10 research outputs found

    Small bowel Crohn’s disease: MR enteroclysis and capsule endoscopy compared to balloon-assisted enteroscopy

    Get PDF
    New modalities are available to visualize the small bowel in patients with Crohn’s disease (CD). The aim of this study was to compare the diagnostic yield of magnetic resonance enteroclysis (MRE) and capsule endoscopy (CE) to balloon-assisted enteroscopy (BAE) in patients with suspected or established CD of the small bowel. Consecutive, consenting patients first underwent MRE followed by CE and BAE. Patients with high-grade stenosis at MRE did not undergo CE. Reference standard for small bowel CD activity was a combination of BAE and an expert panel consensus diagnosis. Analysis included 38 patients, 27 (71%) females, mean age 36 (20–74) years, with suspected (n = 20) or established (n = 18) small bowel CD: 16 (42%) were diagnosed with active CD, and 13 (34%) by MRE with suspected high-grade stenosis, who consequently did not undergo CE. The reference standard defined high-grade stenosis in 10 (26%) patients. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value of MRE and CE for small bowel CD activity were 73 and 57%, 90 and 89%, 88 and 67%, and 78 and 84%, respectively. CE was complicated by capsule retention in one patient. MRE has a higher sensitivity and PPV than CE in small bowel CD. The use of CE is considerably limited by the high prevalence of stenotic lesions in these patients

    Transanal endoscopic microsurgery versus endoscopic mucosal resection for large rectal adenomas (TREND-study)

    Get PDF
    Background: Recent non-randomized studies suggest that extended endoscopic mucosal resection (EMR) is equally effective in removing large rectal adenomas as transanal endoscopic microsurgery (TEM). If equally effective, EMR might be a more cost-effective approach as this strategy does not require expensive equipment, general anesthesia and hospital admission. Furthermore, EMR appears to be associated with fewer complications. The aim of this study is to compare the cost-effectiveness and cost-utility of TEM and EMR for the resection of large rectal adenomas. Methods/design. Multicenter randomized trial among 15 hospitals in the Netherlands. Patients with a rectal adenoma 3 cm, located between 115 cm ab ano, will be randomized to a TEM- or EMR-treatment strategy. For TEM, patients will be treated under general anesthesia, adenomas will be dissected en-bloc by a full-thickness excision, and patients will be admitted to the hospital. For EMR, no or conscious sedation is used, lesions will be resected through the submucosal plane i

    Clip placement to prevent delayed bleeding after colonic endoscopic mucosal resection (CLIPPER): study protocol for a randomized controlled trial

    Get PDF
    Background: Endoscopic mucosal resection (EMR) for large colorectal polyps is in most cases the preferred treatment to prevent progression to colorectal carcinoma. The most common complication after EMR is delayed bleeding, occurring in 7% overall and in approximately 10% of polyps ≥ 2 cm in the proximal colon. Previous research has suggested that prophylactic clipping of the mucosal defect after EMR may reduce the incidence of delayed bleeding in polyps with a high bleeding risk. Methods: The CLIPPER trial is a multicenter, parallel-group, single blinded, randomized controlled superiority study. A total of 356 patients undergoing EMR for large (≥ 2 cm) non-pedunculated polyps in the proximal colon will be included and randomized to the clip group or the control group. Prophylactic clipping will be performed in the intervention group to close the resection defect after the EMR with a distance of < 1 cm between the clips. Primary outcome is delayed bleeding within 30 days after EMR. Secondary outcomes are recurrent or residual polyps and clip artifacts during surveillance colonoscopy after 6 months, as well as cost-effectiveness of prophylactic clipping and severity of delayed bleeding. Discussion: The CLIPPER trial is a pragmatic study performed in the Netherlands and is powered to determine the real-time efficacy and cost-effectiveness of prophylactic clipping after EMR of proximal colon polyps ≥ 2 cm in the Netherlands. This study will also generate new data on the achievability of complete closure and the effects of clip placement on scar surveillance after EMR, in order to further promote the debate on the role of prophylactic clipping in everyday clinical practice. Trial registration: ClinicalTrials.gov NCT03309683. Registered on 13 October 2017. Start recruitment: 05 March 2018. Planned completion of recruitment: 31 August 2021

    Clip placement to prevent delayed bleeding after colonic endoscopic mucosal resection (CLIPPER): study protocol for a randomized controlled trial

