85 research outputs found

    Electrochemical Behavior and Determination of Rutin on Modified Carbon Paste Electrodes

    Get PDF
    The performances of ionic liquid (1-hexyl-3-methylimidazolium-bis(trifluoromethylsulfonyl)imide, IL/CPE) and iron phthalocyanine (IP/CPE) modified carbon paste electrodes in electroanalytical determinations of rutin were evaluated and compared to the performance of unmodified carbon paste electrode (CPE). Cyclic voltammetry (CV), differential pulse voltammetry (DPV), differential pulse adsorptive stripping voltammetry (DPAdSV), and amperometry were used for rutin analysis. The best current responses of rutin were obtained at pH 4.0 for all tested techniques. IL/CPE electrode was found to perform best with DPAdSV technique, where a detection limit (LOD) as low as 5 nmol L−1 of rutin was found. On the other hand, IP/CPE showed itself to be an optimum choice for DPV technique, where LOD of 80 nmol L−1 was obtained. Analytical applicability of newly prepared electrodes was demonstrated on determination of rutin in the model samples and the extracts of buckwheat seeds. To find an optimum method for buckwheat seeds extraction, a boiling water extraction (BWE), Soxhlet extraction (SE), pressurized solvent extraction (PSE), and supercritical fluid extraction (SFE) were tested

    Electrochemically Pretreated Carbon Microfiber Electrodes as Sensitive HPLC-EC Detectors

    Get PDF
    The paper focuses on the analysis and detection of electroactive compounds using high-performance liquid chromatography (HPLC) combined with electrochemical detection (EC). The fabrication and utilization of electrochemically treated carbon fiber microelectrodes (CFMs) as highly sensitive amperometric detectors in HPLC are described. The applied pretreatment procedure is beneficial for analytical characteristics of the sensor as demonstrated by analysis of the model set of phenolic acids. The combination of CFM with separation power of HPLC technique allows for improved detection limits due to unique electrochemical properties of carbon fibers. The CFM proved to be a promising tool for amperometric detection in liquid chromatography

    Regulated Electric Drainage and its Interference with Track Circuits

    Get PDF
    Electric drainage is a power electronic device used to protect underground metal devices (such as piping) from the corrosive effects of stray currents. Stray currents are usually caused by DC electric traction, such as trams or railways. In places where stray currents leave the underground device and return into rails, they cause significant electrochemical corrosion of buried devices. The principle of electric drainage is based on electrical connection between the underground device and electric traction rails, which ensures that current flows through this connection, instead of flowing into the ground. Nowadays, the most widely used type is regulated electric drainage, where current is regulated by means of Pulse Width Modulation (PWM). Because of this modulation, current flowing through the drainage contains harmonic components with different frequencies. In modern railways, track circuits are often used as an important part of the track security system. For safe operation, it is necessary to ensure that frequencies generated by the drainage do not interfere with track circuits. This paper describes the design of a regulated drainage control system, with regard to its compatibility with track circuits and this paper contains related computer simulations and discussion of the result

    The Use of the Imperialist Competitive Algorithm in Optimising the Setting of the Tram Speed Controller in the Development of a Matlab-Simulink Environment

    Get PDF
    Estimating the electric power used by railway vehicles is an important factor in the planning of future power consumption, looking for possibilities to reduce the use of electric power and therefore also reduce carbon emissions. To improve the estimation, we used the imperialist competitive algorithm in the optimisation process of a mathematical model of a tram vehicle. Specifically, in the setting of the proportional and summation constant of the vehicle speed controller which emulates the activity of the driver in the simulation. Our work presents a new approach to optimising the estimation of energy consumption in tram transport. The method used is based on mathematical modelling and simulation of social development in human society. To obtain the input data for the simulation, we performed a measurement of the reference speed by means of a GPS receiver located in a sample tram vehicle. Subsequently, to verify the model and energy calculation results, we measured the output currents and voltage from the traction converter station at the corresponding time. Our method achieved a 93 % match between the measured and simulated power consumption

    Dimeric cyanobacterial cyclopent-4-ene-1,3-dione as selective inhibitor of Gram-positive bacteria growth: Bio-production approach and preparative isolation by HPCCC

