1,573 research outputs found

    Dynamic Environmental Photosynthetic Imaging Reveals Emergent Phenotypes.

    Full text link
    Understanding and improving the productivity and robustness of plant photosynthesis requires high-throughput phenotyping under environmental conditions that are relevant to the field. Here we demonstrate the dynamic environmental photosynthesis imager (DEPI), an experimental platform for integrated, continuous, and high-throughput measurements of photosynthetic parameters during plant growth under reproducible yet dynamic environmental conditions. Using parallel imagers obviates the need to move plants or sensors, reducing artifacts and allowing simultaneous measurement on large numbers of plants. As a result, DEPI can reveal phenotypes that are not evident under standard laboratory conditions but emerge under progressively more dynamic illumination. We show examples in mutants of Arabidopsis of such "emergent phenotypes" that are highly transient and heterogeneous, appearing in different leaves under different conditions and depending in complex ways on both environmental conditions and plant developmental age. These emergent phenotypes appear to be caused by a range of phenomena, suggesting that such previously unseen processes are critical for plant responses to dynamic environments

    Measuring Polarization with DASI

    Full text link
    We describe an experiment to measure the polarization of the Cosmic Microwave Background (CMB) with the Degree Angular Scale Interferometer (DASI), a compact microwave interferometer optimized to detect CMB anisotropy at multipoles 140 to 900. The telescope has operated at the Amundsen-Scott South Pole research station since 2000 January. The telescope was retrofit as a polarimeter during the 2000--2001 austral summer, and throughout the 2001 and 2002 austral winters has made observations of the CMB with sensitivity to all four Stokes parameters. The telescope performance has been extensively characterized through observations of artificial sources, the Moon, and polarized and unpolarized Galactic sources. In 271 days of observation, DASI has differenced the CMB fluctuations in two fields to an rms noise level of 2.8 uK.Comment: 12 pages, 9 figures, submitted to the Astrophysical Journa

    Mass Spectrometry-Based (GeLC-MS/MS) Comparative Proteomic Analysis of Endoscopically (ePFT) Collected Pancreatic and Gastroduodenal Fluids

    Get PDF
    Objectives: The secretin-stimulated endoscopic pancreatic function test (ePFT) allows for the safe collection of gastroduodenal and pancreatic fluid from the duodenum. We test the hypothesis that these endoscopically collected fluids have different proteomes. As such, we aim to show that the ePFT method can be used to collect fluid enriched in pancreatic proteins to test for pancreatic function. Methods: Gastroduodenal and pancreatic fluid were collected sequentially from chronic pancreatitis patients undergoing an ePFT. Proteins from each fluid type were extracted using previously published optimized methods and subjected to GeLC-MS/MS analysis for protein identification and bioinformatics analysis. Results: Mass spectrometry analysis identified proteins that were exclusive in either gastroduodenal (46) or pancreatic fluid (234). Subsequent quantitative analysis revealed proteins that were differentially abundant with statistical significance. As expected, proteolytic enzymes and protease inhibitors were among the differentially detected proteins. The proteases pepsinogens and gastrin were enriched in gastroduodenal fluid, while common pancreatic enzymes (e.g., aminopeptidase N, chymotrypsin C, elastase-3A, trypsin, and carboxypeptidase A1, and elastase 2B) were found in greater abundance in pancreatic fluid. Similarly for protease inhibitors, members of the cystatin family were exclusive to gastroduodenal fluid, while serpins A11, B4, and D1 were exclusive to pancreatic fluid. Conclusions: We have shown that ePFT collection coupled with mass spectrometry can be used to identify differentially detected proteins in gastroduodenal and pancreatic fluids. The data obtained using GeLC-MS/MS techniques provide further evidence supporting the feasibility of using ePFT-collected fluid to study specific diseases of the upper gastrointestinal tract, such as chronic pancreatitis

    Treatment of established postoperative nausea and vomiting: a quantitative systematic review

    Get PDF
    BACKGROUND: The relative efficacy of antiemetics for the treatment of postoperative nausea and vomiting (PONV) is poorly understood. METHODS: Systematic search (MEDLINE, Embase, Cochrane Library, bibliographies, any language, to 8.2000) for randomised comparisons of antiemetics with any comparator for the treatment of established PONV. Dichotomous data on prevention of further nausea and vomiting, and on side effects were combined using a fixed effect model. RESULTS: In seven trials (1,267 patients), 11 different antiemetics were tested without placebos; these data were not further analysed. Eighteen trials (3,809) had placebo controls. Dolasetron 12.5–100 mg, granisetron 0.1–3 mg, tropisetron 0.5–5 mg, and ondansetron 1–8 mg prevented further vomiting with little evidence of dose-responsiveness; with all regimens, absolute risk reductions compared with placebo were 20%–30%. The anti-nausea effect was less pronounced. Headache was dose-dependent. Results on propofol were contradictory. The NK(1) antagonist GR205171, isopropyl alcohol vapor, metoclopramide, domperidone, and midazolam were tested in one trial each with a limited number of patients. CONCLUSIONS: Of 100 vomiting surgical patients receiving a 5-HT(3) receptor antagonist, 20 to 30 will stop vomiting who would not have done so had they received a placebo; less will profit from the anti-nausea effect. There is a lack of evidence for a clinically relevant dose-response; minimal effective doses may be used. There is a discrepancy between the plethora of trials on prevention of PONV and the paucity of trials on treatment of established symptoms. Valid data on the therapeutic efficacy of classic antiemetics, which have been used for decades, are needed

