214 research outputs found

    Diagnostic value of non-invasive imaging techniques in the detection of carotid artery stenosis: a systematic review

    Get PDF
    The purpose of the study was to evaluate the diagnostic performance of non- invasive imaging methods of detecting carotid artery stenosis in comparison to digital subtraction angiography (DSA) by undertaking a systematic review of the literature. The non-invasive methods reviewed include multislice computed tomography (MSCT) angiography, duplex ultrasound (US) and magnetic resonance (MR) angiography.A search of medical databases (PubMed, Medline, ScienceDirect, Proquest) of the English literature was performed and 22 studies with 68 comparisons were found to meet the selection criteria and included in our study. 5 studies were performed with MSCT angiography, 11 with duplex US and 13 with MR angiography. Both duplex US and MR angiography were studied in 7 out of 24 US and MR studies. The diagnostic value of each imaging modality was reviewed in terms of the sensitivity and specificity compared to DSA, which is regarded as the standard method.The mean sensitivity and specificity for MSCT angiography, duplex US and MR angiography were 88% (95% CI: 83%, 92%) and 90% (95% CI: 85%, 94%), 88% (95% CI: 81%, 94%) and 89% (95% CI: 85%, 94%), 94% (95% CI: 90%, 97%) and 89% (95% CI: 85%, 92%), respectively based on overall assessment. The evaluation showed that contrast-enhanced MR angiography has high diagnostic value for detection of more than 50% stenosis of carotid artery stenosis with mean sensitivity and specificity being 95% (95% CI: 92%, 98%) and 91% (95% CI: 86% 95%). When assessment was based on a combination of MR angiography and duplex US, the sensitivity reached the highest value of 98% (95% CI: 96%, 100%). This analysis indicates that MR angiography, especially contrast-enhanced MR angiography could be used as a reliable alternative modality to DSA in the detection of carotid artery stenosis

    Prevalence of Asymptomatic Carotid Stenosis in Korea Based on Health Screening Population

    Get PDF
    We attempted to investigate the prevalence and risk factors of carotid artery stenosis in Korea. Twenty thousand seven hundred twelve individuals who underwent carotid artery ultrasonography for health screening between March 2005 and March 2010 were retrospectively evaluated. The population was divided into four groups, according to the degree of stenosis, as Group A, below 29%; Group B, 30% to 49%; Group C, 50% to 74%; Group D, above 75%. The medical records of the individuals were investigated, and Fisher's exact test, chi-square tests, Kruskal-Wallis tests and a binary logistic regression model were used for statistical analysis. The prevalence of carotid stenosis was Group B, 5.5%; Group C, 0.9%; Group D, 0.1%. Old age, male gender, hypertension, diabetes mellitus and ischemic heart disease were significantly higher in Groups C and D (P = 0.001, 0.001, 0.001, 0.048, and 0.001, respectively). Among the males aged over 65 yr, the prevalence of carotid stenosis ≥ 50% and ≥ 30% were 4.0% and 18.2%, respectively. Asymptomatic carotid stenosis is not uncommon in Korea. Carotid ultrasonography is necessary for people with above-listed risk factors

    Tissue Doppler imaging of carotid plaque wall motion: a pilot study

    Get PDF
    BACKGROUND: Studies suggest the physical and mechanical properties of vessel walls and plaque may be of clinical value in the diagnosis and treatment of cardiovascular atherosclerotic disease. The purpose of this pilot study was to investigate the potential clinical application of ultrasound Tissue Doppler Imaging (TDI) of Arterial Wall Motion (AWM) and to quantify simple wall motion indices in normal and diseased carotid arteries. METHODS: 224 normal and diseased carotid arteries (0–100% stenoses) were imaged in 126 patients (age 25–88 years, mean 68 ± 11). Longitudinal sections of the carotid bifurcation were imaged using a Philips HDI5000 scanner and L12-5 probe under optimized TDI settings. Temporal and spatial AWMs were analyzed to evaluate the vessel wall displacements and spatial gradients at peak systole averaged over 5 cardiac cycles. RESULTS: AWM data were successfully extracted in 91% of cases. Within the carotid bifurcation/plaque region, the maximum wall dilation at peak systole ranged from -100 to 750 microns, mean 335 ± 138 microns. Maximum wall dilation spatial gradients ranged 0–0.49, mean 0.14 ± 0.08. The AWM parameters showed a wide variation and had poor correlation with stenoses severity. Case studies illustrated a variety of pertinent qualitative and quantitative wall motion features related to the biophysics of arterial disease. CONCLUSION: Our clinical experience, using a challenging but realistic imaging protocol, suggests the use of simple quantitative AWM measures may have limitations due to high variability. Despite this, pertinent features of AWM in normal and diseased arteries demonstrate the potential clinical benefit of the biomechanical information provided by TDI

