61 research outputs found
ArteFill® Permanent Injectable for Soft Tissue Augmentation: II. Indications and Applications
Patients ask for procedures with long-lasting effects. ArteFill is the first permanent injectable approved in 2006 by the FDA for nasolabial folds. It consists of cleaned microspheres of polymethylmethacrylate (PMMA) suspended in bovine collagen. Over the development period of 20 years most of its side effects have been eliminated to achieve the same safety standard as today’s hyaluronic acid products. A 5-year follow-up study in U.S. clinical trial patients has shown the same wrinkle improvement as seen at 6 months. Long-term follow-up in European Artecoll patients has shown successful wrinkle correction lasting up to 15 years. A wide variety of off-label indications and applications have been developed that help the physician meet the individual needs of his/her patients. Serious complications after ArteFill injections, such as granuloma formation, have not been reported due to the reduction of PMMA microspheres smaller than 20 μm to less than 1% “by the number.” Minor technique-related side effects, however, may occur during the initial learning curve. Patient and physician satisfaction with ArteFill has been shown to be greater than 90%
Observation of Two New Excited Ξb0 States Decaying to Λb0 K-π+
Two narrow resonant states are observed in the Λb0K-π+ mass spectrum using a data sample of proton-proton collisions at a center-of-mass energy of 13 TeV, collected by the LHCb experiment and corresponding to an integrated luminosity of 6 fb-1. The minimal quark content of the Λb0K-π+ system indicates that these are excited Ξb0 baryons. The masses of the Ξb(6327)0 and Ξb(6333)0 states are m[Ξb(6327)0]=6327.28-0.21+0.23±0.12±0.24 and m[Ξb(6333)0]=6332.69-0.18+0.17±0.03±0.22 MeV, respectively, with a mass splitting of Δm=5.41-0.27+0.26±0.12 MeV, where the uncertainties are statistical, systematic, and due to the Λb0 mass measurement. The measured natural widths of these states are consistent with zero, with upper limits of Γ[Ξb(6327)0]<2.20(2.56) and Γ[Ξb(6333)0]<1.60(1.92) MeV at a 90% (95%) credibility level. The significance of the two-peak hypothesis is larger than nine (five) Gaussian standard deviations compared to the no-peak (one-peak) hypothesis. The masses, widths, and resonant structure of the new states are in good agreement with the expectations for a doublet of 1D Ξb0 resonances
A search for rare B → Dμ+μ− decays
A search for rare B→Dμ+μ− decays is performed using proton-proton collision data collected by the LHCb experiment, corresponding to an integrated luminosity of 9 fb−1. No significant signals are observed in the non-resonant μ+μ− modes, and upper limits of B(B0→D ̄ ̄ ̄ ̄0μ+μ−)<5.1×10−8, B(B+→D+sμ+μ−)<3.2×10−8, B(B0s→D ̄ ̄ ̄ ̄0μ+μ−)<1.6×10−7 and fc/fu⋅B(B+c→D+sμ+μ−)<9.6×10−8 are set at the 95\% confidence level, where fc and fu are the fragmentation fractions of a B meson with a c and u quark respectively in proton-proton collisions. Each result is either the first such measurement or an improvement by three orders of magnitude on an existing limit. Separate upper limits are calculated when the muon pair originates from a J/ψ→μ+μ− decay. The branching fraction of B+c→D+sJ/ψ multiplied by the fragmentation-fraction ratio is measured to be fc/fu⋅B(B+c→D+sJ/ψ)=(1.63±0.15±0.13)×10−5, where the first uncertainty is statistical and the second systematic
AIDS and non-AIDS severe morbidity associated with hospitalizations among HIV-infected patients in two regions with universal access to care and antiretroviral therapy, France and Brazil, 2000–2008: hospital-based cohort studies
Search for dark photons produced in 13 TeV collisions
Searches are performed for both promptlike and long-lived dark photons,
A
0
, produced in proton-proton
collisions at a center-of-mass energy of 13 TeV, using
A
0
→
μ
þ
μ
−
decays and a data sample corresponding
to an integrated luminosity of
1
.
6
fb
−
1
collected with the LHCb detector. The promptlike
A
0
search covers
the mass range from near the dimuon threshold up to 70 GeV, while the long-lived
A
0
search is restricted to
the low-mass region
214
<m
ð
A
0
Þ
<
350
MeV. No evidence for a signal is found, and 90% confidence
level exclusion limits are placed on the
γ
–
A
0
kinetic-mixing strength. The constraints placed on promptlike
dark photons are the most stringent to date for the mass range
10
.
6
<m
ð
A
0
Þ
<
70
GeV, and are
comparable to the best existing limits for
m
ð
A
0
Þ
<
0
.
5
GeV. The search for long-lived dark photons is the
first to achieve sensitivity using a displaced-vertex signature
High vertical subperiosteal midfacelift: Transcutaneous versus transoral suspension sutures
A prospective study of the relationship between patient character and blood pressure in dental implant surgery
Systematic Review and Meta-Analysis of Surgical Zipper Technique versus Intracutaneous Sutures for the Closing of Surgical Incision
- …
