1,903 research outputs found
Ground performance of the High-Energy Focusing Telescope (HEFT) attitude control system
The High Energy Focusing Telescope (HEFT) is a balloon-borne, hard x-ray/gamma ray (20-70 keV) astronomical experiment. HEFT's 10 arcminute field of view and 1 arcminute angular resolution place challenging demands on its attitude control system (ACS). A microprocessor-based ACS has been developed to manage target acquisition and sidereal tracking. The ACS consists of a variety of sensors and actuators, with provisions for 2-way ground communication, all controlled by an on-board computer. Ground based pointing performance measurements indicate 1σ jitter of 7" and gyro drift rates of <1" s^(-1). Jitter is expected to worsen in the flight environment, but star tracker data are expected to reduce drift rates significantly, enabling a predicted 1σ absolute attitude determination of ≥4.7". HEFT is scheduled for flight in Spring 2004
Magnetic Resonance Imaging Follow-up of Targeted Biopsy-negative Prostate Lesions
BACKGROUND: The optimal radiological follow-up of prostate lesions negative on magnetic resonance imaging (MRI)-targeted biopsy (MRI-TB) is yet to be optimised. OBJECTIVE: To present medium-term radiological and clinical follow-up of biopsy-negative lesions. DESIGN, SETTING, AND PARTICIPANTS: The records for men who underwent multiparametric MRI at the UCLH one-stop clinic for suspected prostate cancer between September 2017 and March 2020 were reviewed (n = 1199). Patients with Likert 4 or 5 lesions were considered (n = 495), and those with a subsequent negative MRI-TB comprised the final study population (n = 91). OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: Baseline and follow-up MRI and biopsy data (including prostate-specific antigen [PSA], prostate volume, radiological scores, and presence of any noncancerous pathology) were extracted from reports. The last follow-up date was the date of the last test or review in clinic. RESULTS AND LIMITATIONS: Median follow-up was 1.8 yr (656 d, interquartile range [IQR] 359-1008). At baseline, the median age was 65.4 yr (IQR 60.7-70.0), median PSA was 7.1 ng/ml (IQR 4.7-10.0), median prostate volume was 54 ml (IQR 39.5-75.0), and median PSA density (PSAD) was 0.13 ng/ml2 (IQR 0.09-0.18). Eighty-six men (95%) had Likert 4 lesions, while the remaining five (5%) had Likert 5 lesions. Only 21 men (23%) had a single lesion; most had at least two. Atrophy was the most prevalent pathology on MRI-TB, present in 64 men (74%), and followed by acute inflammation in 42 (46%), prostatic intraepithelial neoplasia in 33 (36%), chronic inflammation in 18 (20%), atypia in 13 (14%), and granulomatous inflammation in three (3%). Fifty-eight men had a second MRI study (median 376 d, IQR 361-412). At the second MRI, median PSAD decreased to 0.11 ng/ml2 (IQR 0.08-0.18). A Likert 4 or 5 score persisted only in five men (9%); 40 men (69%) were scored Likert 3, while the remaining 13 (22%) were scored Likert 2 (no lesion). Of 45 men with a Likert ≥3 score, most only had one lesion at the second MRI (28 men; 62%). Of six men with repeat MRI-TB during the study period, two were subsequently diagnosed with prostate cancer and both had persistent Likert 4 scores (at baseline and at least one follow-up MRI). CONCLUSIONS: Most biopsy-negative MRI lesions in the prostate resolve over time, but any persistent lesions should be closely monitored. PATIENT SUMMARY: Lesions in the prostate detected via magnetic resonance imaging (MRI) scans that are negative for cancer on biopsy usually resolve. Repeat MRI can indicate persistent lesions that might need a second biopsy
The structure of BVU2987 from Bacteroides vulgatus reveals a superfamily of bacterial periplasmic proteins with possible inhibitory function.
