907 research outputs found

    Rapid testing may not improve uptake of HIV testing and same day results in a rural South African community: a cohort study of 12,000 women

    Get PDF
    <p>Background: Rapid testing of pregnant women aims to increase uptake of HIV testing and results and thus optimize care. We report on the acceptability of HIV counselling and testing, and uptake of results, before and after the introduction of rapid testing in this area.</p> <p>Methods and Principal Findings: HIV counsellors offered counselling and testing to women attending 8 antenatal clinics, prior to enrolment into a study examining infant feeding and postnatal HIV transmission. From August 2001 to April 2003, blood was sent for HIV ELISA testing in line with the Prevention of Mother-to-Child Transmission (PMTCT) programme in the district. From May 2003 to September 2004 women were offered a rapid HIV test as part of the PMTCT programme, but also continued to have ELISA testing for study purposes. Of 12,323 women counselled, 5,879 attended clinic prior to May 2003, and 6,444 after May 2003 when rapid testing was introduced; of whom 4,324 (74.6%) and 4,810 (74.6%) agreed to have an HIV test respectively. Of the 4,810 women who had a rapid HIV test, only 166 (3.4%) requested to receive their results on the same day as testing, the remainder opted to return for results at a later appointment. Women with secondary school education were less likely to agree to testing than those with no education (AOR 0.648, p<0.001), as were women aged 21–35 (AOR 0.762, p<0.001) and >35 years (AOR 0.756, p<0.01) compared to those <20 years.</p> <p>Conclusions: Contrary to other reports, few women who had rapid tests accepted their HIV results the same day. Finding strategies to increase the proportion of pregnant women knowing their HIV results is critical so that appropriate care can be given.</p&gt

    Temperature Dependent Optical and Morphological Properties of Sb2Te3 Thin Films

    Get PDF
    Sb2Te3 thin films of different temperature ranging from room temperature to 200°C were prepared on glass substrate by thermal evaporation method. The effects of temperature on optical and morphological properties of thin films were studied. AFM images indicated crystalline nature of Sb2Te3. The optical properties exhibited a decreasing trend of band gap from 1.24eV to 1.06eV with increase in temperature. Transmittance decreased as the temperature was increased and displayed no transmittance in the visible range at 200°C. Surface roughness decreased up to 150°C after which it increased

    Optimization of thickness of Sb2Te3 thin film as back contact for CdTe thin film solar cells

    Get PDF
    Sb2Te3 thin films of different thickness ranging from 100 to 500 nm were prepd. on glass substrate by thermal evapn. method. The effects of thickness on structural, optical and elec. properties of thin films were studied. XRD revealed that grain size increases from 1.1nm to 98.7 nm with increase in film thickness. The internal strain and dislocation d. decreased with increase in film thickness. The optical band gap decreases from 1.3 to 0.9 eV with increase in film thickness. AFM images indicated cryst. nature of Sb2Te3. Surface roughness increased up to 400nm after which it decreased. The resistivity decreases with increase in thickness at room temp. ranging from 2.9×10-​3 to 1.35×10-​4 Ωcm. The work function and barrier height decreases as the film thickness increases from 5.45 to 5.05eV and barrier height from 0.3 to -​0.1eV. The results elucidate that Sb2Te3 back contact of 400 nm thickness is ideal and efficient to be used in CdTe solar cell

    Synthesis and Characterization of Fe2O3 Nanoparticles Reinforced to Recycled Industrial Aluminium Scrap & Waste Aluminium Beverage Cans for Preparing Metal Matrix Nanocomposites

    Get PDF
    Increased material demand in all sectors is primarily due to exponential growth in population to fulfill human needs and comforts. Recycling of collected aluminium beverage cans and Al 6061 alloy scraps from industries ensures energy savings with reduced environmental problems in fabricating composite parts economically. The iron oxide (α-Fe2O3) nanoparticles were prepared by precipitation method using ferric chloride and ammonia as a precursor. The prepared nanoparticles were characterized by using Transmission Electron Microscope (TEM), X-Ray Diffraction (XRD) and Fourier Transform Infrared (FTIR). Stir cast processing route ensures uniform mix of reinforcement nanoparticles in matrix material. The prepared nanocomposites (matrix: Al Scrap (90% Scrap Al 6061 alloy + 10% Waste Al can); reinforcement: 2%, 4% and 6% wt. of Al matrix) were mechanically characterized for hardness and tensile strengths. It was observed that, increased percent of Fe2O3 nanoparticles in the metal matrix nanocomposite (MMCs) resulted in significant increase in hardness and tensile strength values. Fractography analysis examined viz. scanning electron microscope (SEM) revealed a ductile failure for as-cast Al scrap followed by brittle failure in Al MMC's