    Get PDF
    Background: Endoscopic mucosal resection (EMR) for large colorectal polyps is in most cases the preferred treatment to prevent progression to colorectal carcinoma. The most common complication after EMR is delayed bleeding, occurring in 7% overall and in approximately 10% of polyps ≥ 2 cm in the proximal colon. Previous research has suggested that prophylactic clipping of the mucosal defect after EMR may reduce the incidence of delayed bleeding in polyps with a high bleeding risk. Methods: The CLIPPER trial is a multicenter, parallel-group, single blinded, randomized controlled superiority study. A total of 356 patients undergoing EMR for large (≥ 2 cm) non-pedunculated polyps in the proximal colon will be included and randomized to the clip group or the control group. Prophylactic clipping will be performed in the intervention group to close the resection defect after the EMR with a distance of < 1 cm between the clips. Primary outcome is delayed bleeding within 30 days after EMR. Secondary outcomes are recurrent or residual polyps and clip artifacts during surveillance colonoscopy after 6 months, as well as cost-effectiveness of prophylactic clipping and severity of delayed bleeding. Discussion: The CLIPPER trial is a pragmatic study performed in the Netherlands and is powered to determine the real-time efficacy and cost-effectiveness of prophylactic clipping after EMR of proximal colon polyps ≥ 2 cm in the Netherlands. This study will also generate new data on the achievability of complete closure and the effects of clip placement on scar surveillance after EMR, in order to further promote the debate on the role of prophylactic clipping in everyday clinical practice. Trial registration: ClinicalTrials.gov NCT03309683. Registered on 13 October 2017. Start recruitment: 05 March 2018. Planned completion of recruitment: 31 August 2021

    Jejunum abnormalities at MR enteroclysis

    No full text
    Objective: MR enteroclysis has become an important tool to visualize the complete small bowel wall and extramural structures. In many centers, this technique is rapidly becoming the first-line technique for small bowel visualization. MR enteroclysis yields a diagnosis of thickened jejunal loops in some patients. In this paper, we describe an MR enteroclysis protocol and review the literature on jejunum abnormalities with several sample cases. Conclusion: Jejunum abnormalities are not uncommon. These abnormalities can be self-limiting, but some patients suffer from infectious and other pathologic conditions of the small bowel necessitating intervention. (c) 2007 Elsevier Ireland Ltd. All rights reserve

    Endoscopic full-thickness resection (eFTR) of colorectal lesions: results from the Dutch colorectal eFTR registry

    No full text
    Background Endoscopic full-thickness resection (eFTR) is a minimally invasive resection technique that allows definite diagnosis and treatment for complex colorectal lesions Methods Consecutive patients undergoing eFTR in 20 hospitals were prospectively included. The primary outcome was technical success, defined as macroscopic complete en bloc resection. Secondary outcomes were: clinical success, defined as tumor-free resection margins (R0 resection); full-thickness resection rate; and adverse events. Results Between July 2015 and October 2018, 367 procedures were included. Indications were difficult polyps (non-lifting sign and/or difficult location; n = 133), primary resection of suspected T1 colorectal cancer (CRC; n = 71), reresection after incomplete resection of T1 CRC (n = 150), and subepithelial tumors (n = 13). Technical success was achieved in 308 procedures (83.9%). In 21 procedures (5.7 %), eFTR was not performed because the lesion could not be reached or retracted into the cap. In the remaining 346 procedures, R0 resection was achieved in 285 (82.4%) and full-thickness resection in 288 (83.2%). The median diameter of resected specimens was 23mm. Overall adverse event rate was 9.3% (n = 34/367): 10 patients (2.7 %) required emergency surgery for five delayed and two immediate perforations and three cases of appendicitis. Conclusion eFTR is an effective and relatively safe en bloc resection technique for complex colorectal lesions with the potential to avoid surgery. Further studies assessing the role of eFTR in early CRC treatment with long-term outcomes are needed

    Endoscopic full-thickness resection (eFTR) of colorectal lesions:results from the Dutch colorectal eFTR registry

    Get PDF
    Background Endoscopic full-thickness resection (eFTR) is a minimally invasive resection technique that allows definite diagnosis and treatment for complex colorectal lesions Methods Consecutive patients undergoing eFTR in 20 hospitals were prospectively included. The primary outcome was technical success, defined as macroscopic complete en bloc resection. Secondary outcomes were: clinical success, defined as tumor-free resection margins (R0 resection); full-thickness resection rate; and adverse events. Results Between July 2015 and October 2018, 367 procedures were included. Indications were difficult polyps (non-lifting sign and/or difficult location; n = 133), primary resection of suspected T1 colorectal cancer (CRC; n = 71), reresection after incomplete resection of T1 CRC (n = 150), and subepithelial tumors (n = 13). Technical success was achieved in 308 procedures (83.9%). In 21 procedures (5.7 %), eFTR was not performed because the lesion could not be reached or retracted into the cap. In the remaining 346 procedures, R0 resection was achieved in 285 (82.4%) and full-thickness resection in 288 (83.2%). The median diameter of resected specimens was 23mm. Overall adverse event rate was 9.3% (n = 34/367): 10 patients (2.7 %) required emergency surgery for five delayed and two immediate perforations and three cases of appendicitis. Conclusion eFTR is an effective and relatively safe en bloc resection technique for complex colorectal lesions with the potential to avoid surgery. Further studies assessing the role of eFTR in early CRC treatment with long-term outcomes are needed