    Get PDF
    The need for new antimicrobial agents is greater than ever because of the emergence of multidrug resistance in common pathogens and incidence of new infections. Cyclopent-4-ene-1,3-diones (CPDs) have been reported as a new class of compounds with promising antimicrobial and antifungal properties. Herein we report the selective antibiotic properties of nostotrebin 6, a phenolic CPD produced biotechnologically by the culture of cyanobacterium Nostoc sp. str. LukeĆĄovĂĄ 27/97. High performance countercurrent chromatography (HPCCC) combined with gel permeation chromatography (GPC) was used for the isolation of nostotrebin 6 with a relatively high 0.53 ± 0.1% yield (calculated from dried biomass) and final purity higher than 96%. Nostotrebin 6 was tested for its antimicrobial and antifungal activities by using standard micro-dilution method, and the results were expressed as minimal inhibitory concentrations (MICs). Nostotrebin 6 unequivocally inhibited the growth of Gram-positive reference (Enterococcus faecalis CCM 4224, Staphylococcus aureus CCM 4223 and Staphylococcus aureus CCM 3953) and multidrug-resistant (Staphylococcus haemolyticus A/16568, Staphylococcus aureus MRSA 4591 and Enterococcus faecium VanA 419/ana) strains. Its strongest effect was exerted against the Gram-positive bacteria with MICs ranging between 6.25 and 15.6 ÎŒg/mL. There was no effect on Gram-negative strains tested and yeasts. Our results suggest that nostotrebin 6 could serve as basic nucleus for further design of novel antibiotic agents and demonstrate that the bio-production approach based on HPCCC/GPC isolation endpoint is an efficient methodology for obtaining nostotrebin 6 in multi-gram scale. Furthermore, the presented isolation method can be easily up-scaled to process kilograms of the cyanobacterial biomass.This work was supported by the Palacky University Internal Financial Support, project no. IGA_LF_2016_012 (J.V.) and IGA_LF_2016_022 (M.K.), by the project ALGAIN (CZ.1.07/2.3.00/30.0059, J.C.), by the Center for Algal Biotechnology-ALGATECH (CZ. 1.05/21.00/03.0110, J.C., J.K. and P.H.) and by the National Programme of Sustainability I, Ministry of Education Youth and Sports of the Czech Republic, ID: LO1416 (J.C., J.K. and P.H.)

    Magnetic Particle-Based Hybrid Platforms for Bioanalytical Sensors

    Get PDF
    Biomagnetic nano and microparticles platforms have attracted considerable interest in the field of biological sensors due to their interesting physico-chemical properties, high specific surface area, good mechanical stability and opportunities for generating magneto-switchable devices. This review discusses recent advances in the development and characterization of active biomagnetic nanoassemblies, their interaction with biological molecules and their use in bioanalytical sensors

    Status Update and Interim Results from the Asymptomatic Carotid Surgery Trial-2 (ACST-2)

    Get PDF
    Objectives: ACST-2 is currently the largest trial ever conducted to compare carotid artery stenting (CAS) with carotid endarterectomy (CEA) in patients with severe asymptomatic carotid stenosis requiring revascularization. Methods: Patients are entered into ACST-2 when revascularization is felt to be clearly indicated, when CEA and CAS are both possible, but where there is substantial uncertainty as to which is most appropriate. Trial surgeons and interventionalists are expected to use their usual techniques and CE-approved devices. We report baseline characteristics and blinded combined interim results for 30-day mortality and major morbidity for 986 patients in the ongoing trial up to September 2012. Results: A total of 986 patients (687 men, 299 women), mean age 68.7 years (SD ± 8.1) were randomized equally to CEA or CAS. Most (96%) had ipsilateral stenosis of 70-99% (median 80%) with contralateral stenoses of 50-99% in 30% and contralateral occlusion in 8%. Patients were on appropriate medical treatment. For 691 patients undergoing intervention with at least 1-month follow-up and Rankin scoring at 6 months for any stroke, the overall serious cardiovascular event rate of periprocedural (within 30 days) disabling stroke, fatal myocardial infarction, and death at 30 days was 1.0%. Conclusions: Early ACST-2 results suggest contemporary carotid intervention for asymptomatic stenosis has a low risk of serious morbidity and mortality, on par with other recent trials. The trial continues to recruit, to monitor periprocedural events and all types of stroke, aiming to randomize up to 5,000 patients to determine any differential outcomes between interventions. Clinical trial: ISRCTN21144362. © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved

    Second asymptomatic carotid surgery trial (ACST-2): a randomised comparison of carotid artery stenting versus carotid endarterectomy

