101 research outputs found

    Should we individualize training based on force-velocity profiling to improve physical performance in athletes?

    Get PDF
    The present study aimed to examine the effectiveness of an individualized training program based on force-velocity (FV) profiling on jumping, sprinting, strength, and power in athletes. Forty national level team sport athletes (20 ± 4years, 83 ± 13 kg) from ice-hockey, handball, and soccer completed a 10-week training intervention. A theoretical optimal squat jump (SJ)-FV-profile was calculated from SJ with five different loads (0, 20, 40, 60, and 80 kg). Based on their initial FV-profile, athletes were randomized to train toward, away, or irrespective (balanced training) of their initial theoretical optimal FV-profile. The training content was matched between groups in terms of set x repetitions but varied in relative loading to target the different aspects of the FV-profile. The athletes performed 10 and 30 m sprints, SJ and countermovement jump (CMJ), 1 repetition maximum (1RM) squat, and a leg-press power test before and after the intervention. There were no significant group differences for any of the performance measures. Trivial to small changes in 1RM squat (2.9%, 4.6%, and 6.5%), 10 m sprint time (1.0%, −0.9%, and −1.7%), 30 m sprint time (0.9%, −0.6%, and −0.4%), CMJ height (4.3%, 3.1%, and 5.7%), SJ height (4.8%, 3.7%, and 5.7%), and leg-press power (6.7%, 4.2%, and 2.9%) were observed in the groups training toward, away, or irrespective of their initial theoretical optimal FV-profile, respectively. Changes toward the optimal SJ-FV-profile were negatively correlated with changes in SJ height (r = −0.49, p < 0.001). Changes in SJ-power were positively related to changes in SJ-height (r = 0.88, p < 0.001) and CMJ-height (r = 0.32, p = 0.044), but unrelated to changes in 10 m (r = −0.02, p = 0.921) and 30 m sprint time (r = −0.01, p = 0.974). The results from this study do not support the efficacy of individualized training based on SJ-FV profiling.publishedVersio

    Periprosthetic Joint Infection After Total Knee Arthroplasty With or Without Antibiotic Bone Cement.

    Get PDF
    IMPORTANCE Despite increased use of antibiotic-loaded bone cement (ALBC) in joint arthroplasty over recent decades, current evidence for prophylactic use of ALBC to reduce risk of periprosthetic joint infection (PJI) is insufficient. OBJECTIVE To compare the rate of revision attributed to PJI following primary total knee arthroplasty (TKA) using ALBC vs plain bone cement. DESIGN, SETTING, AND PARTICIPANTS This international cohort study used data from 14 national or regional joint arthroplasty registries in Australia, Denmark, Finland, Germany, Italy, New Zealand, Norway, Romania, Sweden, Switzerland, the Netherlands, the UK, and the US. The study included primary TKAs for osteoarthritis registered from January 1, 2010, to December 31, 2020, and followed-up until December 31, 2021. Data analysis was performed from April to September 2023. EXPOSURE Primary TKA with ALBC vs plain bone cement. MAIN OUTCOMES AND MEASURES The primary outcome was risk of 1-year revision for PJI. Using a distributed data network analysis method, data were harmonized, and a cumulative revision rate was calculated (1 - Kaplan-Meier), and Cox regression analyses were performed within the 10 registries using both cement types. A meta-analysis was then performed to combine all aggregated data and evaluate the risk of 1-year revision for PJI and all causes. RESULTS Among 2 168 924 TKAs included, 93% were performed with ALBC. Most TKAs were performed in female patients (59.5%) and patients aged 65 to 74 years (39.9%), fully cemented (92.2%), and in the 2015 to 2020 period (62.5%). All participating registries reported a cumulative 1-year revision rate for PJI of less than 1% following primary TKA with ALBC (range, 0.21%-0.80%) and with plain bone cement (range, 0.23%-0.70%). The meta-analyses based on adjusted Cox regression for 1 917 190 TKAs showed no statistically significant difference at 1 year in risk of revision for PJI (hazard rate ratio, 1.16; 95% CI, 0.89-1.52) or for all causes (hazard rate ratio, 1.12; 95% CI, 0.89-1.40) among TKAs performed with ALBC vs plain bone cement. CONCLUSIONS AND RELEVANCE In this study, the risk of revision for PJI was similar between ALBC and plain bone cement following primary TKA. Any additional costs of ALBC and its relative value in reducing revision risk should be considered in the context of the overall health care delivery system

    The use of antibiotic-loaded bone cement and systemic antibiotic prophylactic use in 2,971,357 primary total knee arthroplasties from 2010 to 2020: an international register-based observational study among countries in Africa, Europe, North America, and Oceania.

