26 research outputs found

    Touch and Hearing Mediate Osseoperception

    Get PDF
    Osseoperception is the sensation arising from the mechanical stimulation of a bone-anchored prosthesis. Here we show that not only touch, but also hearing is involved in this phenomenon. Using mechanical vibrations ranging from 0.1 to 6 kHz, we performed four psychophysical measures (perception threshold, sensation discrimination, frequency discrimination and reaction time) on 12 upper and lower limb amputees and found that subjects: consistently reported perceiving a sound when the stimulus was delivered at frequencies equal to or above 400 Hz; were able to discriminate frequency differences between stimuli delivered at high stimulation frequencies (∼1500 Hz); improved their reaction time for bimodal stimuli (i.e. when both vibration and sound were perceived). Our results demonstrate that osseoperception is a multisensory perception, which can explain the improved environment perception of bone-anchored prosthesis users. This phenomenon might be exploited in novel prosthetic devices to enhance their control, thus ultimately improving the amputees' quality of life

    Consensus Statement on Bone Conduction Devices and Active Middle Ear Implants in Conductive and Mixed Hearing Loss

    Get PDF
    Nowadays, several options are available to treat patients with conductive or mixed hearing loss. Whenever surgical intervention is not possible or contra-indicated, and amplification by a conventional hearing device (e.g., behind-the-ear device) is not feasible, then implantable hearing devices are an indispensable next option. Implantable bone-conduction devices and middle-ear implants have advantages but also limitations concerning complexity/invasiveness of the surgery, medical complications, and effectiveness. To counsel the patient, the clinician should have a good overview of the options with regard to safety and reliability as well as unequivocal technical performance data. The present consensus document is the outcome of an extensive iterative process including ENT specialists, audiologists, health-policy scientists, and representatives/technicians of the main companies in this field. This document should provide a first framework for procedures and technical characterization to enhance effective communication between these stakeholders, improving health care

    Germline variation at 8q24 and prostate cancer risk in men of European ancestry

    Get PDF
    Chromosome 8q24 is a susceptibility locus for multiple cancers, including prostate cancer. Here we combine genetic data across the 8q24 susceptibility region from 71,535 prostate cancer cases and 52,935 controls of European ancestry to define the overall contribution of germline variation at 8q24 to prostate cancer risk. We identify 12 independent risk signals for prostate cancer (p < 4.28 × 10−15), including three risk variants that have yet to be reported. From a polygenic risk score (PRS) model, derived to assess the cumulative effect of risk variants at 8q24, men in the top 1% of the PRS have a 4-fold (95%CI = 3.62–4.40) greater risk compared to the population average. These 12 variants account for ~25% of what can be currently explained of the familial risk of prostate cancer by known genetic risk factors. These findings highlight the overwhelming contribution of germline variation at 8q24 on prostate cancer risk which has implications for population risk stratification

    Fine-mapping of prostate cancer susceptibility loci in a large meta-analysis identifies candidate causal variants

    Get PDF
    Prostate cancer is a polygenic disease with a large heritable component. A number of common, low-penetrance prostate cancer risk loci have been identified through GWAS. Here we apply the Bayesian multivariate variable selection algorithm JAM to fine-map 84 prostate cancer susceptibility loci, using summary data from a large European ancestry meta-analysis. We observe evidence for multiple independent signals at 12 regions and 99 risk signals overall. Only 15 original GWAS tag SNPs remain among the catalogue of candidate variants identified; the remainder are replaced by more likely candidates. Biological annotation of our credible set of variants indicates significant enrichment within promoter and enhancer elements, and transcription factor-binding sites, including AR, ERG and FOXA1. In 40 regions at least one variant is colocalised with an eQTL in prostate cancer tissue. The refined set of candidate variants substantially increase the proportion of familial relative risk explained by these known susceptibility regions, which highlights the importance of fine-mapping studies and has implications for clinical risk profiling. © 2018 The Author(s).Prostate cancer is a polygenic disease with a large heritable component. A number of common, low-penetrance prostate cancer risk loci have been identified through GWAS. Here we apply the Bayesian multivariate variable selection algorithm JAM to fine-map 84 prostate cancer susceptibility loci, using summary data from a large European ancestry meta-analysis. We observe evidence for multiple independent signals at 12 regions and 99 risk signals overall. Only 15 original GWAS tag SNPs remain among the catalogue of candidate variants identified; the remainder are replaced by more likely candidates. Biological annotation of our credible set of variants indicates significant enrichment within promoter and enhancer elements, and transcription factor-binding sites, including AR, ERG and FOXA1. In 40 regions at least one variant is colocalised with an eQTL in prostate cancer tissue. The refined set of candidate variants substantially increase the proportion of familial relative risk explained by these known susceptibility regions, which highlights the importance of fine-mapping studies and has implications for clinical risk profiling. © 2018 The Author(s).Peer reviewe

