22 research outputs found

    Peripheral organ equivalent dose estimation procedure in proton therapy

    Get PDF
    The aim of this work is to present a reproducible methodology for the evaluation of total equivalent doses in organs during proton therapy facilities. The methodology is based on measuring the dose equivalent in representative locations inside an anthropomorphic phantom where photon and neutron dosimeters were inserted. The Monte Carlo simulation was needed for obtaining neutron energy distribution inside the phantom. The methodology was implemented for a head irradiation case in the passive proton beam of iThemba Labs (South Africa). Thermoluminescent dosimeter (TLD)-600 and TLD-700 pairs were used as dosimeters inside the phantom and GEANT code for simulations. In addition, Bonner sphere spectrometry was performed inside the treatment room to obtain the neutron spectra, some relevant neutron dosimetric quantities per treatment Gy, and a percentual distribution of neutron fluence and ambient dose equivalent in four energy groups, at two locations. The neutron spectrum at one of those locations was also simulated so that a reasonable agreement between simulation and measurement allowed a validation of the simulation. Results showed that the total out-of-field dose equivalent inside the phantom ranged from 1.4 to 0.28 mSv/Gy, mainly due to the neutron contribution and with a small contribution from photons, 10% on average. The order of magnitude of the equivalent dose in organs was similar, displaying a slow reduction in values as the organ is farther from the target volume. These values were in agreement with those found by other authors in other passive beam facilities under similar irradiation and measurement conditions

    Results of the first user program on the Homogenous Thermal Neutron Source HOTNES (ENEA / INFN)

    Full text link
    The HOmogeneous Thermal NEutron Source (HOTNES) is a new type of thermal neutron irradiation assembly developed by the ENEA-INFN collaboration. The facility is fully characterized in terms of neutron field and dosimetric quantities, by either computational and experimental methods. This paper reports the results of the first "HOTNES users program", carried out in 2016, and covering a variety of thermal neutron active detectors such as scintillators, solid-state, single crystal diamond and gaseous detectors

    Estimation of neutron-equivalent dose in organs of patients undergoing radiotherapy by the use of a novel online digital detector.

    Get PDF
    Neutron peripheral contamination in patients undergoing high-energy photon radiotherapy is considered as a risk factor for secondary cancer induction. Organ-specific neutron-equivalent dose estimation is therefore essential for a reasonable assessment of these associated risks. This work aimed to develop a method to estimate neutron-equivalent doses in multiple organs of radiotherapy patients. The method involved the convolution, at 16 reference points in an anthropomorphic phantom, of the normalized Monte Carlo neutron fluence energy spectra with the kerma and energy-dependent radiation weighting factor. This was then scaled with the total neutron fluence measured with passive detectors, at the same reference points, in order to obtain the equivalent doses in organs. The latter were correlated with the readings of a neutron digital detector located inside the treatment room during phantom irradiation. This digital detector, designed and developed by our group, integrates the thermal neutron fluence. The correlation model, applied to the digital detector readings during patient irradiation, enables the online estimation of neutron-equivalent doses in organs. The model takes into account the specific irradiation site, the field parameters (energy, field size, angle incidence, etc) and the installation (linac and bunker geometry). This method, which is suitable for routine clinical use, will help to systematically generate the dosimetric data essential for the improvement of current risk-estimation models

    Dosimetry tools and techniques for IMRT

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/98734/1/MPH001313.pd

    Improving the neutron-to-photon discrimination capability of detectors used for neutron dosimetry in high energy photon beam radiotherapy

    No full text
    The increasing interest of the medical community to radioinduced second malignancies due to photoneutrons in patients undergoing high-energy radiotherapy, has stimulated in recent years the study of peripheral doses, including the development of some dedicated active detectors. Although these devices are designed to respond to neutrons only, their parasitic photon response is usually not identically zero and anisotropic. The impact of these facts on measurement accuracy can be important, especially in points close to the photon field-edge.A simple method to estimate the photon contribution to detector readings is to cover it with a thermal neutron absorber with reduced secondary photon emission, such as a borated rubber. This technique was applied to the TNRD (Thermal Neutron Rate Detector), recently validated for thermal neutron measurements in high-energy photon radiotherapy. The positive results, together with the accessibility of the method, encourage its application to other detectors and different clinical scenarios

    Neutron measurements in radiotherapy: A method to correct neutron sensitive devices for parasitic photon response

    No full text
    One of the major causes of secondary malignancies after radiotherapy treatments are peripheral doses, known to increase for some newer techniques (such as IMRT or VMAT). For accelerators operating above 10 MV, neutrons can represent important contribution to peripheral doses. This neutron contamination can be measured using different passive or active techniques, available in the literature. As far as active (or direct-reading) procedures are concerned, a major issue is represented by their parasitic photon sensitivity, which can significantly affect the measurement when the point of test is located near to the field-edge. This work proposes a simple method to estimate the unwanted photon contribution to these neutrons. As a relevant case study, the use of a recently neutron sensor for â\u80\u9cin-phantomâ\u80\u9d measurements in high-energy machines was considered. The method, called â\u80\u9cDual Energy Photon Subtractionâ\u80\u9d (DEPS), requires pairs of measurements performed for the same treatment, in low-energy (6 MV) and high energy (e.g. 15 MV) fields. It assumes that the peripheral photon dose (PPD) at a fixed point in a phantom, normalized to the unit photon dose at the isocenter, does not depend on the treatment energy. Measurements with ionization chamber and Monte Carlo simulations were used to evaluate the validity of this hypothesis. DEPS method was compared to already published correction methods, such as the use of neutron absorber materials. In addition to its simplicity, an advantage of DEPs procedure is that it can be applied to any radiotherapy machine

    10-MV SBRT FFF irradiation technique is associated to the lowest peripheral dose: the outcome of 142 treatment plans for the 10 most common tumour locations

    No full text
    There is a growing interest in the combined use of Stereotactic Body Radiation Therapy (SBRT) with Flattening Filter Free (FFF) due to the high local control rates and reduced treatment times, compared to conventionally fractionated treatments. It has been suggested that they may also provide a better radiation protection to radiotherapy patients as a consequence of the expected decrease in peripheral doses. This work aims to determine this reduction in unattended out-of-field regions, where no CT information is available but an important percentage of second primary cancers occur. For that purpose, ten different cases suitable for SBRT were chosen. Thus, 142 different treatment plans including SBRT, as well as 3D‐CRT, IMRT and VMAT (with standard fractionation) in low and high energies for Varian (FF and FFF), Siemens and Elekta machines were created. Then, photon and neutron peripheral dose in 14 organs were assessed and compared using two analytical models. For the prostate case, uncomplicated and cancer free control probability estimation was also carried out. As a general behavior, SBRT plans led to the lowest peripheral doses followed by 3D-CRT, VMAT and IMRT, in this order. Unflattened beams proved to be the most effective in reducing peripheral doses, especially for 10 MV. The obtained results suggest that FFF beams for SBRT with 10 MV represent the best compromise between dose delivery efficiency and peripheral dose reduction.Peer reviewe
    corecore