688 research outputs found
Mortality risk and mental disorders: longitudinal results from the Upper Bavarian Study
The object of the study was the assessment of the mortality risk for persons with a mental disorder in an unselected representative community sample assessed longitudinally. Subjects from a rural area in Upper Bavaria (Germany) participated in semi-structured interviews conducted by research physicians in the 1970s (first assessment) and death-certificate diagnoses were obtained after an interval up to 13 years later. The sample consisted of 1668 community residents aged 15 years and over. Cox regression estimates resulted in an odds ratio of 1·35 (confidence interval 1·01 to 1·81) for persons with a mental disorder classified as marked to very severe. The odds ratio increased with increasing severity of mental illness from 1·04 for mild disorders, 1·30 for marked disorders, to 1·64 for severe or very severe disorders. The relative risk (odds ratio) for persons with a mental disorder only and no somatic disorder was 1·22, for persons with only a somatic disorder 2·00, and for those with both a mental and a somatic disorder 2·13. The presence of somatic illness was responsible for most of the excess mortality. Somatic disorders associated with excess mortality in mental disorders were diseases of the nervous system or sensory organs, diseases of the circulatory system, diseases of the gastrointestinal tract, and diseases of the skeleton, muscles and connective tissue (ICD-8). Thus, while mental illness alone had a limited effect on excess mortality, comorbidity with certain somatic disorders had a significant effec
A linear radiofrequency ion trap for accumulation, bunching, and emittance improvement of radioactive ion beams
An ion beam cooler and buncher has been developed for the manipulation of
radioactive ion beams. The gas-filled linear radiofrequency ion trap system is
installed at the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN. Its
purpose is to accumulate the 60-keV continuous ISOLDE ion beam with high
efficiency and to convert it into low-energy low-emittance ion pulses. The
efficiency was found to exceed 10% in agreement with simulations. A more than
10-fold reduction of the ISOLDE beam emittance can be achieved. The system has
been used successfully for first on-line experiments. Its principle, setup and
performance will be discussed
Low Parental Literacy Is Associated With Worse Asthma Care Measures in Children
To determine if parental literacy is related to emergency department visits, hospitalizations, and days of school missed for children with asthma
Breakdown of the Isobaric Multiplet Mass Equation for the A = 20 and 21 Multiplets
Using the Penning trap mass spectrometer TITAN, we performed the first direct
mass measurements of 20,21Mg, isotopes that are the most proton-rich members of
the A = 20 and A = 21 isospin multiplets. These measurements were possible
through the use of a unique ion-guide laser ion source, a development that
suppressed isobaric contamination by six orders of magnitude. Compared to the
latest atomic mass evaluation, we find that the mass of 21Mg is in good
agreement but that the mass of 20Mg deviates by 3{\sigma}. These measurements
reduce the uncertainties in the masses of 20,21Mg by 15 and 22 times,
respectively, resulting in a significant departure from the expected behavior
of the isobaric multiplet mass equation in both the A = 20 and A = 21
multiplets. This presents a challenge to shell model calculations using either
the isospin non-conserving USDA/B Hamiltonians or isospin non-conserving
interactions based on chiral two- and three-nucleon forces.Comment: 5 pages, 2 figure
Precision mass measurements of magnesium isotopes and implications on the validity of the Isobaric Mass Multiplet Equation
If the mass excess of neutron-deficient nuclei and their neutron-rich mirror
partners are both known, it can be shown that deviations of the Isobaric Mass
Multiplet Equation (IMME) in the form of a cubic term can be probed. Such a
cubic term was probed by using the atomic mass of neutron-rich magnesium
isotopes measured using the TITAN Penning trap and the recently measured
proton-separation energies of Cl and Ar. The atomic mass of
Mg was found to be within 1.6 of the value stated in the Atomic
Mass Evaluation. The atomic masses of Mg were measured to be both
within 1, while being 8 and 34 times more precise, respectively. Using
the Mg mass excess and previous measurements of Cl we uncovered a