    Height and risk of death among men and women: aetiological implications of associations with cardiorespiratory disease and cancer mortality

    Get PDF
    OBJECTIVES: Height is inversely associated with cardiovascular disease mortality risk and has shown variable associations with cancer incidence and mortality. The interpretation of findings from previous studies has been constrained by data limitations. Associations between height and specific causes of death were investigated in a large general population cohort of men and women from the West of Scotland. DESIGN: Prospective observational study. SETTING: Renfrew and Paisley, in the West of Scotland. SUBJECTS: 7052 men and 8354 women aged 45-64 were recruited into a study in Renfrew and Paisley, in the West of Scotland, between 1972 and 1976. Detailed assessments of cardiovascular disease risk factors, morbidity and socioeconomic circumstances were made at baseline. MAIN OUTCOME MEASURES: Deaths during 20 years of follow up classified into specific causes. RESULTS: Over the follow up period 3347 men and 2638 women died. Height is inversely associated with all cause, coronary heart disease, stroke, and respiratory disease mortality among men and women. Adjustment for socioeconomic position and cardiovascular risk factors had little influence on these associations. Height is strongly associated with forced expiratory volume in one second (FEV1) and adjustment for FEV1 considerably attenuated the association between height and cardiorespiratory mortality. Smoking related cancer mortality is not associated with height. The risk of deaths from cancer unrelated to smoking tended to increase with height, particularly for haematopoietic, colorectal and prostate cancers. Stomach cancer mortality was inversely associated with height. Adjustment for socioeconomic position had little influence on these associations. CONCLUSION: Height serves partly as an indicator of socioeconomic circumstances and nutritional status in childhood and this may underlie the inverse associations between height and adulthood cardiorespiratory mortality. Much of the association between height and cardiorespiratory mortality was accounted for by lung function, which is also partly determined by exposures acting in childhood. The inverse association between height and stomach cancer mortality probably reflects Helicobacter pylori infection in childhood resulting inor being associated withshorter height. The positive associations between height and several cancers unrelated to smoking could reflect the influence of calorie intake during childhood on the risk of these cancers

    A human somatostatin receptor (SSTR3), located on chromosome 22, displays preferential affinity for somatostatin-14 like peptides

    Get PDF
    AbstractWe report here on the cloning of a human intronless gene encoding a member of the G-protein linked somatostatin (SST) receptor subfamily, termed SSTR3. Based on the deduced amino acid sequence, this gene encodes a 418 amino acid protein displaying sequence similarity, particularly within putative transmembrane domains, with the recently cloned human SSTR1 (62%), SSTR2 (64%) and SSTR4 (58%) receptors. Membranes prepared from COS-7 cells transiently expressing the human SSTR3 gene bound [125I]Leu8,d-Trp22,-Tyr22 SST-28 in a saturable manner with high affinity (~200 pM) and with rank order of potency (d-Trp8 SST-14 > SST-14 > SMS-201-995 > SST-28) indicative of a somatostatin-14 selective receptor. The pharmacological profile of the expressed human SSTR3 receptor is similar but not identical to that reported for the rat homolog [(1992) J. Biol. Chem. 267,20422] where the peptide selectivity is SST-28 ≧ SST-14 XXX SMS-201-995. Northern blot analysis reveals the presence of an SSTR3 mRNA species of ~5 kb in various regions of the monkey brain, including the frontal cortex, cerebellum, medulla, amygdala, with little or no SSTR3 mRNA detectable in brain regions such as the striatum, hippocampus, and olfactory tubercle. The SSTR3 receptor gene maps to human chromosome 22. The existence of at least four distinct human genes encoding somatostatin-14 selective receptors with diverse pharmacological specificities may help to account for some of the multiple biological actions of somatostatin under normal and pathological conditions

    Measurement of ΜˉΌ\bar{\nu}_{\mu} and ΜΌ\nu_{\mu} charged current inclusive cross sections and their ratio with the T2K off-axis near detector

