11 research outputs found

    Quality control concept and recent developments of the light climatic observatory at Arosa: Ozone measuring station of the Swiss Meteorological Institute (LKO)

    Get PDF
    Total ozone observations of two Dobson instruments (D15 and D101, C- and AD wavelength pair observations) and of two Brewer instruments (Br40 and Br72) are currently performed at the LKO at Arosa. A quality control concept is presented in order to make best use of the large number of quasi-simultaneous measurements. The longest ozone series of the world is mainly based on the measurements of the Dobson instrument D15 (wavelength pair C). Since the last years D15 has suffered from instrumental problems. The transformation of the longterm series to the measurements of D101(AD) is described

    An Automated Method for Ozonesonde Calibration: New Insights

    No full text
    An automated method for preparation of the electrochemical concentration cell (ECC) ozonesonde is presented. Development of a computer-controlled system for preparation and calibration of the ECC is an improvement over the manual preparation method, and reduces subjectivity considerably. Preparation measurements in digital form aids analysis of the ECC before release and enhances post-flight data certification. Calibration of ozonesondes over a range of ozone concentrations between 0 mPA and 30 mPA is discussed. This presentation describes the automatic system, gives examples of calibrations. The automated system enables comparison of varying potassium iodide (KI) concentrations that should allow adjustment of earlier ozonesonde data obtained with different KT concentrations used since 1970, i.e., 2, 1.5, 1, and 0.5 percent. Preliminary results indicate ECC accuracy has a strong dependence on the electrolyte concentration and should not be considered linear with altitude

    Balloon-borne match measurements of midlatitude cirrus clouds

    No full text
    Observations of high supersaturations with respect to ice inside cirrus clouds with high ice water content (> 0.01 g kg−1) and high crystal number densities (> 1 cm−3) are challenging our understanding of cloud microphysics and of climate feedback processes in the upper troposphere. However, single measurements of a cloudy air mass provide only a snapshot from which the persistence of ice supersaturation cannot be judged. We introduce here the "cirrus match technique" to obtain information about the evolution of clouds and their saturation ratio. The aim of these coordinated balloon soundings is to analyze the same air mass twice. To this end the standard radiosonde equipment is complemented by a frost point hygrometer, "SnowWhite", and a particle backscatter detector, "COBALD" (Compact Optical Backscatter AerosoL Detector). Extensive trajectory calculations based on regional weather model COSMO (Consortium for Small-Scale Modeling) forecasts are performed for flight planning, and COSMO analyses are used as a basis for comprehensive microphysical box modeling (with grid scale of 2 and 7 km, respectively). Here we present the results of matching a cirrus cloud to within 2–15 km, realized on 8 June 2010 over Payerne, Switzerland, and a location 120 km downstream close to Zurich. A thick cirrus cloud was detected over both measurement sites. We show that in order to quantitatively reproduce the measured particle backscatter ratios, the small-scale temperature fluctuations not resolved by COSMO must be superimposed on the trajectories. The stochastic nature of the fluctuations is captured by ensemble calculations. Possibilities for further improvements in the agreement with the measured backscatter data are investigated by assuming a very slow mass accommodation of water on ice, the presence of heterogeneous ice nuclei, or a wide span of (spheroidal) particle shapes. However, the resulting improvements from these microphysical refinements are moderate and comparable in magnitude with changes caused by assuming different regimes of temperature fluctuations for clear-sky or cloudy-sky conditions, highlighting the importance of proper treatment of subscale fluctuations. The model yields good agreement with the measured backscatter over both sites and reproduces the measured saturation ratios with respect to ice over Payerne. Conversely, the 30% in-cloud supersaturation measured in a massive 4 km thick cloud layer over Zurich cannot be reproduced, irrespective of the choice of meteorological or microphysical model parameters. The measured supersaturation can only be explained by either resorting to an unknown physical process, which prevents the ice particles from consuming the excess humidity, or – much more likely – by a measurement error, such as a contamination of the sensor housing of the SnowWhite hygrometer by a precipitation drop from a mixed-phase cloud just below the cirrus layer or from some very slight rain in the boundary layer. This uncertainty calls for in-flight checks or calibrations of hygrometers under the special humidity conditions in the upper troposphere.ISSN:1680-7375ISSN:1680-736

    The integumentary skeleton of tetrapods: origin, evolution, and development

    No full text
    Although often overlooked, the integument of many tetrapods is reinforced by a morphologically and structurally diverse assemblage of skeletal elements. These elements are widely understood to be derivatives of the once all-encompassing dermal skeleton of stem-gnathostomes but most details of their evolution and development remain confused and uncertain. Herein we re-evaluate the tetrapod integumentary skeleton by integrating comparative developmental and tissue structure data. Three types of tetrapod integumentary elements are recognized: (1) osteoderms, common to representatives of most major taxonomic lineages; (2) dermal scales, unique to gymnophionans; and (3) the lamina calcarea, an enigmatic tissue found only in some anurans. As presently understood, all are derivatives of the ancestral cosmoid scale and all originate from scleroblastic neural crest cells. Osteoderms are plesiomorphic for tetrapods but demonstrate considerable lineage-specific variability in size, shape, and tissue structure and composition. While metaplastic ossification often plays a role in osteoderm development, it is not the exclusive mode of skeletogenesis. All osteoderms share a common origin within the dermis (at or adjacent to the stratum superficiale) and are composed primarily (but not exclusively) of osseous tissue. These data support the notion that all osteoderms are derivatives of a neural crest-derived osteogenic cell population (with possible matrix contributions from the overlying epidermis) and share a deep homology associated with the skeletogenic competence of the dermis. Gymnophionan dermal scales are structurally similar to the elasmoid scales of most teleosts and are not comparable with osteoderms. Whereas details of development are lacking, it is hypothesized that dermal scales are derivatives of an odontogenic neural crest cell population and that skeletogenesis is comparable with the formation of elasmoid scales. Little is known about the lamina calcarea. It is proposed that this tissue layer is also odontogenic in origin, but clearly further study is necessary. Although not homologous as organs, all elements of the integumentary skeleton share a basic and essential relationship with the integument, connecting them with the ancestral rhombic scale

