35 research outputs found

    Influence of material alterations and machine impairment on throughput related sensor-based sorting performance

    Get PDF
    Experiments with sensor-based sorting (SBS) machinery provide insight into the effect of throughput rate and input composition on the sorting performance. For this purpose, material mixtures with certain compositions and particle size distributions were created from waste fractions and sorted at various throughput rates. To evaluate the sorting performance of the SBS unit (using near infrared technology) in dependence of the applied load, four assessment factors concerning the output fractions were studied: yield, product purity, recovery/product quantity and incorrectly discharged share of reject particles. The influences on the assessment parameters of light twodimensional (2D) particles in the input of a sorting stage and failing air valves in an SBS unit were evaluated for various input compositions at different throughput rates. It was found that a share of approximately 5 wt% 2D particles in the input had a similar negative effect on the yield as the malfunction of 20% of all air valves in an SBS machine at high throughput rates. Additionally, the failure of the air valves reduced the product purity of the sorting stage at increased throughput rates. Furthermore, qualitative observations concerning systematic effects of prior studies could be confirmed. Resulting graphs for a specific input composition of an SBS unit at varying throughput rates could be used to adjust the throughput rate to meet the exact demands for a sorting stage

    Expression of the IRTA1 receptor identifies intraepithelial and subepithelial marginal zone B cells of the mucosa-associated lymphoid tissue (MALT)

    Get PDF
    AbstractIRTA1 (immunoglobulin superfamily receptor translocation-associated 1) is a novel surface B-cell receptor related to Fc receptors, inhibitory receptor superfamily (IRS), and cell adhesion molecule (CAM) family members and we mapped for the first time its distribution in human lymphoid tissues, using newly generated specific antibodies. IRTA1 was selectively and consistently expressed by a B-cell population located underneath and within the tonsil epithelium and dome epithelium of Peyer patches (regarded as the anatomic equivalents of marginal zone). Similarly, in mucosa-associated lymphoid tissue (MALT) lymphomas IRTA1 was mainly expressed by tumor cells involved in lympho-epithelial lesions. In contrast, no or a low number of IRTA1+ cells was usually observed in the marginal zone of mesenteric lymph nodes and spleen. Interestingly, monocytoid B cells in reactive lymph nodes were strongly IRTA1+. Tonsil IRTA1+ cells expressed the memory B-cell marker CD27 but not mantle cell-, germinal center-, and plasma cell-associated molecules. Polymerase chain reaction (PCR) analysis of single tonsil IRTA1+ cells showed they represent a mixed B-cell population carrying mostly mutated, but also unmutated, IgV genes. The immunohistochemical finding in the tonsil epithelial areas of aggregates of IRTA1+ B cells closely adjacent to plasma cells surrounding small vessels suggests antigen-triggered in situ proliferation/differentiation of memory IRTA1+ cells into plasma cells. Collectively, these results suggest a role of IRTA1 in the immune function of B cells within epithelia. (Blood. 2003;102: 3684-3692

    Achievement of the planetary defense investigations of the Double Asteroid Redirection Test (DART) mission

    Get PDF
    NASA's Double Asteroid Redirection Test (DART) mission was the first to demonstrate asteroid deflection, and the mission's Level 1 requirements guided its planetary defense investigations. Here, we summarize DART's achievement of those requirements. On 2022 September 26, the DART spacecraft impacted Dimorphos, the secondary member of the Didymos near-Earth asteroid binary system, demonstrating an autonomously navigated kinetic impact into an asteroid with limited prior knowledge for planetary defense. Months of subsequent Earth-based observations showed that the binary orbital period was changed by –33.24 minutes, with two independent analysis methods each reporting a 1σ uncertainty of 1.4 s. Dynamical models determined that the momentum enhancement factor, β, resulting from DART's kinetic impact test is between 2.4 and 4.9, depending on the mass of Dimorphos, which remains the largest source of uncertainty. Over five dozen telescopes across the globe and in space, along with the Light Italian CubeSat for Imaging of Asteroids, have contributed to DART's investigations. These combined investigations have addressed topics related to the ejecta, dynamics, impact event, and properties of both asteroids in the binary system. A year following DART's successful impact into Dimorphos, the mission has achieved its planetary defense requirements, although work to further understand DART's kinetic impact test and the Didymos system will continue. In particular, ESA's Hera mission is planned to perform extensive measurements in 2027 during its rendezvous with the Didymos–Dimorphos system, building on DART to advance our knowledge and continue the ongoing international collaboration for planetary defense

