93 research outputs found

    Toward forward-looking OCT needle tip vision of the spinal neuroforamen: animal studies

    Get PDF
    Neurologic complications have been reported with spinal transforaminal injections. Causes include intraneural injection, plus embolization occlusion of the radicular artery with subsequent spinal cord infarction. 1 Optical coherence tomography (OCT) is a non-invasive imaging modality, which is used to image tissue microstructure with very high resolution (less than 20 microns) in real-time. With a view toward needle tip OCT visualization of the spinal neuroforamen, we conducted animal studies to explore OCT imaging of paraspinal neurovascular structures. With institutional animal care committee approval, we performed ex-vivo and in situ OCT studies in a euthanized dog, pig, and rabbit. Image data was gathered on spinal nerve roots, dura, and brachial plexus. Two systems were used: frequency domain OCT imaging system developed at California Institute of Technology, and time domain Imalux NIRIS system with a 2.7 mm diameter probe. In a euthanized pig, excised dura was punctured with a 17-gauge Tuohy needle. FDOCT dural images of the puncture showed a subsurface cone-shaped defect. In a rabbit in situ study, puncture of the dura with a 26-gauge needle is imaged as a discontinuity. FDOCT imaging of both small artery and large arteries will be presented, along with H&E and OCT images of the brachial plexus

    Toward forward-looking OCT needle tip vision of the spinal neuroforamen: animal studies

    Get PDF
    Neurologic complications have been reported with spinal transforaminal injections. Causes include intraneural injection, plus embolization occlusion of the radicular artery with subsequent spinal cord infarction. 1 Optical coherence tomography (OCT) is a non-invasive imaging modality, which is used to image tissue microstructure with very high resolution (less than 20 microns) in real-time. With a view toward needle tip OCT visualization of the spinal neuroforamen, we conducted animal studies to explore OCT imaging of paraspinal neurovascular structures. With institutional animal care committee approval, we performed ex-vivo and in situ OCT studies in a euthanized dog, pig, and rabbit. Image data was gathered on spinal nerve roots, dura, and brachial plexus. Two systems were used: frequency domain OCT imaging system developed at California Institute of Technology, and time domain Imalux NIRIS system with a 2.7 mm diameter probe. In a euthanized pig, excised dura was punctured with a 17-gauge Tuohy needle. FDOCT dural images of the puncture showed a subsurface cone-shaped defect. In a rabbit in situ study, puncture of the dura with a 26-gauge needle is imaged as a discontinuity. FDOCT imaging of both small artery and large arteries will be presented, along with H&E and OCT images of the brachial plexus

    In vivo optical virtual biopsy of human oral mucosa with harmonic generation microscopy

    Get PDF
    Recent clinical studies on human skin indicated that in vivo multi-harmonic generation microscopy (HGM) can achieve sub-micron resolution for histopathological analysis with a high penetration depth and leave no energy or photodamages in the interacted tissues. It is thus highly desired to apply HGM for in vivo mucosa histopathological diagnosis. In this paper, the first in vivo optical virtual biopsy of human oral mucosa by using epi-HGM is demonstrated. We modified an upright microscope to rotate the angle of objective for in vivo observation. Our clinical study reveals the capability of HGM to in vivo image cell distributions in human oral mucosa, including epithelium and lamina propria with a high penetration depth greater than 280 μm and a high spatial resolution better than 500 nm. We also found that the third-harmonic-generation (THG) contrast on nucleus depends strongly on its thicknesses, in agreement with a numerical simulation. Besides, 4% acetic acid was found to be able to enhance the THG contrast of nucleus in oral mucosa, while such enhancement was found to decay due to the metabolic clearance of the contrast enhancer by the oral mucosa. Our clinical study indicated that, the combined epi-THG and epi-second-harmonic-generation (SHG) microscopy is a promising imaging tool for in vivo noninvasive optical virtual biopsy and disease diagnosis in human mucosa

    Comparison of the marginal adaptation of direct and indirect composite inlay restorations with optical coherence tomography

    Get PDF
    OBJECTIVE: The purpose of the study was to use the photonic imaging modality of optical coherence tomography (OCT) to compare the marginal adaptation of composite inlays fabricated by direct and indirect techniques. MATERIAL AND METHODS: Class II cavities were prepared on 34 extracted human molar teeth. The cavities were randomly divided into two groups according to the inlay fabrication technique. The first group was directly restored on cavities with a composite (Esthet X HD, Dentsply, Germany) after isolating. The second group was indirectly restored with the same composite material. Marginal adaptations were scanned before cementation with an invisible infrared light beam of OCT (Thorlabs), allowing measurement in 200 µm intervals. Restorations were cemented with a self-adhesive cement resin (SmartCem2, Dentsply), and then marginal adaptations were again measured with OCT. Mean values were statistically compared by using independent-samples t-test and paired samples t-test (p<0.05), before and after cementation. RESULTS: Direct inlays presented statistically smaller marginal discrepancy values than indirect inlays, before (p=0.00001442) and after (p=0.00001466) cementation. Marginal discrepancy values were increased for all restorations after cementation (p=0.00008839, p=0.000000952 for direct and indirect inlays, respectively). The mean marginal discrepancy value of the direct group increased from 56.88±20.04 µm to 91.88±31.7 µm, whereas the indirect group increased from 107.54±35.63 µm to 170.29±54.83 µm. Different techniques are available to detect marginal adaptation of restorations, but the OCT system can give quantitative information about resin cement thickness and its interaction between tooth and restoration in a nondestructive manner. CONCLUSIONS: Direct inlays presented smaller marginal discrepancy than indirect inlays. The marginal discrepancy values were increased for all restorations that refer to cement thickness after cementation

    Methods and application areas of endoscopic optical coherence tomography

    Get PDF
    We review the current state of research in endoscopic optical coherence tomography (OCT). We first survey the range of available endoscopic optical imaging techniques. We then discuss the various OCT-based endoscopic methods that have thus far been developed. We compare the different endoscopic OCT methods in terms of their scan performance. Next, we examine the application range of endoscopic OCT methods. In particular, we look at the reported utility of the methods in digestive, intravascular, respiratory, urinary and reproductive systems. We highlight two additional applications—biopsy procedures and neurosurgery—where sufficiently compact OCT-based endoscopes can have significant clinical impacts

    Surfing the spectrum - what is on the horizon?

    Get PDF
    Diagnostic imaging techniques have evolved with technological advancements - but how far? The objective of this article was to explore the electromagnetic spectrum to find imaging techniques which may deliver diagnostic information of equal, or improved, standing to conventional radiographs and to explore any developments within radiography which may yield improved diagnostic data. A comprehensive literature search was performed using Medline, Web of Knowledge, Science Direct and PubMed Databases. Boolean Operators were used and key-terms included (not exclusively): terahertz, X-ray, ultraviolet, visible, infra-red, magnetic resonance, dental, diagnostic, caries and periodontal. Radiographic techniques are primarily used for diagnostic imaging in dentistry, and continued developments in X-ray imaging include: phase contrast, darkfield and spectral imaging. Other modalities have potential application, for example, terahertz, laser doppler and optical techniques, but require further development. In particular, infra-red imaging has regenerated interest with caries detection in vitro, due to improved quality and accessibility of cameras. Non-ionising imaging techniques, for example, infra-red, are becoming more commensurate with traditional radiographic techniques for caries detection. Nevertheless, X-rays continue to be the leading diagnostic image for dentists, with improved diagnostic potential for lower radiation dose becoming a reality
    corecore