52 research outputs found

    Sexy Technical Communication

    Get PDF
    Sexy technical writing…we’ve got to be kidding, right? But no, we aren’t. Good technical writing is powerful and clear and gets the job done. It brings people together and solves problems. Good technical writing purrs and hums like that BMW you plan to be driving someday.What’s not sexy about that? On the other hand, poor technical writing skills may lead to a lifetime of asking people if they want fries with that…or worse, selling vacuum cleaners door to door. There’s no need to ask what’s not sexy about that! WE – your textbook authors – are a team of dedicated writers, tech writing teachers, designers, artists and professionals who are absolutely passionate about technical writing. That’s why we decided to create a text for you that we all loved, a text that would be free and always available to you. Now, that’s sexy. We hope you love what we have done as much as we have loved doing it…and notice…we haven’t even asked for a donation!https://digitalcommons.kennesaw.edu/facbooks2016/1005/thumbnail.jp

    Using Probe Data Analytics for Assessing Freeway Speed Reductions During Rain Events

    Get PDF
    Rain impacts roadways such as wet pavement, standing water, decreased visibility, and wind gusts and can lead to hazardous driving conditions. This study investigates the use of high fidelity Doppler data at 1 km spatial and 2-minute temporal resolution in combination with commercial probe speed data on freeways. Segment-based space-mean speeds were used and drops in speeds during rainfall events of 5.5 mm/hour or greater over a one-month period on a section of four to six-lane interstate were assessed. Speed reductions were evaluated as a time series over a 1-hour window with the rain data. Three interpolation methods for estimating rainfall rates were tested and seven metrics were developed for the analysis. The study found sharp drops in speed of more than 40 mph occurred at estimated rainfall rates of 30 mm/hour or greater, but the drops did not become more severe beyond this threshold. The average time of first detected rainfall to impacting speeds was 17 minutes. The bilinear method detected the greatest number of events during the 1-month period, with the most conservative rate of predicted rainfall. The range of rainfall intensities were estimated between 7.5 to 106 mm/hour for the 39 events. This range was much greater than the heavy rainfall categorization at 16 mm/hour in previous studies reported in the literature. The bilinear interpolation method for Doppler data is recommended because it detected the greatest number of events and had the longest rain duration and lowest estimated maximum rainfall out of three methods tested, suggesting the method balanced awareness of the weather conditions around the roadway with isolated, localized rain intensities

    Technical Communication

    Get PDF
    This Grants Collection for Technical Communication was created under a Round Three ALG Textbook Transformation Grant. Affordable Learning Georgia Grants Collections are intended to provide faculty with the frameworks to quickly implement or revise the same materials as a Textbook Transformation Grants team, along with the aims and lessons learned from project teams during the implementation process. Documents are in .pdf format, with a separate .docx (Word) version available for download. Each collection contains the following materials: Linked Syllabus Initial Proposal Final Reporthttps://oer.galileo.usg.edu/communication-collections/1004/thumbnail.jp

    Department of Music Student Symposium Recital

    Get PDF
    The 2015 Annual Student Symposium Recital features students from the Department of Music nominated by the music faculty to recognize excellence in scholarship and creative achievement. The performance includes selections from senior capstones in music (senior recitals, projects, lecture-recitals, theses), original music compositions, music performed for competitions, original dance choreography, and faculty-student collaborative chamber music works

    Chemical Power for Microscopic Robots in Capillaries

    Full text link
    The power available to microscopic robots (nanorobots) that oxidize bloodstream glucose while aggregated in circumferential rings on capillary walls is evaluated with a numerical model using axial symmetry and time-averaged release of oxygen from passing red blood cells. Robots about one micron in size can produce up to several tens of picowatts, in steady-state, if they fully use oxygen reaching their surface from the blood plasma. Robots with pumps and tanks for onboard oxygen storage could collect oxygen to support burst power demands two to three orders of magnitude larger. We evaluate effects of oxygen depletion and local heating on surrounding tissue. These results give the power constraints when robots rely entirely on ambient available oxygen and identify aspects of the robot design significantly affecting available power. More generally, our numerical model provides an approach to evaluating robot design choices for nanomedicine treatments in and near capillaries.Comment: 28 pages, 7 figure

    Reproducibility of arterial spin labeling cerebral blood flow image processing:A report of the ISMRM open science initiative for perfusion imaging (OSIPI) and the ASL MRI challenge

    Get PDF
    Purpose: Arterial spin labeling (ASL) is a widely used contrast-free MRI method for assessing cerebral blood flow (CBF). Despite the generally adopted ASL acquisition guidelines, there is still wide variability in ASL analysis. We explored this variability through the ISMRM-OSIPI ASL-MRI Challenge, aiming to establish best practices for more reproducible ASL analysis. Methods: Eight teams analyzed the challenge data, which included a high-resolution T1-weighted anatomical image and 10 pseudo-continuous ASL datasets simulated using a digital reference object to generate ground-truth CBF values in normal and pathological states. We compared the accuracy of CBF quantification from each team's analysis to the ground truth across all voxels and within predefined brain regions. Reproducibility of CBF across analysis pipelines was assessed using the intra-class correlation coefficient (ICC), limits of agreement (LOA), and replicability of generating similar CBF estimates from different processing approaches. Results: Absolute errors in CBF estimates compared to ground-truth synthetic data ranged from 18.36 to 48.12 mL/100 g/min. Realistic motion incorporated into three datasets produced the largest absolute error and variability between teams, with the least agreement (ICC and LOA) with ground-truth results. Fifty percent of the submissions were replicated, and one produced three times larger CBF errors (46.59 mL/100 g/min) compared to submitted results. Conclusions: Variability in CBF measurements, influenced by differences in image processing, especially to compensate for motion, highlights the significance of standardizing ASL analysis workflows. We provide a recommendation for ASL processing based on top-performing approaches as a step toward ASL standardization.</p