Proteins that contain the DUF2874 domain constitute a new Pfam family PF11396. Members of this family have predominantly been identified in microbes found in the human gut and oral cavity. The crystal structure of one member of this family, BVU2987 from Bacteroides vulgatus, has been determined, revealing a β-lactamase inhibitor protein-like structure with a tandem repeat of domains. Sequence analysis and structural comparisons reveal that BVU2987 and other DUF2874 proteins are related to β-lactamase inhibitor protein, PepSY and SmpA_OmlA proteins and hence are likely to function as inhibitory proteins
Precision Measurement of the Neutron Spin Asymmetry and Spin-Flavor Decomposition in the Valence Quark Region
We have measured the neutron spin asymmetry with high precision at
three kinematics in the deep inelastic region at , 0.47 and 0.60, and
, 3.5 and 4.8 (GeV/c), respectively. Our results unambiguously
show, for the first time, that crosses zero around and becomes
significantly positive at . Combined with the world proton data,
polarized quark distributions were extracted. Our results, in general, agree
with relativistic constituent quark models and with perturbative quantum
chromodynamics (pQCD) analyses based on the earlier data. However they deviate
from pQCD predictions based on hadron helicity conservation.Comment: 5 pages, 2 figures, this is the final version appeared in Phys. Rev.
Let
Precision Measurement of the Neutron Spin Asymmetries and Spin-dependent Structure Functions in the Valence Quark Region
We report on measurements of the neutron spin asymmetries and
polarized structure functions at three kinematics in the deep
inelastic region, with , 0.47 and 0.60 and , 3.5 and 4.8
(GeV/c), respectively. These measurements were performed using a 5.7 GeV
longitudinally-polarized electron beam and a polarized He target. The
results for and at are consistent with previous world
data and, at the two higher points, have improved the precision of the
world data by about an order of magnitude. The new data show a zero
crossing around and the value at is significantly positive.
These results agree with a next-to-leading order QCD analysis of previous world
data. The trend of data at high agrees with constituent quark model
predictions but disagrees with that from leading-order perturbative QCD (pQCD)
assuming hadron helicity conservation. Results for and have a
precision comparable to the best world data in this kinematic region. Combined
with previous world data, the moment was evaluated and the new result
has improved the precision of this quantity by about a factor of two. When
combined with the world proton data, polarized quark distribution functions
were extracted from the new values based on the quark parton
model. While results for agree well with predictions from various
models, results for disagree with the leading-order pQCD
prediction when hadron helicity conservation is imposed.Comment: A typing error in A_\parallel(3He) at x=0.47 in Table VII of Phys.
Rev. C has been noticed and correcte
Primitive Duplicate Hox Clusters in the European Eel's Genome
The enigmatic life cycle and elongated body of the European eel (Anguilla anguilla L., 1758) have long motivated scientific enquiry. Recently, eel research has gained in urgency, as the population has dwindled to the point of critical endangerment. We have assembled a draft genome in order to facilitate advances in all provinces of eel biology. Here, we use the genome to investigate the eel's complement of the Hox developmental transcription factors. We show that unlike any other teleost fish, the eel retains fully populated, duplicate Hox clusters, which originated at the teleost-specific genome duplication. Using mRNA-sequencing and in situ hybridizations, we demonstrate that all copies are expressed in early embryos. Theories of vertebrate evolution predict that the retention of functional, duplicate Hox genes can give rise to additional developmental complexity, which is not immediately apparent in the adult. However, the key morphological innovation elsewhere in the eel's life history coincides with the evolutionary origin of its Hox repertoire
Vaccinia Virus Proteins A52 and B14 Share a Bcl-2–Like Fold but Have Evolved to Inhibit NF-κB rather than Apoptosis