    Aggregated a-synuclein and complex I deficiency: exploration of their relationship in differentiated neurons

    Get PDF
    α-Synuclein becomes misfolded and aggregated upon damage by various factors, for example, by reactive oxygen species. These aggregated forms have been proposed to have differential toxicities and their interaction with mitochondria may cause dysfunction within this organelle that contributes to the pathogenesis of Parkinson’s disease (PD). In particular, the association of α-synuclein with mitochondria occurs through interaction with mitochondrial complex I and importantly defects of this protein have been linked to the pathogenesis of PD. Therefore, we investigated the relationship between aggregated α-synuclein and mitochondrial dysfunction, and the consequences of this interaction on cell survival. To do this, we studied the effects of α-synuclein on cybrid cell lines harbouring mutations in either mitochondrial complex I or IV. We found that aggregated α-synuclein inhibited mitochondrial complex I in control and complex IV-deficient cells. However, when aggregated α-synuclein was applied to complex I-deficient cells, there was no additional inhibition of mitochondrial function or increase in cell death. This would suggest that as complex I-deficient cells have already adapted to their mitochondrial defect, the subsequent toxic effects of α-synuclein are reduced

    The effect of crystalloid versus medium molecular weight colloid solution on post-operative nausea and vomiting after ambulatory gynecological surgery - a prospective randomized trial.

    Get PDF
    UNLABELLED: ABSTRACT: BACKGROUND: Intravenous fluid is recommended in international guidelines to improve patient post-operative symptoms, particularly nausea and vomiting. The optimum fluid regimen has not been established. This prospective, randomized, blinded study was designed to determine if administration of equivolumes of a colloid (hydroxyethyl starch 130/0.4) reduced post operative nausea and vomiting in healthy volunteers undergoing ambulatory gynecologic laparoscopy surgery compared to a crystalloid solution (Hartmann\u27s Solution). METHODS: 120 patients were randomized to receive intravenous colloid (N = 60) or crystalloid (N = 60) intra-operatively. The volume of fluid administered was calculated at 1.5 ml.kg-1 per hour of fasting. Patients were interviewed to assess nausea, vomiting, anti-emetic use, dizziness, sore throat, headache and subjective general well being at 30 minutes and 2, 24 and 48 hours post operatively. Pulmonary function testing was performed on a subgroup. RESULTS: At 2 hours the proportion of patients experiencing nausea (38.2 % vs 17.9%, P = 0.03) and the mean nausea score were increased in the colloid compared to crystalloid group respectively (1.49 ± 0.3 vs 0.68 ± 0.2, P = 0.028). The incidence of vomiting and anti-emetic usage was low and did not differ between the groups. Sore throat, dizziness, headache and general well being were not different between the groups. A comparable reduction on post-operative FVC and FEV-1 and PEFR was observed in both groups. CONCLUSIONS: Intra-operative administration of colloid increased the incidence of early postoperative nausea and has no advantage over crystalloid for symptom control after gynaecological laparoscopic surgery

    Signalling plasticity and energy saving in a tropical bushcricket

    Get PDF
    Males of the tropical bushcricket Mecopoda elongata synchronize their acoustic advertisement signals (chirps) in interactions with other males. However, synchrony is not perfect and distinct leader and follower roles are often maintained. In entrainment experiments in which conspecific signals were presented at various rates, chirps displayed as follower showed notable signal plasticity. Follower chirps were shortened by reducing the number and duration of syllables, especially those of low and medium amplitude. The degree of shortening depended on the time delay between leader and follower signals and the sound level of the entraining stimulus. The same signal plasticity was evident in male duets, with the effect that the last syllables of highest amplitude overlapped more strongly. Respiratory measurements showed that solo singing males producing higher chirp rates suffered from higher metabolic costs compared to males singing at lower rates. In contrast, respiratory rate was rather constant during a synchronous entrainment to a conspecific signal repeated at various rates. This allowed males to maintain a steady duty cycle, associated with a constant metabolic rate. Results are discussed with respect to the preference for leader signals in females and the possible benefits males may gain by overlapping their follower signals in a chorus

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Azimuthal anisotropy of charged particles at high transverse momenta in PbPb collisions at sqrt(s[NN]) = 2.76 TeV

    Get PDF
    The azimuthal anisotropy of charged particles in PbPb collisions at nucleon-nucleon center-of-mass energy of 2.76 TeV is measured with the CMS detector at the LHC over an extended transverse momentum (pt) range up to approximately 60 GeV. The data cover both the low-pt region associated with hydrodynamic flow phenomena and the high-pt region where the anisotropies may reflect the path-length dependence of parton energy loss in the created medium. The anisotropy parameter (v2) of the particles is extracted by correlating charged tracks with respect to the event-plane reconstructed by using the energy deposited in forward-angle calorimeters. For the six bins of collision centrality studied, spanning the range of 0-60% most-central events, the observed v2 values are found to first increase with pt, reaching a maximum around pt = 3 GeV, and then to gradually decrease to almost zero, with the decline persisting up to at least pt = 40 GeV over the full centrality range measured.Comment: Replaced with published version. Added journal reference and DO
    • …
    corecore