1,378 research outputs found

    Functional and Clinicopathologic Outcomes Using a Modified Vescica Ileale Padovana Technique

    Get PDF
    Objective: To evaluate the clinicopathologic and functional outcomes of a modified Vescica ileale Padovana (VIP) neobladder technique. Methods: Data for 160 patients at a single institution who underwent radical cystectomy and orthotopic VIP neoblad

    Bis(furan-2-ylcarbon­yl) diselenide

    Get PDF
    The title mol­ecule, C10H6O4Se2, lies on a twofold rotation axis. The Se—Se bond length of 2.305 (3) Å is similar to that in diphenyl diselenide [2.3066 (7) and 2.3073 (10) Å for the P and M isomers, respectively] and longer than that in 1,8-diseleno­naph­thalene [2.0879 (8) Å]. The mol­ecule adopts a gauche conformation with respect to the C=O groups

    Verification of the indoor GPS system, by comparison with calibrated coordinates and by angular reference

    Get PDF
    This paper details work carried out to verify the dimensional measurement performance of the Indoor GPS (iGPS) system; a network of Rotary-Laser Automatic Theodolites (R-LATs). Initially tests were carried out to determine the angular uncertainties on an individual R-LAT transmitter-receiver pair. A method is presented of determining the uncertainty of dimensional measurement for a three dimensional coordinate measurement machine. An experimental procedure was developed to compare three dimensional coordinate measurements with calibrated reference points. The reference standard used to calibrate these reference points was a fringe counting interferometer with the multilateration technique employed to establish three dimensional coordinates. This is an extension of the established technique of comparing measured lengths with calibrated lengths. The method was found to be practical and able to establish that the expanded uncertainty of the basic iGPS system was approximately 1 mm at a 95% confidence level. Further tests carried out on a highly optimized version of the iGPS system have shown that the coordinate uncertainty can be reduced to 0.25 mm at a 95% confidence level

    Koetjapic acid chloro­form hemisolvate

    Get PDF
    The asymmetric unit of the title compound, C30H46O4·0.5CHCl3, consists of one koetjapic acid [systematic name: (3R,4aR,4bS,7S,8S,10bS,12aS)-7-(2-carboxy­ethyl)-3,4b,7,10b,12a-penta­methyl-8-(prop-1-en-2-yl)-1,2,3,4,4a,4b,5,6,7,8,9,10,10b,11,12,12a-hexa­deca­hydro­chrysene-3-carboxylic acid] mol­ecule and one half-mol­ecule of chloro­form solvent, which is disordered about a twofold rotation axis. The symmetry-independent component is further disordered over two sites, with occupancies of 0.30 and 0.20. The koetjapic acid contains a fused four-ring system, A/B/C/D. The A/B, B/C and C/D junctions adopt E/trans/cis configurations, respectively. The conformation of ring A is inter­mediate between envelope and half-chair and ring B adopts an envelope conformation whereas rings C and D adopt chair conformations. A weak intra­molecular C—H⋯O hydrogen bond is observed. The koetjapic acid mol­ecules are linked into dimers by two pairs of inter­molecular O—H⋯O hydrogen bonds. The dimers are stacked along the c axis

    Determining initial and follow-up costs of cardiovascular events in a US managed care population

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Cardiovascular (CV) events are prevalent and expensive worldwide both in terms of direct medical costs at the time of the event and follow-up healthcare after the event. This study aims to determine initial and follow-up costs for cardiovascular (CV) events in US managed care enrollees and to compare to healthcare costs for matched patients without CV events.</p> <p>Methods</p> <p>A 5.5-year retrospective matched cohort analysis of claims records for adult enrollees in ~90 US health plans. Patients hospitalized for first CV event were identified from a database containing a representative sample of the commercially-insured US population. The CV-event group (n = 29,688) was matched to a control group with similar demographics but no claims for CV-related events. Endpoints were total direct medical costs for inpatient and outpatient services and pharmacy (paid insurance amount).</p> <p>Results</p> <p>Overall, mean initial inpatient costs were US dollars ()16,981percase(standarddeviation[SD]=) 16,981 per case (standard deviation [SD] = 20,474), ranging from 6,699foratransientischemicattack(meanlengthofstay[LOS]=3.7days)to6,699 for a transient ischemic attack (mean length of stay [LOS] = 3.7 days) to 56,024 for a coronary artery bypass graft (CABG) (mean LOS = 9.2 days). Overall mean health-care cost during 1-year follow-up was 16,582(SD=16,582 (SD = 34,425), an excess of 13,792overthemeancostofmatchedcontrols.ThisdifferenceinaveragecostsbetweenCVeventandmatchedcontrolsubjectswas13,792 over the mean cost of matched controls. This difference in average costs between CV-event and matched-control subjects was 20,862 and 26,014aftertwoandthreeyearsoffollowup.Meanoverallinpatientcostsforsecondeventsweresimilartothoseforfirstevents(26,014 after two and three years of follow-up. Mean overall inpatient costs for second events were similar to those for first events (17,705/case; SD = $22,703). The multivariable regression model adjusting for demographic and clinical characteristics indicated that the presence of a CV event was positively associated with total follow-up costs (P < 0.0001).</p> <p>Conclusions</p> <p>Initial hospitalization and follow-up costs vary widely by type of CV event. The 1-year follow-up costs for CV events were almost as high as the initial hospitalization costs, but much higher for 2- and 3-year follow-up.</p

