155 research outputs found

    National survey of summertime temperatures and overheating risk in English homes

    Get PDF
    AbstractThis paper presents one of the first national scale studies of summertime temperatures in English dwellings. Living room and bedroom temperatures were recorded in 207 homes across the England during the cool summer of 2007. Data was also collected by face-to-face household interviews. Fourteen homes (7%) were observed to be heated for part or all of the analysis period (July to August). Based on the BSEN15251 adaptive thermal comfort model, the 193 free-running dwellings would, in general, to be considered as uncomfortably cool. Over 72% of living rooms and bedrooms had more than 5% of hours below the BSEN15251 Cat II lower threshold, with over 50% having more than 5% of hours below the Cat III threshold. Detached homes and those built before 1919 were significantly cooler (p < 0.05) than those of other type and age. Static criteria revealed that, despite the cool summer, 21% of the bedrooms had more than 5% of night time hours over 26 °C; which is a recommended upper limit for bedrooms. The bedrooms of modern homes, i.e. those built after 1990 or with cavity walls, were significantly warmer (p < 0.05). The bedrooms in homes built prior to 1919 were significantly cooler (p < 0.05). The living rooms of flats were significantly warmer than the living rooms in the other dwelling types (p < 0.05). The incidence of warm bedrooms in modern homes, even during a cool summer, is of concern, especially as there is a strong trend towards even better insulation standards in new homes and the energy-efficient retrofitting of existing homes

    The influence of hospital ward design on resilience to heat waves: An exploration using distributed lag models

    Get PDF
    Distributed lag models (DLMs) to predict future internal temperatures have been developed using the hourly weather data and the internal temperatures recorded in eleven spaces on two UK National Health Service (NHS) hospital sites. The ward spaces were in five buildings of very different type and age. In all the DLMs, the best prediction of internal temperature was obtained using three exogenous drivers, previous internal temperature, external temperature and solar radiation. DLMs were sensitive to the buildings’ differences in orientation, thermal mass and shading and were validated by comparing the predictions with the internal temperatures recorded in the summer of 2012. The results were encouraging, with both modelled and recorded data showing good correlation. To understand the resilience of the spaces to heat waves, the DLMs were fed with weather data recorded during the hot summer of 2006. The Nightingale wards and traditional masonry wards showed remarkable resilience to the hot weather. In contrast, light-weight modular buildings were predicted to overheat dangerously. By recording internal temperatures for a short period, DLMs might be created that can forecast future temperatures in many other types of naturally ventilated or mixed-mode buildings as a means of assessing overheating ris

    Hospital wards and modular construction: Summertime overheating and energy efficiency

    Get PDF
    The UK National Health Service (NHS) is continually under pressure to provide more bed spaces and to do this within a tight budget. Therefore, NHS Trusts may turn to modular buildings, which promise faster construction and low energy demands helping the NHS meet its stringent energy targets. However, there is growing evidence that thermally lightweight, well insulated and naturally ventilated dwellings are at risk of overheating during warm UK summers. This paper examines the energy demands and internal temperatures in two 16-bed hospital wards built in 2008?at Bradford Royal Infirmary in northern England using modular fast track methods. The two-storey building used ceiling-mounted radiant panels and a mix of natural and mechanical ventilation with heat recovery to condition patients' rooms. Monitoring showed that the annual energy demand was 289?kWh/m2 ±16%, which is below the NHS guidelines for new hospital buildings. It was observed that the criterion given in Department of Health Technical Memorandum HTM03-01 can lead to the incorrect diagnosis of overheating risk in existing buildings. Assessment using other static and adaptive overheating criteria showed that patient rooms and the nurses' station overheated in summer. To maintain patient safety, temporary air conditioning units had to be installed during the warmest weather. It is concluded that thermally lightweight, well insulated, naturally ventilated hospital wards can be low-energy but are at risk of overheating even in relatively cool UK summer conditions and that this needs to be addressed before such buildings can be recommended for wider adoption

    An automated high-throughput system for phenotypic screening of chemical libraries on C. elegans and parasitic nematodes

    Get PDF
    Parasitic nematodes infect hundreds of millions of people and farmed livestock. Further, plant parasitic nematodes result in major crop damage. The pipeline of therapeutic compounds is limited and parasite resistance to the existing anthelmintic compounds is a global threat. We have developed an INVertebrate Automated Phenotyping Platform (INVAPP) for high-throughput, plate-based chemical screening, and an algorithm (Paragon) which allows screening for compounds that have an effect on motility and development of parasitic worms. We have validated its utility by determining the efficacy of a panel of known anthelmintics against model and parasitic nematodes: Caenorhabditis elegans, Haemonchus contortus, Teladorsagia circumcincta, and Trichuris muris. We then applied the system to screen the Pathogen Box chemical library in a blinded fashion and identified compounds already known to have anthelmintic or anti-parasitic activity, including tolfenpyrad, auranofin, and mebendazole; and 14 compounds previously undescribed as anthelmintics, including benzoxaborole and isoxazole chemotypes. This system offers an effective, high-throughput system for the discovery of novel anthelmintics

    Automated dynamic thermal simulation of houses and housing stocks using readily available reduced data