    Quality of life after carotid endarterectomy

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Most studies documenting beneficial outcomes after carotid endarterectomy (CE) are limited to mortality and morbidity rates, costs, and length of hospital stay (LOS). Few have examined the dependency of patients and how they perceive their own health changes after surgery. The aim of the present study was to evaluate quality of life and independence in activities of daily living (ADL) and to study its determinants.</p> <p>Methods</p> <p>Sixty-three patients admitted in the Post Anaesthesia Care Unit (PACU) after CE were eligible for this 14-month follow-up study. Patients were contacted 6 months after discharge to complete a Short Form-36 questionnaire (SF-36) and to have their dependency in ADL evaluated.</p> <p>Results</p> <p>Among 59 hospital survivors at 6 months follow-up, 43 completed the questionnaires. Sixty-three percent reported that their general level of health was better on the day they answered the questionnaire than 12 months earlier. Patients had worse SF-36 scores for all domains except bodily pain than a general urban population, and comparison with a group of patients 6 months after surgical ICU discharge showed no differences. Six months after PACU discharge, the Lawton Instrumental Activities of ADL Scale and the Katz Index of ADL demonstrated higher dependency scores (5.9 ± 2.2 versus 4.3 ± 2.4 and 0.3 ± 0.8 versus 0.6 ± 0.9, p < 0.001 and p = 0.047). Sixty-five percent and 33% were dependent in at least one activity in instrumental and personal ADL, respectively. Patients dependent in at least one ADL task had higher Revised Cardiac Risk Index (RCRI) scores (1.0 versus 1.5, p = 0.017). After controlling for multiple comparisons, no significant differences were found.</p> <p>Conclusion</p> <p>Patients undergoing CE have improved self-perception of quality of life despite being more dependent. Almost all their scores are worse than those in an urban population. We could identify no predictors of greater dependency in ADL tasks six months after PACU discharge.</p

    High-resolution imaging of human atherosclerotic carotid plaques with micro18F-FDG PET scanning exploring plaque vulnerability

    Get PDF
    FDG-PET can be used to identify vulnerable plaques in atherosclerotic disease. Clinical FDG-PET camera systems are restricted in terms of resolution for the visualization of detailed inflammation patterns in smaller vascular structures. The aim of the study is to evaluate the possible added value of a high-resolution microPET system in excised carotid plaques using FDG. In this study, 17 patients with planned carotid endarterectomy were included. Excised plaques were incubated in FDG and subsequently imaged with microPET. Macrophage presence in plaques was evaluated semi-quantitatively by immunohistochemistry. Plaque calcification was assessed additionally with CT and correlated to FDG uptake. Finally, FDG uptake and macrophage infiltration were compared with patient symptomatology. Heterogeneous distributions and variable intensities of FDG uptake were found within the plaques. A positive correlation between the distribution of macrophages and the FDG uptake (r = 0.68, P <.01) was found. A negative correlation was found between areas of calcifications and FDG uptake (r = -0.84, P <.001). Ratio FDG(max) values as well as degree of CD68 accumulation were significantly higher in CVA patients compared with TIA or amaurosis fugax patients (P <.05) and CVA patients compared with asymptomatic patients (P <.05). This ex vivo study demonstrates that excised carotid plaques can be visualized in detail using FDG microPET. Enhancement of clinical PET/CT resolution for similar imaging results in patients is needed

    An assessment of the cost-effectiveness of magnetic resonance, including diffusion-weighted imaging in patients with transient ischaemic attack and minor stroke : a systematic review, meta-analysis and economic evaluation

    Get PDF
    Erratum issued September 2015 Erratum DOI: 10.3310/hta18270-c201509Peer reviewedPublisher PD

    An assessment of the cost-effectiveness of magnetic resonance, including diffusion-weighted imaging, in patients with transient ischaemic attack and minor stroke: a systematic review, meta-analysis and economic evaluation

    Full text link

    Testing devices for the prevention and treatment of stroke and its complications

    Get PDF
    We are entering a challenging but exciting period when many new interventions may appear for stroke based on the use of devices. Hopefully these will lead to improved outcomes at a cost that can be afforded in most parts of the world. Nevertheless, it is vital that lessons are learnt from failures in the development of pharmacological interventions (and from some early device studies), including inadequate preclinical testing, suboptimal trial design and analysis, and underpowered studies. The device industry is far more disparate than that seen for pharmaceuticals; companies are very variable in size and experience in stroke, and are developing interventions across a wide range of stroke treatment and prevention. It is vital that companies work together where sales and marketing are not involved, including in understanding basic stroke mechanisms, prospective systematic reviews, and education of physicians. Where possible, industry and academics should also work closely together to ensure trials are designed to be relevant to patient care and outcomes. Additionally, regulation of the device industry lags behind that for pharmaceuticals, and it is critical that new interventions are shown to be safe and effective rather than just feasible. Phase IV postmarketing surveillance studies will also be needed to ensure that devices are safe when used in the ‘real-world’ and to pick up uncommon adverse events
    corecore