863 research outputs found

    Can latent heat safely warm blood? – in vitro testing of a portable prototype blood warmer

    Get PDF
    This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.Background Trauma/retrieval patients are often in shock and hypothermic. Treatment of such patients usually involves restoring their blood volume with transfusion of blood (stored at 2°C – 6°C) and/or crystalloids or colloids (stored at ambient temperature). Rapid infusion of these cold fluids can worsen or even induce hypothermia in these patients. Warming of intravenous fluids at accident sites has traditionally been difficult due to a lack of suitable portable fluid warmers that are not dependent on mains electrical or battery power. If latent heat, the heat released when a liquid solidifies (an inherently temperature limiting process) can warm intravenous fluids, portable devices without a reliance on electrical energy could be used to reduce the incidence of hypothermia in trauma patients. Methods Rapid infusion of red cells into patients was timed to sample typical clinical flow rates. An approved dry heat blood warmer was compared with a prototype blood warmer using a supercooled liquid latent heat storage material, to warm red cells whilst monitoring inlet and outlet temperatures. To determine the effect of warming on red cell integrity compared to the normal storage lesion of blood, extracellular concentrations of potassium, lactate dehydrogenase and haemoglobin were measured in blood which had been warmed after storage at 2°C – 6°C for 1 to 42 days. Results A prototype latent heat fluid warmer consistently warmed red cells from approximately 4°C to approximately 35°C at typical clinical flow rates. Warming of stored blood with latent heat did not affect red cell integrity more than the approved dry heat blood warmer. Conclusion Using latent heat as an energy source can satisfactorily warm cold blood or other intravenous fluids to near body temperature, without any adverse affects

    Mechanical performance of fly ash geopolymeric mortars containing phase change materials

    Get PDF
    European Union (EU) aims to achieve nearly zero-energy (public) building (NZEB)  by the end of 2018. This very ambitious target would be more easily fulfilled if high- thermal performance materials like phase change materials (PCMs) are to be used.  This paper reports experimental results on the mechanical properties of  geopolymeric mortars containing PCMs at ambient temperature and after exposure  to high temperature. The results show that the inclusion of PCMs is responsible for a  reduction of the mechanical strength of the mortars. Several mixtures showed an  increase in compressive strength after being exposed to high temperatures. Since  PCMs are made of flammable materials, geopolymeric mortars are more advantageous than Portland cement-based mortars for PCM incorporation.info:eu-repo/semantics/publishedVersio

    Topology and Wilson lines: global aspects of the double copy

    Get PDF
    The Kerr-Schild double copy relates exact solutions of gauge and gravity theories. In all previous examples, the gravity solution is associated with an abelian-like gauge theory object, which linearises the Yang-Mills equations. This appears to be at odds with the double copy for scattering amplitudes, in which the non-abelian nature of the gauge theory plays a crucial role. Furthermore, it is not yet clear whether or not global properties of classical fields - such as non-trivial topology - can be matched between gauge and gravity theories. In this paper, we clarify these issues by explicitly demonstrating how magnetic monopoles associated with arbitrary gauge groups can be double copied to the same solution (the pure NUT metric) in gravity. We further describe how to match up topological information on both sides of the double copy correspondence, independently of the nature of the gauge group. This information is neatly expressed in terms of Wilson line operators, and we argue through specific examples that they provide a useful bridge between the classical double copy and the BCJ double copy for scattering amplitudes.Comment: 31 pages, 4 figures. Some minor corrections have been implemente

    The clinical presentation of preterm cerebellar haemorrhage

    Get PDF
    The objective of this study was to evaluate clinical symptoms and findings on cranial ultrasound (CUS) in preterm infants with cerebellar haemorrhage through retrospective analysis of all preterm infants with a postnatal CUS or MRI diagnosis of cerebellar haemorrhage admitted in a tertiary care centre between January 2002 and June 2009. Fifteen infants were identified; median gestational age was 25 2/7 weeks and median birth weight 730 g. We discerned six types of haemorrhage: subarachnoid (n=3), folial (n=1), lobar (n=9, of which 4 bilateral), giant lobar (n=1, including vermis) and contusional (n=1). Especially in infants with lobar cerebellar haemorrhage, CUS showed preceding or concurrent lateral ventricle dilatation, mostly without intraventricular haemorrhage (IVH). Thirteen infants suffered from notable, otherwise unexplained motor agitation in the days preceding the diagnosis. In conclusion, motor agitation may be a presenting symptom of cerebellar haemorrhage in preterm infants. Unexplained ventriculomegaly can be a first sign of cerebellar haemorrhage and should instigate sonographic exploration of the cerebellum

    A review of wearable motion tracking systems used in rehabilitation following hip and knee replacement

    Get PDF
    Clinical teams are under increasing pressure to facilitate early hospital discharge for total hip replacement and total knee replacement patients following surgery. A wide variety of wearable devices are being marketed to assist with rehabilitation following surgery. A review of wearable devices was undertaken to assess the evidence supporting their efficacy in assisting rehabilitation following total hip replacement and total knee replacement. A search was conducted using the electronic databases including Medline, CINAHL, Cochrane, PsycARTICLES, and PubMed of studies from January 2000 to October 2017. Five studies met the eligibility criteria, and all used an accelerometer and a gyroscope for their technology. A review of the studies found very little evidence to support the efficacy of the technology, although they show that the use of the technology is feasible. Future work should establish which wearable technology is most valuable to patients, which ones improve patient outcomes, and the most economical model for deploying the technolog

    Observation of the Baryonic Flavor-Changing Neutral Current Decay Lambda_b -> Lambda mu+ mu-

    Get PDF
    We report the first observation of the baryonic flavor-changing neutral current decay Lambda_b -> Lambda mu+ mu- with 24 signal events and a statistical significance of 5.8 Gaussian standard deviations. This measurement uses ppbar collisions data sample corresponding to 6.8fb-1 at sqrt{s}=1.96TeV collected by the CDF II detector at the Tevatron collider. The total and differential branching ratios for Lambda_b -> Lambda mu+ mu- are measured. We find B(Lambda_b -> Lambda mu+ mu-) = [1.73+-0.42(stat)+-0.55(syst)] x 10^{-6}. We also report the first measurement of the differential branching ratio of B_s -> phi mu+ mu- using 49 signal events. In addition, we report branching ratios for B+ -> K+ mu+ mu-, B0 -> K0 mu+ mu-, and B -> K*(892) mu+ mu- decays.Comment: 8 pages, 2 figures, 4 tables. Submitted to Phys. Rev. Let
    corecore