    Reproducibility of arterial spin labeling cerebral blood flow image processing: a report of the ISMRM open science initiative for perfusion imaging (OSIPI) and the ASL MRI challenge

    Get PDF
    Purpose: Arterial spin labeling (ASL) is a widely used contrast-free MRI method for assessing cerebral blood flow (CBF). Despite the generally adopted ASL acquisition guidelines, there is still wide variability in ASL analysis. We explored this variability through the ISMRM-OSIPI ASL-MRI Challenge, aiming to establish best practices for more reproducible ASL analysis. Methods: Eight teams analyzed the challenge data, which included a high-resolution T1-weighted anatomical image and 10 pseudo-continuous ASL datasets simulated using a digital reference object to generate ground-truth CBF values in normal and pathological states. We compared the accuracy of CBF quantification from each team's analysis to the ground truth across all voxels and within predefined brain regions. Reproducibility of CBF across analysis pipelines was assessed using the intra-class correlation coefficient (ICC), limits of agreement (LOA), and replicability of generating similar CBF estimates from different processing approaches. Results: Absolute errors in CBF estimates compared to ground-truth synthetic data ranged from 18.36 to 48.12 mL/100 g/min. Realistic motion incorporated into three datasets produced the largest absolute error and variability between teams, with the least agreement (ICC and LOA) with ground-truth results. Fifty percent of the submissions were replicated, and one produced three times larger CBF errors (46.59 mL/100 g/min) compared to submitted results. Conclusions: Variability in CBF measurements, influenced by differences in image processing, especially to compensate for motion, highlights the significance of standardizing ASL analysis workflows. We provide a recommendation for ASL processing based on top-performing approaches as a step toward ASL standardization

    Reproducibility of arterial spin labeling cerebral blood flow image processing:A report of the ISMRM open science initiative for perfusion imaging (OSIPI) and the ASL MRI challenge

    Get PDF
    Purpose: Arterial spin labeling (ASL) is a widely used contrast-free MRI method for assessing cerebral blood flow (CBF). Despite the generally adopted ASL acquisition guidelines, there is still wide variability in ASL analysis. We explored this variability through the ISMRM-OSIPI ASL-MRI Challenge, aiming to establish best practices for more reproducible ASL analysis. Methods: Eight teams analyzed the challenge data, which included a high-resolution T1-weighted anatomical image and 10 pseudo-continuous ASL datasets simulated using a digital reference object to generate ground-truth CBF values in normal and pathological states. We compared the accuracy of CBF quantification from each team's analysis to the ground truth across all voxels and within predefined brain regions. Reproducibility of CBF across analysis pipelines was assessed using the intra-class correlation coefficient (ICC), limits of agreement (LOA), and replicability of generating similar CBF estimates from different processing approaches. Results: Absolute errors in CBF estimates compared to ground-truth synthetic data ranged from 18.36 to 48.12 mL/100 g/min. Realistic motion incorporated into three datasets produced the largest absolute error and variability between teams, with the least agreement (ICC and LOA) with ground-truth results. Fifty percent of the submissions were replicated, and one produced three times larger CBF errors (46.59 mL/100 g/min) compared to submitted results. Conclusions: Variability in CBF measurements, influenced by differences in image processing, especially to compensate for motion, highlights the significance of standardizing ASL analysis workflows. We provide a recommendation for ASL processing based on top-performing approaches as a step toward ASL standardization.</p

    Modulation of β-Catenin Signaling by Glucagon Receptor Activation

    Get PDF
    The glucagon receptor (GCGR) is a member of the class B G protein–coupled receptor family. Activation of GCGR by glucagon leads to increased glucose production by the liver. Thus, glucagon is a key component of glucose homeostasis by counteracting the effect of insulin. In this report, we found that in addition to activation of the classic cAMP/protein kinase A (PKA) pathway, activation of GCGR also induced β-catenin stabilization and activated β-catenin–mediated transcription. Activation of β-catenin signaling was PKA-dependent, consistent with previous reports on the parathyroid hormone receptor type 1 (PTH1R) and glucagon-like peptide 1 (GLP-1R) receptors. Since low-density-lipoprotein receptor–related protein 5 (Lrp5) is an essential co-receptor required for Wnt protein mediated β-catenin signaling, we examined the role of Lrp5 in glucagon-induced β-catenin signaling. Cotransfection with Lrp5 enhanced the glucagon-induced β-catenin stabilization and TCF promoter–mediated transcription. Inhibiting Lrp5/6 function using Dickkopf-1(DKK1) or by expression of the Lrp5 extracellular domain blocked glucagon-induced β-catenin signaling. Furthermore, we showed that Lrp5 physically interacted with GCGR by immunoprecipitation and bioluminescence resonance energy transfer assays. Together, these results reveal an unexpected crosstalk between glucagon and β-catenin signaling, and may help to explain the metabolic phenotypes of Lrp5/6 mutations
    • …
    corecore