    Estimation of uncertainty in three-dimensional coordinate measurement by comparison with calibrated points

    Get PDF
    This paper details a method of estimating the uncertainty of dimensional measurement for a three-dimensional coordinate measurement machine. An experimental procedure was developed to compare three-dimensional coordinate measurements with calibrated reference points. The reference standard used to calibrate these reference points was a fringe counting interferometer with a multilateration-like technique employed to establish three-dimensional coordinates. This is an extension of the established technique of comparing measured lengths with calibrated lengths. Specifically a distributed coordinate measurement device was tested which consisted of a network of Rotary-Laser Automatic Theodolites (R-LATs), this system is known commercially as indoor GPS (iGPS). The method was found to be practical and was used to estimate that the uncertainty of measurement for the basic iGPS system is approximately 1 mm at a 95% confidence level throughout a measurement volume of approximately 10 m × 10 m × 1.5 m. © 2010 IOP Publishing Ltd

    Spectral modeling of scintillator for the NEMO-3 and SuperNEMO detectors

    Full text link
    We have constructed a GEANT4-based detailed software model of photon transport in plastic scintillator blocks and have used it to study the NEMO-3 and SuperNEMO calorimeters employed in experiments designed to search for neutrinoless double beta decay. We compare our simulations to measurements using conversion electrons from a calibration source of 207Bi\rm ^{207}Bi and show that the agreement is improved if wavelength-dependent properties of the calorimeter are taken into account. In this article, we briefly describe our modeling approach and results of our studies.Comment: 16 pages, 10 figure

    Teaching open and reproducible scholarship: A critical review of the evidence base for current pedagogical methods and their outcomes

    Get PDF
    In recent years, the scientific community has called for improvements in the credibility, robustness and reproducibility of research, characterized by increased interest and promotion of open and transparent research practices. While progress has been positive, there is a lack of consideration about how this approach can be embedded into undergraduate and postgraduate research training. Specifically, a critical overview of the literature which investigates how integrating open and reproducible science may influence student outcomes is needed. In this paper, we provide the first critical review of the literature surrounding the integration of open and reproducible scholarship into teaching and learning and its associated outcomes in students. Our review highlighted how embedding open and reproducible scholarship appears to be associated with (i) students’ scientific literacies (i.e. students’ understanding of open research, consumption of science, and the development of transferable skills); (ii) student engagement (i.e. motivation and engagement with learning, collaboration, and engagement in open research) and (iii) students’ attitudes towards science (i.e. trust in science and confidence in research findings). However, our review also identified a need for more robust and rigorous methods within pedagogical research, including more interventional and experimental evaluations of teaching practice. We discuss implications for teaching and learning scholarship.info:eu-repo/semantics/publishedVersio

    Exciton dephasing and biexciton binding in CdSe/ZnSe islands

    Get PDF
    The dephasing of excitons and the formation of biexcitons in self-organized CdSe/ZnSe islands grown by molecular-beam epitaxy is investigated using spectrally resolved four-wave mixing. A distribution of exciton-exciton scattering efficiencies and dephasing times in the range of 0.5–10 ps are observed. This indicates the presence of differently localized exciton states at comparable transition energies. Polarization-dependent measurements identify the formation of biexcitons with a biexciton binding energy of more than four times the bulk value. With decreasing exciton energy, the binding energy slightly increases from 21.5 to 23 meV, while its broadening decreases from 5.5 to 3 meV. This is attributed to a strong three-dimensional confinement with improving shape uniformity for decreasing exciton energy

    Study of e+e- --> pi+ pi- pi0 process using initial state radiation with BABAR

    Get PDF
    The process e+e- --> pi+ pi- pi0 gamma has been studied at a center-of-mass energy near the Y(4S) resonance using a 89.3 fb-1 data sample collected with the BaBar detector at the PEP-II collider. From the measured 3pi mass spectrum we have obtained the products of branching fractions for the omega and phi mesons, B(omega --> e+e-)B(omega --> 3pi)=(6.70 +/- 0.06 +/- 0.27)10-5 and B(phi --> e+e-)B(phi --> 3pi)=(4.30 +/- 0.08 +/- 0.21)10-5, and evaluated the e+e- --> pi+ pi- pi0 cross section for the e+e- center-of-mass energy range 1.05 to 3.00 GeV. About 900 e+e- --> J/psi gamma --> pi+ pi- pi0 gamma events have been selected and the branching fraction B(J/psi --> pi+ pi- pi0)=(2.18 +/- 0.19)% has been measured.Comment: 21 pages, 37 postscript figues, submitted to Phys. Rev.
    corecore