    A novel bone conduction implant (BCI): Engineering aspects and pre-clinical studies

    No full text
    Percutaneous bone anchored hearing aids (BAHA) are today an important rehabilitation alternative for patients suffering from conductive or mixed hearing loss. Despite their success they are associated with drawbacks such as skin infections, accidental or spontaneous loss of the bone implant, and patient refusal for treatment due to stigma. A novel bone conduction implant (BCI) system has been proposed as an alternative to the BAHA system because it leaves the skin intact. Such a BCI system has now been developed and the encapsulated transducer uses a non-screw attachment to a hollow recess of the lateral portion of the temporal bone. The aim of this study is to describe the basic engineering principals and some preclinical results obtained with the new BCI system. Laser Doppler vibrometer measurements on three cadaver heads show that the new BCI system produces 0-10 dB higher maximum output acceleration level at the ipsilateral promontory relative to conventional ear-level BAHA at speech frequencies. At the contralateral promontory the maximum output acceleration level was considerably lower for the BCI than for the BAHA.This is an electronic version of an article published in:Bo Hakansson, Sabine Reinfeldt, Mans Eeg-Olofsson, Per Ostli, Hamidreza Taghavi, Johannes Adler, John Gabrielsson, Stefan Stenfelt and Gosta Granstrom, A novel bone conduction implant (BCI): Engineering aspects and pre-clinical studies, 2010, INTERNATIONAL JOURNAL OF AUDIOLOGY, (49), 3, 203-215.INTERNATIONAL JOURNAL OF AUDIOLOGY is available online at informaworldTM: http://dx.doi.org/10.3109/14992020903264462Copyright: Taylor & Francishttp://www.tandf.co.uk/journals/default.as

    Nitinol versus steel partially covered self-expandable metal stent for malignant distal biliary obstruction: a randomized trial.

    No full text
    Covered nitinol alloy self-expandable metal stents (SEMSs) have been developed to overcome the shortcomings of steel SEMS in patients with malignant biliary obstruction. In a randomized, multicenter trial, we compared stent patency, patient survival, and adverse events in patients with partly covered stents made from steel or nitinol

    Real-time PCR-assay in the delivery suite for determination of group B streptococcal colonization in a setting with risk-based antibiotic prophylaxis

    No full text
    Objective: Intrapartum antibiotic prophylaxis (IAP) reduces the incidence of neonatal early onset group B streptococcal infections. The present study investigated if an automated PCR-assay, used bedside by the labor ward personnel was manageable and could decrease the use of IAP in a setting with a risk-based IAP strategy. Methods: The study comprises two phases. Phase 1 was a multicenter, randomized, controlled trial. Women with selected risk-factors were allocated either to PCR-IAP (prophylaxis given if positive or indeterminate) or IAP. A vaginal/rectal swab and superficial swabs from the neonate for conventional culture were also obtained. Phase 2 was non-randomized, assessing an improved version of the assay. Results: Phase 1 included 112 women in the PCR-IAP group and 117 in the IAP group. Excluding indeterminate results, the assay showed a sensitivity of 89% and a specificity of 90%. In 44 % of the PCR assays the result was indeterminate. The use of IAP was lower in the PCR group (53 versus 92%). Phase 2 included 94 women. The proportion of indeterminate results was reduced (15%). The GBS colonization rate was 31%. Conclusion: The PCR assay, in the hands of labor ward personnel, can be useful for selection of women to which IAP should be offered
    corecore