    Get PDF
    Background: Among asymptomatic patients with severe carotid artery stenosis but no recent stroke or transient cerebral ischaemia, either carotid artery stenting (CAS) or carotid endarterectomy (CEA) can restore patency and reduce long-term stroke risks. However, from recent national registry data, each option causes about 1% procedural risk of disabling stroke or death. Comparison of their long-term protective effects requires large-scale randomised evidence. Methods: ACST-2 is an international multicentre randomised trial of CAS versus CEA among asymptomatic patients with severe stenosis thought to require intervention, interpreted with all other relevant trials. Patients were eligible if they had severe unilateral or bilateral carotid artery stenosis and both doctor and patient agreed that a carotid procedure should be undertaken, but they were substantially uncertain which one to choose. Patients were randomly allocated to CAS or CEA and followed up at 1 month and then annually, for a mean 5 years. Procedural events were those within 30 days of the intervention. Intention-to-treat analyses are provided. Analyses including procedural hazards use tabular methods. Analyses and meta-analyses of non-procedural strokes use Kaplan-Meier and log-rank methods. The trial is registered with the ISRCTN registry, ISRCTN21144362. Findings: Between Jan 15, 2008, and Dec 31, 2020, 3625 patients in 130 centres were randomly allocated, 1811 to CAS and 1814 to CEA, with good compliance, good medical therapy and a mean 5 years of follow-up. Overall, 1% had disabling stroke or death procedurally (15 allocated to CAS and 18 to CEA) and 2% had non-disabling procedural stroke (48 allocated to CAS and 29 to CEA). Kaplan-Meier estimates of 5-year non-procedural stroke were 2·5% in each group for fatal or disabling stroke, and 5·3% with CAS versus 4·5% with CEA for any stroke (rate ratio [RR] 1·16, 95% CI 0·86–1·57; p=0·33). Combining RRs for any non-procedural stroke in all CAS versus CEA trials, the RR was similar in symptomatic and asymptomatic patients (overall RR 1·11, 95% CI 0·91–1·32; p=0·21). Interpretation: Serious complications are similarly uncommon after competent CAS and CEA, and the long-term effects of these two carotid artery procedures on fatal or disabling stroke are comparable. Funding: UK Medical Research Council and Health Technology Assessment Programme

    eL-Chem Viewer: A Freeware Package for the Analysis of Electroanalytical Data and Their Post-Acquisition Processing

    No full text
    In electrochemical sensing, a number of voltammetric or amperometric curves are obtained which are subsequently processed, typically by evaluating peak currents and peak potentials or wave heights and half-wave potentials, frequently after background correction. Transformations of voltammetric data can help to extract specific information, e.g., the number of transferred electrons, and can reveal aspects of the studied electrochemical system, e.g., the contribution of adsorption phenomena. In this communication, we introduce a LabView-based software package, ‘eL-Chem Viewer’, which is for the analysis of voltammetric and amperometric data, and enables their post-acquisition processing using semiderivative, semiintegral, derivative, integral and elimination procedures. The software supports the single-click transfer of peak/wave current and potential data to spreadsheet software, a feature that greatly improves productivity when constructing calibration curves, trumpet plots and performing similar tasks. eL-Chem Viewer is freeware and can be downloaded from www.lchem.cz/elchemviewer.htm

    Endoscopic Third Ventriculostomy in Previously Shunted Children

    Get PDF
    Endoscopic third ventriculostomy (ETV) is a routine and safe procedure for therapy of obstructive hydrocephalus. The aim of our study is to evaluate ETV success rate in therapy of obstructive hydrocephalus in pediatric patients formerly treated by ventriculoperitoneal (V-P) shunt implantation. From 2001 till 2011, ETV was performed in 42 patients with former V-P drainage implantation. In all patients, the obstruction in aqueduct or outflow parts of the fourth ventricle was proved by MRI. During the surgery, V-P shunt was clipped and ETV was performed. In case of favourable clinical state and MRI functional stoma, the V-P shunt has been removed 3 months after ETV. These patients with V-P shunt possible removing were evaluated as successful. In our group of 42 patients we were successful in 29 patients (69%). There were two serious complications (4.7%)—one patient died 2.5 years and one patient died 1 year after surgery in consequence of delayed ETV failure. ETV is the method of choice in obstructive hydrocephalus even in patients with former V-P shunt implantation. In case of acute or scheduled V-P shunt surgical revision, MRI is feasible, and if ventricular system obstruction is diagnosed, the hydrocephalus may be solved endoscopically
    • 

    corecore