    Transanal endoscopic microsurgery versus endoscopic mucosal resection for large rectal adenomas (TREND-study)

    No full text
    Abstract Background Recent non-randomized studies suggest that extended endoscopic mucosal resection (EMR) is equally effective in removing large rectal adenomas as transanal endoscopic microsurgery (TEM). If equally effective, EMR might be a more cost-effective approach as this strategy does not require expensive equipment, general anesthesia and hospital admission. Furthermore, EMR appears to be associated with fewer complications. The aim of this study is to compare the cost-effectiveness and cost-utility of TEM and EMR for the resection of large rectal adenomas. Methods/design Multicenter randomized trial among 15 hospitals in the Netherlands. Patients with a rectal adenoma ≥ 3 cm, located between 1–15 cm ab ano, will be randomized to a TEM- or EMR-treatment strategy. For TEM, patients will be treated under general anesthesia, adenomas will be dissected en-bloc by a full-thickness excision, and patients will be admitted to the hospital. For EMR, no or conscious sedation is used, lesions will be resected through the submucosal plane in a piecemeal fashion, and patients will be discharged from the hospital. Residual adenoma that is visible during the first surveillance endoscopy at 3 months will be removed endoscopically in both treatment strategies and is considered as part of the primary treatment. Primary outcome measure is the proportion of patients with recurrence after 3 months. Secondary outcome measures are: 2) number of days not spent in hospital from initial treatment until 2 years afterwards; 3) major and minor morbidity; 4) disease specific and general quality of life; 5) anorectal function; 6) health care utilization and costs. A cost-effectiveness and cost-utility analysis of EMR against TEM for large rectal adenomas will be performed from a societal perspective with respectively the costs per recurrence free patient and the cost per quality adjusted life year as outcome measures. Based on comparable recurrence rates for TEM and EMR of 3.3% and considering an upper-limit of 10% for EMR to be non-inferior (beta-error 0.2 and one-sided alpha-error 0.05), 89 patients are needed per group. Discussion The TREND study is the first randomized trial evaluating whether TEM or EMR is more cost-effective for the treatment of large rectal adenomas. Trial registration number (trialregister.nl) NTR1422</p

    EXCESS workshop: Descriptions of rising low-energy spectra

    No full text
    International audienceMany low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was initiated. In its first iteration in June 2021, ten rare event search collaborations contributed to this initiative via talks and discussions. The contributing collaborations were CONNIE, CRESST, DAMIC, EDELWEISS, MINER, NEWS-G, NUCLEUS, RICOCHET, SENSEI and SuperCDMS. They presented data about their observed energy spectra and known backgrounds together with details about the respective measurements. In this paper, we summarize the presented information and give a comprehensive overview of the similarities and differences between the distinct measurements. The provided data is furthermore publicly available on the workshop’s data repository together with a plotting tool for visualization

    Energy calibration and resolution of the CMS electromagnetic calorimeter in pp collisions at s\sqrt{s} = 7 TeV

    Get PDF
    The energy calibration and resolution of the electromagnetic calorimeter (ECAL) of the CMS detector have been determined using proton-proton collision data from LHC operation in 2010 and 2011 at a centre-of-mass energy of sqrt(s)=7 TeV with integrated luminosities of about 5 inverse femtobarns. Crucial aspects of detector operation, such as the environmental stability, alignment, and synchronization, are presented. The in-situ calibration procedures are discussed in detail and include the maintenance of the calibration in the challenging radiation environment inside the CMS detector. The energy resolution for electrons from Z-boson decays is better than 2% in the central region of the ECAL barrel (for pseudorapidity abs(eta)<0.8) and is 2-5% elsewhere. The derived energy resolution for photons from 125 GeV Higgs boson decays varies across the barrel from 1.1% to 2.6% and from 2.2% to 5% in the entraps. The calibration of the absolute energy is determined from Z to e+e- decays to a precision of 0.4% in the barrel and 0.8% in the endcaps
    corecore