    Get PDF
    We report a measurement of cross section σ(ΜΌ+nucleus→Ό−+X)\sigma(\nu_{\mu}+{\rm nucleus}\rightarrow\mu^{-}+X) and the first measurements of the cross section σ(ΜˉΌ+nucleus→Ό++X)\sigma(\bar{\nu}_{\mu}+{\rm nucleus}\rightarrow\mu^{+}+X) and their ratio R(σ(Μˉ)σ(Îœ))R(\frac{\sigma(\bar \nu)}{\sigma(\nu)}) at (anti-)neutrino energies below 1.5 GeV. We determine the single momentum bin cross section measurements, averaged over the T2K Μˉ/Îœ\bar{\nu}/\nu-flux, for the detector target material (mainly Carbon, Oxygen, Hydrogen and Copper) with phase space restricted laboratory frame kinematics of ΞΌ\theta_{\mu}500 MeV/c. The results are σ(Μˉ)=(0.900±0.029(stat.)±0.088(syst.))×10−39\sigma(\bar{\nu})=\left( 0.900\pm0.029{\rm (stat.)}\pm0.088{\rm (syst.)}\right)\times10^{-39} and $\sigma(\nu)=\left( 2.41\ \pm0.022{\rm{(stat.)}}\pm0.231{\rm (syst.)}\ \right)\times10^{-39}inunitsofcm in units of cm^{2}/nucleonand/nucleon and R\left(\frac{\sigma(\bar{\nu})}{\sigma(\nu)}\right)= 0.373\pm0.012{\rm (stat.)}\pm0.015{\rm (syst.)}$.Comment: 18 pages, 8 figure

    Time-integrated luminosity recorded by the BABAR detector at the PEP-II e+e- collider

    Get PDF
    This article is the Preprint version of the final published artcile which can be accessed at the link below.We describe a measurement of the time-integrated luminosity of the data collected by the BABAR experiment at the PEP-II asymmetric-energy e+e- collider at the ϒ(4S), ϒ(3S), and ϒ(2S) resonances and in a continuum region below each resonance. We measure the time-integrated luminosity by counting e+e-→e+e- and (for the ϒ(4S) only) e+e-→Ό+ÎŒ- candidate events, allowing additional photons in the final state. We use data-corrected simulation to determine the cross-sections and reconstruction efficiencies for these processes, as well as the major backgrounds. Due to the large cross-sections of e+e-→e+e- and e+e-→Ό+ÎŒ-, the statistical uncertainties of the measurement are substantially smaller than the systematic uncertainties. The dominant systematic uncertainties are due to observed differences between data and simulation, as well as uncertainties on the cross-sections. For data collected on the ϒ(3S) and ϒ(2S) resonances, an additional uncertainty arises due to ϒ→e+e-X background. For data collected off the ϒ resonances, we estimate an additional uncertainty due to time dependent efficiency variations, which can affect the short off-resonance runs. The relative uncertainties on the luminosities of the on-resonance (off-resonance) samples are 0.43% (0.43%) for the ϒ(4S), 0.58% (0.72%) for the ϒ(3S), and 0.68% (0.88%) for the ϒ(2S).This work is supported by the US Department of Energy and National Science Foundation, the Natural Sciences and Engineering Research Council (Canada), the Commissariat Ă  l’Energie Atomique and Institut National de Physique NuclĂ©aire et de Physiquedes Particules (France), the Bundesministerium fĂŒr Bildung und Forschung and Deutsche Forschungsgemeinschaft (Germany), the Istituto Nazionale di Fisica Nucleare (Italy), the Foundation for Fundamental Research on Matter (The Netherlands), the Research Council of Norway, the Ministry of Education and Science of the Russian Federation, Ministerio de Ciencia e InnovaciĂłn (Spain), and the Science and Technology Facilities Council (United Kingdom). Individuals have received support from the Marie-Curie IEF program (European Union) and the A.P. Sloan Foundation (USA)

    The beam energy measurement system for the Beijing electron-positron collider

    Full text link
    The beam energy measurement system (BEMS) for the upgraded Beijing electron-positron collider BEPC-II is described. The system is based on measuring the energies of Compton back-scattered photons. The relative systematic uncertainty of the electron and positron beam energy determination is estimated as 2 \cdot 10^{-5}. The relative uncertainty of the beam's energy spread is about 6 %
    • 

    corecore