    Get PDF
    BACKGROUND AND PURPOSE Antibiotic-loaded bone cement (ALBC) and systemic antibiotic prophylaxis (SAP) have been used to reduce periprosthetic joint infection (PJI) rates. We investigated the use of ALBC and SAP in primary total knee arthroplasty (TKA). PATIENTS AND METHODS This observational study is based on 2,971,357 primary TKAs reported in 2010-2020 to national/regional joint arthroplasty registries in Australia, Denmark, Finland, Germany, Italy, the Netherlands, New Zealand, Norway, Romania, South Africa, Sweden, Switzerland, the UK, and the USA. Aggregate-level data on trends and types of bone cement, antibiotic agents, and doses and duration of SAP used was extracted from participating registries. RESULTS ALBC was used in 77% of the TKAs with variation ranging from 100% in Norway to 31% in the USA. Palacos R+G was the most common (62%) ALBC type used. The primary antibiotic used in ALBC was gentamicin (94%). Use of ALBC in combination with SAP was common practice (77%). Cefazolin was the most common (32%) SAP agent. The doses and duration of SAP used varied from one single preoperative dosage as standard practice in Bolzano, Italy (98%) to 1-day 4 doses in Norway (83% of the 40,709 TKAs reported to the Norwegian arthroplasty register). CONCLUSION The proportion of ALBC usage in primary TKA varies internationally, with gentamicin being the most common antibiotic. ALBC in combination with SAP was common practice, with cefazolin the most common SAP agent. The type of ALBC and type, dose, and duration of SAP varied among participating countries

    Is There a Place for Dietary Fiber Supplements in Weight Management?

    Get PDF
    Inadequate dietary fiber intake is common in modern diets, especially in children. Epidemiological and experimental evidence point to a significant association between a lack of fiber intake and ischemic heart disease, stroke atherosclerosis, type 2 diabetes, overweight and obesity, insulin resistance, hypertension, dyslipidemia, as well as gastrointestinal disorders such as diverticulosis, irritable bowel disease, colon cancer, and cholelithiasis. The physiological effects of fiber relate to the physical properties of volume, viscosity, and water-holding capacity that the fiber imparts to food leading to important influences over the energy density of food. Beyond these physical properties, fiber directly impacts a complex array of microbiological, biochemical, and neurohormonal effects directly through modification of the kinetics of digestion and through its metabolism into constituents such as short chain fatty acids, which are both energy substrates and important enteroendocrine ligands. Of particular interest to clinicians is the important role dietary fiber plays in glucoregulation, appetite, and satiety. Supplementation of the diet with highly functional fibers may prove to play an important role in long-term obesity management

    Application of infrared thermography in computer aided diagnosis

    Get PDF
    The invention of thermography, in the 1950s, posed a formidable problem to the research community: What is the relationship between disease and heat radiation captured with Infrared (IR) cameras? The research community responded with a continuous effort to find this crucial relationship. This effort was aided by advances in processing techniques, improved sensitivity and spatial resolution of thermal sensors. However, despite this progress fundamental issues with this imaging modality still remain. The main problem is that the link between disease and heat radiation is complex and in many cases even non-linear. Furthermore, the change in heat radiation as well as the change in radiation pattern, which indicate disease, is minute. On a technical level, this poses high requirements on image capturing and processing. On a more abstract level, these problems lead to inter-observer variability and on an even more abstract level they lead to a lack of trust in this imaging modality. In this review, we adopt the position that these problems can only be solved through a strict application of scientific principles and objective performance assessment. Computing machinery is inherently objective; this helps us to apply scientific principles in a transparent way and to assess the performance results. As a consequence, we aim to promote thermography based Computer-Aided Diagnosis (CAD) systems. Another benefit of CAD systems comes from the fact that the diagnostic accuracy is linked to the capability of the computing machinery and, in general, computers become ever more potent. We predict that a pervasive application of computers and networking technology in medicine will help us to overcome the shortcomings of any single imaging modality and this will pave the way for integrated health care systems which maximize the quality of patient care
    • …
    corecore