cubic coefficient of = 28(7) keV, which is the largest known cubic
coefficient of the IMME. This departure, however, could also be caused by
experimental data with unknown systematic errors. Hence there is a need to
confirm the mass excess of S and the one-neutron separation energy of
Cl, which have both come from a single measurement. Finally, our results
were compared to ab initio calculations from the valence-space in-medium
similarity renormalization group, resulting in a good agreement.Comment: 7 pages, 3 figure
A linear radiofrequency quadrupole ion trap for the cooling and bunching of radioactive ion beams
A linear radiofrequency quadrupole ion guide and beam buncher has been installed at the ISOLTRAP mass spectrometry experiment at the ISOLDE facility at CERN. The apparatus is being used as a beam cooling, accumulation, and bunching system. It operates with a buffer gas that cools the injected ions and converts the quasicontinuous 60- keV beam from the ISOLDE facility to 2.5-keV beam pulses with improved normalized transverse emittance. Recent measurements suggest a capture efficiency of the ion guide of up to 40% and a cooling and bunching efficiency of at least 12% which is expected to still be increased. The improved ISOLTRAP setup has so far been used very successfully in three on-line experiments. (12 refs)
Isotope Shift Measurements of Stable and Short-Lived Lithium Isotopes for Nuclear Charge Radii Determination
Changes in the mean-square nuclear charge radii along the lithium isotopic
chain were determined using a combination of precise isotope shift measurements
and theoretical atomic structure calculations. Nuclear charge radii of light
elements are of high interest due to the appearance of the nuclear halo
phenomenon in this region of the nuclear chart. During the past years we have
developed a new laser spectroscopic approach to determine the charge radii of
lithium isotopes which combines high sensitivity, speed, and accuracy to
measure the extremely small field shift of an 8 ms lifetime isotope with
production rates on the order of only 10,000 atoms/s. The method was applied to
all bound isotopes of lithium including the two-neutron halo isotope Li-11 at
the on-line isotope separators at GSI, Darmstadt, Germany and at TRIUMF,
Vancouver, Canada. We describe the laser spectroscopic method in detail,
present updated and improved values from theory and experiment, and discuss the
results.Comment: 34 pages, 24 figures, 14 table
Vision, mission, and values: From concept to execution at Mayo Clinic
Mayo Clinic displays steadfast commitment to patient care, referral relations, and health care quality through institutional examples of unique, value-add endeavors that are under way with the Mayo Clinic Patient Experience Subcommittee and the Referring Physician Office. In this article, we share the Mayo Model of Care and patient stories that embody the 8 Mayo Clinic values of respect, compassion, integrity, healing, teamwork, excellence, innovation, and stewardship. The Mayo founders imparted to their staff the passion for patient care by encouraging a fair and just culture for its employees. This culture allows the creation, maintenance, and improvement of clinical care, research studies, and educational curricula, which in turn propagate the mission–“To inspire hope and contribute to health and well-being by providing the best care to every patient through integrated clinical practice, education, and research.
Penning-Trap Mass Measurements of the Neutron-Rich K and Ca Isotopes: Resurgence of the N = 28 Shell Strength
We present Penning-trap mass measurements of neutron-rich 44,47-50K and
49,50Ca isotopes carried out at the TITAN facility at TRIUMF-ISAC. The 44K mass
measurement was performed with a charge-bred 4+ ion utilizing the TITAN EBIT,
and agrees with the literature. The mass excesses obtained for 47K and 49,50Ca
are more precise and agree with the values published in the 2003 Atomic Mass
Evaluation (AME'03). The 48,49,50K mass excesses are more precise than the
AME'03 values by more than one order of magnitude. For 48,49K, we find
deviations by 7 sigma and 10 sigma, respectively. The new 49K mass excess
lowers significantly the two-neutron separation energy at the neutron number
N=30 compared with the separation energy calculated from the AME'03 mass-excess
values, and thus, increases the N=28 neutron-shell gap energy at Z=19 by
approximately 1 MeV.Comment: 6 pages, 5 figures, accepted for PR
- …