    Get PDF
    This paper describes a new method to swiftly model the dynamics of heating energy demand and indoor air temperatures of houses and housing stocks. The Reduced data Energy Model (RdDEM) provides a cost-effective alternative to steady-state modelling by enhancing the input dataset from the Reduced data Standard Assessment Procedure (RdSAP) – the method used to calculate Energy Performance Certificates (EPC) in the UK. This eliminates the main drawbacks associated with dynamic thermal simulation (DTS) of housing stocks, namely the large amount of required input data and the significant time required to model each house. The RdDEM algorithms create RdSAP-equivalent geometry, construction, thermal mass and boundary conditions in Energy Plus DTS software. The new inferences and methodological enhancements were first tested and then implemented at scale using a sample of 83 semi-detached houses. Most energy results from RdDEM were within 10% of those from RdSAP. The differences are explained by the different ways that indoor air temperature is calculated. The RdDEM method provides a dynamic alternative to RdSAP for understanding the dynamics of energy demand and indoor air temperatures in homes. This could include assessing the peak demand of a community energy scheme or assessing the summertime overheating risk in individual dwellings. Ultimately, it could provide a dynamic housing stock model using the data already collected from millions of houses to generate EPCs

    Measurement and analysis of household carbon: the case of a UK city

    Get PDF
    There is currently a lack of data recording the carbon and emissions inventory at household level. This paper presents a multi-disciplinary, bottom-up approach for estimation and analysis of the carbon emissions, and the organic carbon (OC) stored in gardens, using a sample of 575 households across a UK city. The annual emission of carbon dioxide emissions from energy used in the homes was measured, personal transport emissions were assessed through a household survey and OC stores estimated from soil sampling and vegetation surveys. The results showed that overall carbon patterns were skewed with highest emitting third of the households being responsible for more than 50% of the emissions and around 50% of garden OC storage. There was diversity in the relative contribution that gas, electricity and personal transport made to each household’s total and different patterns were observed for high, medium and low emitting households. Targeting households with high carbon emissions from one source would not reliably identify them as high emitters overall. While carbon emissions could not be offset by growing trees in gardens, there were considerable amounts of stored OC in gardens which ought to be protected. Exploratory analysis of the multiple drivers of emissions was conducted using a combination of primary and secondary data. These findings will be relevant in devising effective policy instruments for combatting city scale green-house gas emissions from domestic end-use energy demand

    On the mechanisms governing gas penetration into a tokamak plasma during a massive gas injection

    Get PDF
    A new 1D radial fluid code, IMAGINE, is used to simulate the penetration of gas into a tokamak plasma during a massive gas injection (MGI). The main result is that the gas is in general strongly braked as it reaches the plasma, due to mechanisms related to charge exchange and (to a smaller extent) recombination. As a result, only a fraction of the gas penetrates into the plasma. Also, a shock wave is created in the gas which propagates away from the plasma, braking and compressing the incoming gas. Simulation results are quantitatively consistent, at least in terms of orders of magnitude, with experimental data for a D 2 MGI into a JET Ohmic plasma. Simulations of MGI into the background plasma surrounding a runaway electron beam show that if the background electron density is too high, the gas may not penetrate, suggesting a possible explanation for the recent results of Reux et al in JET (2015 Nucl. Fusion 55 093013)

    Velocity-space sensitivity of the time-of-flight neutron spectrometer at JET

    Get PDF
    The velocity-space sensitivities of fast-ion diagnostics are often described by so-called weight functions. Recently, we formulated weight functions showing the velocity-space sensitivity of the often dominant beam-target part of neutron energy spectra. These weight functions for neutron emission spectrometry (NES) are independent of the particular NES diagnostic. Here we apply these NES weight functions to the time-of-flight spectrometer TOFOR at JET. By taking the instrumental response function of TOFOR into account, we calculate time-of-flight NES weight functions that enable us to directly determine the velocity-space sensitivity of a given part of a measured time-of-flight spectrum from TOFOR

    Relationship of edge localized mode burst times with divertor flux loop signal phase in JET

    Get PDF
    A phase relationship is identified between sequential edge localized modes (ELMs) occurrence times in a set of H-mode tokamak plasmas to the voltage measured in full flux azimuthal loops in the divertor region. We focus on plasmas in the Joint European Torus where a steady H-mode is sustained over several seconds, during which ELMs are observed in the Be II emission at the divertor. The ELMs analysed arise from intrinsic ELMing, in that there is no deliberate intent to control the ELMing process by external means. We use ELM timings derived from the Be II signal to perform direct time domain analysis of the full flux loop VLD2 and VLD3 signals, which provide a high cadence global measurement proportional to the voltage induced by changes in poloidal magnetic flux. Specifically, we examine how the time interval between pairs of successive ELMs is linked to the time-evolving phase of the full flux loop signals. Each ELM produces a clear early pulse in the full flux loop signals, whose peak time is used to condition our analysis. The arrival time of the following ELM, relative to this pulse, is found to fall into one of two categories: (i) prompt ELMs, which are directly paced by the initial response seen in the flux loop signals; and (ii) all other ELMs, which occur after the initial response of the full flux loop signals has decayed in amplitude. The times at which ELMs in category (ii) occur, relative to the first ELM of the pair, are clustered at times when the instantaneous phase of the full flux loop signal is close to its value at the time of the first ELM

    Overview of the JET results in support to ITER

    Get PDF
    corecore