>Abstract</p> <p>Background</p> <p>Low cardiac output (LCO) after corrective surgery remains a serious complication in pediatric congenital heart diseases (CHD). In the case of refractory LCO, extra corporeal life support (ECLS) extra corporeal membrane oxygenation (ECMO) or ventricle assist devices (VAD) is the final therapeutic option. In the present study we have reviewed the outcomes of pediatric patients after corrective surgery necessitating ECLS and compared outcomes with pediatric patients necessitating ECLS because of dilatated cardiomyopathy (DCM).</p> <p>Methods</p> <p>A retrospective single-centre cohort study was evaluated in pediatric patients, between 1991 and 2008, that required ECLS. A total of 48 patients received ECLS, of which 23 were male and 25 female. The indications for ECLS included CHD in 32 patients and DCM in 16 patients.</p> <p>Results</p> <p>The mean age was 1.2 Âą 3.9 years for CHD patients and 10.4 Âą 5.8 years for DCM patients. Twenty-six patients received ECMO and 22 patients received VAD. A total of 15 patients out of 48 survived, 8 were discharged after myocardial recovery and 7 were discharged after successful heart transplantation. The overall mortality in patients with extracorporeal life support was 68%.</p> <p>Conclusion</p> <p>Although the use of ECLS shows a significantly high mortality rate it remains the ultimate chance for children. For better results, ECLS should be initiated in the operating room or shortly thereafter. Bridge to heart transplantation should be considered if there is no improvement in cardiac function to avoid irreversible multiorgan failure (MFO).</p
Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV
The performance of muon reconstruction, identification, and triggering in CMS
has been studied using 40 inverse picobarns of data collected in pp collisions
at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection
criteria covering a wide range of physics analysis needs have been examined.
For all considered selections, the efficiency to reconstruct and identify a
muon with a transverse momentum pT larger than a few GeV is above 95% over the
whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4,
while the probability to misidentify a hadron as a muon is well below 1%. The
efficiency to trigger on single muons with pT above a few GeV is higher than
90% over the full eta range, and typically substantially better. The overall
momentum scale is measured to a precision of 0.2% with muons from Z decays. The
transverse momentum resolution varies from 1% to 6% depending on pseudorapidity
for muons with pT below 100 GeV and, using cosmic rays, it is shown to be
better than 10% in the central region up to pT = 1 TeV. Observed distributions
of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV
The performance of muon reconstruction, identification, and triggering in CMS
has been studied using 40 inverse picobarns of data collected in pp collisions
at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection
criteria covering a wide range of physics analysis needs have been examined.
For all considered selections, the efficiency to reconstruct and identify a
muon with a transverse momentum pT larger than a few GeV is above 95% over the
whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4,
while the probability to misidentify a hadron as a muon is well below 1%. The
efficiency to trigger on single muons with pT above a few GeV is higher than
90% over the full eta range, and typically substantially better. The overall
momentum scale is measured to a precision of 0.2% with muons from Z decays. The
transverse momentum resolution varies from 1% to 6% depending on pseudorapidity
for muons with pT below 100 GeV and, using cosmic rays, it is shown to be
better than 10% in the central region up to pT = 1 TeV. Observed distributions
of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
Azimuthal anisotropy of charged particles at high transverse momenta in PbPb collisions at sqrt(s[NN]) = 2.76 TeV
The azimuthal anisotropy of charged particles in PbPb collisions at
nucleon-nucleon center-of-mass energy of 2.76 TeV is measured with the CMS
detector at the LHC over an extended transverse momentum (pt) range up to
approximately 60 GeV. The data cover both the low-pt region associated with
hydrodynamic flow phenomena and the high-pt region where the anisotropies may
reflect the path-length dependence of parton energy loss in the created medium.
The anisotropy parameter (v2) of the particles is extracted by correlating
charged tracks with respect to the event-plane reconstructed by using the
energy deposited in forward-angle calorimeters. For the six bins of collision
centrality studied, spanning the range of 0-60% most-central events, the
observed v2 values are found to first increase with pt, reaching a maximum
around pt = 3 GeV, and then to gradually decrease to almost zero, with the
decline persisting up to at least pt = 40 GeV over the full centrality range
measured.Comment: Replaced with published version. Added journal reference and DO
- âŚ