    The Comet Interceptor Mission

    Get PDF
    Here we describe the novel, multi-point Comet Interceptor mission. It is dedicated to the exploration of a little-processed long-period comet, possibly entering the inner Solar System for the first time, or to encounter an interstellar object originating at another star. The objectives of the mission are to address the following questions: What are the surface composition, shape, morphology, and structure of the target object? What is the composition of the gas and dust in the coma, its connection to the nucleus, and the nature of its interaction with the solar wind? The mission was proposed to the European Space Agency in 2018, and formally adopted by the agency in June 2022, for launch in 2029 together with the Ariel mission. Comet Interceptor will take advantage of the opportunity presented by ESA’s F-Class call for fast, flexible, low-cost missions to which it was proposed. The call required a launch to a halo orbit around the Sun-Earth L2 point. The mission can take advantage of this placement to wait for the discovery of a suitable comet reachable with its minimum ΔV capability of 600 ms−1. Comet Interceptor will be unique in encountering and studying, at a nominal closest approach distance of 1000 km, a comet that represents a near-pristine sample of material from the formation of the Solar System. It will also add a capability that no previous cometary mission has had, which is to deploy two sub-probes – B1, provided by the Japanese space agency, JAXA, and B2 – that will follow different trajectories through the coma. While the main probe passes at a nominal 1000 km distance, probes B1 and B2 will follow different chords through the coma at distances of 850 km and 400 km, respectively. The result will be unique, simultaneous, spatially resolved information of the 3-dimensional properties of the target comet and its interaction with the space environment. We present the mission’s science background leading to these objectives, as well as an overview of the scientific instruments, mission design, and schedule

    Retrospective evaluation of whole exome and genome mutation calls in 746 cancer samples

    No full text
    Funder: NCI U24CA211006Abstract: The Cancer Genome Atlas (TCGA) and International Cancer Genome Consortium (ICGC) curated consensus somatic mutation calls using whole exome sequencing (WES) and whole genome sequencing (WGS), respectively. Here, as part of the ICGC/TCGA Pan-Cancer Analysis of Whole Genomes (PCAWG) Consortium, which aggregated whole genome sequencing data from 2,658 cancers across 38 tumour types, we compare WES and WGS side-by-side from 746 TCGA samples, finding that ~80% of mutations overlap in covered exonic regions. We estimate that low variant allele fraction (VAF < 15%) and clonal heterogeneity contribute up to 68% of private WGS mutations and 71% of private WES mutations. We observe that ~30% of private WGS mutations trace to mutations identified by a single variant caller in WES consensus efforts. WGS captures both ~50% more variation in exonic regions and un-observed mutations in loci with variable GC-content. Together, our analysis highlights technological divergences between two reproducible somatic variant detection efforts

    Evidence of thrust faulting and widespread contraction of Ceres

    No full text
    The surface of the dwarf planet Ceres is considered to be dominated by geological processes typical of small bodies or medium-sized icy bodies, such as impact cratering; there are also features of putative cryovolcanic origin as well as those related to flow of near-surface ice. Extensional features include regional linear troughs, fractures and pit chains, fractures associated with impact craters and with crater floors, and polygonal craters whose walls seem to be structurally controlled. However, no contractional features, which are related to thrust fault activity more typical of large silicate bodies, have been described. Here we report the presence of scarps, ridges and fractures associated with thrust faults, tectonically raised terrains and thrusted craters—all contractional features. These structures closely resemble thrust-fault-related lobate scarps on Mercury and Mars, albeit with lower displacement. They seem more abundant in high-latitude ancient terrains, perhaps owing to illumination effects that aid identification. The observed deformation implies that the crustal material is stronger than water ice but weaker than silicate rocks, consistent with our current knowledge of crustal composition and rheology. These features suggest that large-scale contraction, possibly related to differentiation processes, occurred in the history of Ceres

    Quality of websites of obstetrics and gynecology departments

    No full text
    Background:\bf Background: The internet has become an easily accessible and widely used source of healthcare information. There are, however, no standardized or commonly accepted criteria for the quality of Obstetrics and Gynecology websites. In this study, we aimed to evaluate the quality of websites of Obstetrics and Gynecology departments in German-speaking countries and to compare websites nationally and internationally. Methods:\bf Methods: We scored 672 websites from Germany (n = 566), Austria (n = 57), and Switzerland (n = 49) using the objective criteria: Google search rank (2 items), technical aspects (11 items), navigation (8 items), and content (6 items) for a 26 point score. Scores were compared nationally and inter nationally. Multivariable regression models assessed good quality scores (\geq50% of maximum) as the dependent variables and country, academic affiliation, being member of a healthcare consortium, confessional affiliation, and content management system (CMS) use as independent variables. Results:\bf Results: The mean score of websites was 13.8 ±\pm 3.3. 4.2% were rated as good (\geq75% of maximum), 61.8% as fair ((\geq50% of maximum). German (14.0 ±\pm 3.2) and Swiss (13.8 ±\pm 4.0) websites scored significantly higher compared to Austrian websites (11.6 ±\pm 2.5) (P < 0.001 and P = 0.005, respectively). Within Germany, academic had higher scores than non-academic departments (14.9 ±\pm 3.2 vs. 13.7 ±\pm 3.1, P < 0.001). Single institutions had higher scores compared to healthcare consortium institutions (14.1 ±\pm 3.2 vs. 13.2 ±\pm 2.6, P = 0.003). Departments in Northern and Southern states had higher scores compared to Eastern states (14.4 ±\pm 3.2 and 14.2 ±\pm 3.2 vs. 13.0 ±\pm 3.0, P < 0.001). In multivariate regression models, all subscores (all: P < 0.001) independently predicted a website’s reaching a good quality score, with navigation subscore as strongest predictor. Affiliations were predictors for some good individual subscores, but not for others. High content subscore was associated with good Google search rank, technical aspects, and navigation subscores. Conclusions:\bf Conclusions: The quality of websites of Obstetrics and Gynecology departments varies widely. We found marked differences depending on country, affiliation, and region
    corecore