    The ontogeny of the shell in side-necked turtles, with emphasis on the homologies of costal and neural bones

    Full text link
    Although we are starting to understand the molecular basis of shell development based on the study of cryptodires, basic comparative ontogenetic data for the other major clade of living turtle, the pleurodires, are largely missing. Herein, the developmental and phylogenetic relation between the bony shell and endoskeleton of Pleurodira are examined by studying histological serial sections of nine specimens of three different species, including an ontogenetic series of Emydura subglobosa. Emphasis is given to the portion of the carapace in which ribs and vertebral spinous processes become part of the carapace. Central questions are how neurals and costals are formed in pleurodiran turtles, whether costals and neurals are of endoskeletal or exoskeletal origin, and what ontogenetic factors relate to neural reduction of some Pleurodira. The neurals and costals do not develop as independent ossification centers, but they are initial outgrowths of the periosteal collar of endoskeletal ribs and neural arches. Slightly later in development, the ossification of both shell elements continues without a distinct periosteum but by metaplastically ossifying precondensed soft-tissue integumentary structures. Through ontogeny, ribs of the turtles studied are closely associated with the hypaxial intercostalis musculature while epaxial interspinalis musculature connects the neural arches. We here propose an alternative structural hypothesis for the neural reduction and, ultimately, the complete loss of the neural series. The complete reduction of neurals in Emydura spp. may be linked to heterochrony, accompanied by a restricted influence of epaxial musculature and epidermal-dermal interaction in shell bone formatio

    Atmospheric comparison of electrochemical cell ozonesondes from different manufacturers, and with different cathode solution strenghts: The Balloon Experiment on Standards for Ozonesondes

    No full text
    A balloon flight to compare 18 ozonesondes with an ozone photometer and with ozone column measurements from Dobson and Brewer spectrophotometers was completed in April 2004. The core experiment consisted of 12 electrochemical concentration cell ozonesondes, 6 from Science Pump Corporation (SP) and 6 from ENSCI Corporation (ES), prepared with cathode solution concentrations of 0.5% KI (half buffer) and 1.0% KI (full buffer). Auxiliary ozonesondes consisted of two electrochemical concentration cell sondes with 2.0% KI (no buffer), two reconditioned sondes, and two Japanese-KC96 sondes. Precision of each group of similarly prepared ozonesondes was <2-3%. The six ozonesondes prepared according to the manufacturer's recommendations (SP, 1.0% KI, ES 0.5% KI) overestimated the photometer measurements by 5-10% in the stratosphere, but provided ozone columns in good agreement with the ground-based spectrophotometer measurements. This is consistent with the difference (similar to 5%) in ozone photometer and column measurements observed during the experiment. Using cathode cell concentrations of 1.0% KI for ES sondes caused overestimates of the photometer by 10-15% and of ozone column by 5-10%. In contrast, 0.5% KI in SP sondes led to good agreement with the photometer, but underestimates of ozone column. The KC96 sondes underestimated the photometer measurements by about 5-15% at air pressures above 30 hPa. Agreement was within 5% at lower pressures. Diluting the solution concentration and the buffers from 1.0% to 0.5% KI causes an approximately linear pressure-dependent decrease in ozone for both SP and ES sondes, ratio (0.5 KI/1.0 KI) = 0.9 + 0.024* log(10)(Pressure)

    SHADOZ (Southern Hemisphere Additional Ozonesondes) Ozone Climatology. 4. Tropospheric and Lower Stratospheric Profiles (2005-2009) with Comparisons to OMI Total Ozone

    Get PDF
    International audienceWe present a regional and seasonal climatology of SHADOZ ozone profiles in the troposphere and tropical tropopause layer (TTL) based on measurements taken during the first five years of Aura, 2005-2009, when new stations joined the network at Hanoi, Vietnam; Hilo, Hawaii; Alajuela/Heredia, Costa Rica; Cotonou, Benin. In all, 15 stations operated during that period. A west-to-east progression of decreasing convective influence and increasing pollution leads to distinct tropospheric ozone profiles in three regions: (1) western Pacific/eastern Indian Ocean; (2) equatorial Americas (San CristĂłbal, Alajuela, Paramaribo); (3) Atlantic and Africa. Comparisons in total ozone column from soundings, the Ozone Monitoring Instrument (OMI, on Aura, 2004-) satellite and ground-based instrumentation are presented. Most stations show better agreement with OMI than they did for EP/TOMS comparisons (1998-2004; Earth-Probe/Total Ozone Mapping Spectrometer), partly due to a revised above-burst ozone climatology. Possible station biases in the stratospheric segment of the ozone measurement noted in the first 7 years of SHADOZ ozone profiles are re-examined. High stratospheric bias observed during the TOMS period appears to persist at one station. Comparisons of SHADOZ tropospheric ozone and the daily Trajectory-enhanced Tropospheric Ozone Residual (TTOR) product (based on OMI/MLS) show that the satellite-derived column amount averages 25% low. Correlations between TTOR and the SHADOZ sondes are quite good (typical r2 = 0.5-0.8), however, which may account for why some published residual-based OMI products capture tropospheric interannual variability fairly realistically. On the other hand, no clear explanations emerge for why TTOR-sonde discrepancies vary over a wide range at most SHADOZ sites
    corecore