35 research outputs found

    Calculation of Effective Coulomb Interaction for Pr3+Pr^{3+}, U4+U^{4+}, and UPt3UPt_3

    Full text link
    In this paper, the Slater integrals for a screened Coulomb interaction of the the Yukawa form are calculated and by fitting the Thomas-Fermi wavevector, good agreement is obtained with experiment for the multiplet spectra of Pr3+Pr^{3+} and U4+U^{4+} ions. Moreover, a predicted multiplet spectrum for the heavy fermion superconductor UPt3UPt_3 is shown with a calculated Coulomb U of 1.6 eV. These effective Coulomb interactions, which are quite simple to calculate, should be useful inputs to further many-body calculations in correlated electron metals.Comment: 8 pages, revtex, 3 uuencoded postscript figure

    A multilaboratory comparison of calibration accuracy and the performance of external references in analytical ultracentrifugation.

    Get PDF
    Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304 ± 0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of ± 0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies

    Representation in the (Artificial) Immune System

    Get PDF
    Much of contemporary research in Artificial Immune Systems (AIS) has partitioned into either algorithmic machine learning and optimisation, or, modelling biologically plausible dynamical systems, with little overlap between. We propose that this dichotomy is somewhat to blame for the lack of significant advancement of the field in either direction and demonstrate how a simplistic interpretation of Perelson’s shape-space formalism may have largely contributed to this dichotomy. In this paper, we motivate and derive an alternative representational abstraction. To do so we consider the validity of shape-space from both the biological and machine learning perspectives. We then take steps towards formally integrating these perspectives into a coherent computational model of notions such as life-long learning, degeneracy, constructive representations and contextual recognition—rhetoric that has long inspired work in AIS, while remaining largely devoid of operational definition
    corecore