Vaccinia virus (VACV), the prototype poxvirus, encodes numerous proteins that modulate the host response to infection. Two such proteins, B14 and A52, act inside infected cells to inhibit activation of NF-κB, thereby blocking the production of pro-inflammatory cytokines. We have solved the crystal structures of A52 and B14 at 1.9 Å and 2.7 Å resolution, respectively. Strikingly, both these proteins adopt a Bcl-2–like fold despite sharing no significant sequence similarity with other viral or cellular Bcl-2–like proteins. Unlike cellular and viral Bcl-2–like proteins described previously, A52 and B14 lack a surface groove for binding BH3 peptides from pro-apoptotic Bcl-2–like proteins and they do not modulate apoptosis. Structure-based phylogenetic analysis of 32 cellular and viral Bcl-2–like protein structures reveals that A52 and B14 are more closely related to each other and to VACV N1 and myxoma virus M11 than they are to other viral or cellular Bcl-2–like proteins. This suggests that a progenitor poxvirus acquired a gene encoding a Bcl-2–like protein and, over the course of evolution, gene duplication events have allowed the virus to exploit this Bcl-2 scaffold for interfering with distinct host signalling pathways
Natriuretic peptides and integrated risk assessment for cardiovascular disease: an individual-participant-data meta-analysis
BACKGROUND: Guidelines for primary prevention of cardiovascular diseases focus on prediction of coronary heart disease and stroke. We assessed whether or not measurement of N-terminal-pro-B-type natriuretic peptide (NT-proBNP) concentration could enable a more integrated approach than at present by predicting heart failure and enhancing coronary heart disease and stroke risk assessment.
METHODS: In this individual-participant-data meta-analysis, we generated and harmonised individual-participant data from relevant prospective studies via both de-novo NT-proBNP concentration measurement of stored samples and collection of data from studies identified through a systematic search of the literature (PubMed, Scientific Citation Index Expanded, and Embase) for articles published up to Sept 4, 2014, using search terms related to natriuretic peptide family members and the primary outcomes, with no language restrictions. We calculated risk ratios and measures of risk discrimination and reclassification across predicted 10 year risk categories (ie, <5%, 5% to <7·5%, and ≥7·5%), adding assessment of NT-proBNP concentration to that of conventional risk factors (ie, age, sex, smoking status, systolic blood pressure, history of diabetes, and total and HDL cholesterol concentrations). Primary outcomes were the combination of coronary heart disease and stroke, and the combination of coronary heart disease, stroke, and heart failure.
FINDINGS: We recorded 5500 coronary heart disease, 4002 stroke, and 2212 heart failure outcomes among 95 617 participants without a history of cardiovascular disease in 40 prospective studies. Risk ratios (for a comparison of the top third vs bottom third of NT-proBNP concentrations, adjusted for conventional risk factors) were 1·76 (95% CI 1·56-1·98) for the combination of coronary heart disease and stroke and 2·00 (1·77-2·26) for the combination of coronary heart disease, stroke, and heart failure. Addition of information about NT-proBNP concentration to a model containing conventional risk factors was associated with a C-index increase of 0·012 (0·010-0·014) and a net reclassification improvement of 0·027 (0·019-0·036) for the combination of coronary heart disease and stroke and a C-index increase of 0·019 (0·016-0·022) and a net reclassification improvement of 0·028 (0·019-0·038) for the combination of coronary heart disease, stroke, and heart failure.
INTERPRETATION: In people without baseline cardiovascular disease, NT-proBNP concentration assessment strongly predicted first-onset heart failure and augmented coronary heart disease and stroke prediction, suggesting that NT-proBNP concentration assessment could be used to integrate heart failure into cardiovascular disease primary prevention.
FUNDING: British Heart Foundation, Austrian Science Fund, UK Medical Research Council, National Institute for Health Research, European Research Council, and European Commission Framework Programme 7
A Multilaboratory Comparison of Calibration Accuracy and the Performance of External References in Analytical Ultracentrifugation
Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304 ± 0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of ± 0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies
A multilaboratory comparison of calibration accuracy and the performance of external references in analytical ultracentrifugation.
Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304 ± 0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of ± 0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies
- …