6 research outputs found

    Contrôle du détecteur interférométrique d'ondes gravitationnelles Advanced Virgo

    No full text
    The first detection of a Gravitational Wave (GW) was done on September 14 th of 2015 by the LIGO-Virgo collaboration with the two LIGO detectors. It was emitted by the merger of a Binary Black Hole, providing the first direct proof of the existence of Black Holes. Advanced Virgo is the upgraded version of the Virgo interferometer and it will join the LIGO detectors in the next months. The passage of a GW on Earth induces a change on the distance between test masses (experiencing only the gravitational interaction) in a differential way. This distance variation is proportional to the amplitude of the GW however the largest displacement observable on Earth will be of the order of 10⁻¹⁹ m/sqrt(Hz). Taking this in account, a Michelson interferometer is the ideal instrument to detect this differential effect. GWs detectors will use suspended mirrors to behave as test masses. The passage of a GW will cause a change on the distance between the mirrors that will spoil the interference condition, allowing some light to leak to the detection photodiode. However, a simple Michelson interferometer does not provide enough sensitivity. For this reason the first generation of detectors added Fabry-Perot cavities in the arms, in order to increase the optical path. A second change was the addition of an extra mirror in order to recycle the light that comes back towards the laser, to increase the effective power, creating a new cavity also known as Power Recycling Cavity (PRC). Its effect is more important when the Michelson is tuned in an optimal way in a dark fringe. All the mirrors of the detector are affected by the seismic noise and so their distance is continuously changing. It is necessary to control the longitudinal and angular position of the cavities in order to keep them at resonance. During my thesis I have studied the control of Advanced Virgo using simulation and during the commissioning itself. First of all I have simulated the control strategy used in Virgo using modal simulations. The aim was to check if the same strategy could be applied to Advanced Virgo or if it needs adaptation. In Advanced Virgo the Fabry-Perot cavities have a higher finesse, which arises new dynamical problems and requires a special control strategy that I have modified to match the commissioning needs. Regarding the PRC, we have studied the impact of its stability on the performance of the interferometer. As it is very close from the instability region, the electrical field inside will be very sensitive to alignment and matching of the laser beam. We have checked using simulations its impact on the longitudinal controls, which can become unstable, and a solution has been validated. Then I have used this information during the commissioning of the Advanced Virgo detector. In this thesis the details of the commissioning of the longitudinal and angular control of the interferometer will be presented. It includes the frequency stabilization, which has a key role in the control of the interferometer, since it is the dominant noise.La première détection d'une Onde Gravitationnelle (OG) a été faite le 14 Septembre 2015 par la collaboration LIGO-Virgo avec les deux détecteurs de LIGO. Elle a été émise par la fusion de deux Trous Noirs, fournissant ainsi la première preuve directe de l’existence des Trous Noirs. Advanced Virgo est la version améliorée de l’interféromètre Virgo et il va rejoindre les détecteurs LIGO dans les mois qui suivent. Le passage d'une OG induit un changement différentiel de la distance entre masses-test (uniquement sensibles à la force gravitationnelle). Cette variation de distance est proportionnelle à l'amplitude de l'OG, néanmoins le déplacement le plus grand qui peut être observé depuis la Terre est de l'ordre de 10⁻¹⁹ m/sqrt(Hz) en terme de densité spectrale. C'est pour cela que l’interféromètre de Michelson est l'instrument idéal pour détecter cet effet différentiel. Les détecteurs d’OG utilisent des miroirs suspendus, qui se comportent comme masses-test. Le passage d'une OG va produire un changement dans la distance entre les miroirs qui va modifier la condition d’interférence et donc une variation de puissance lumineuse mesurée par la photodiode de détection. Cependant, un Michelson simple n'est pas assez sensible et des améliorations ont été ajoutées. La première génération de détecteurs a ajouté des cavités Fabry-Pérot dans les bras pour augmenter le chemin optique. De plus un nouveau miroir a été ajouté pour recirculer la lumière réfléchie vers le laser et augmenter la puissance effective, en créant une nouvelle cavité connue comme Power Recycling Cavity (PRC). Son effet est d’autant plus important que le Michelson est en fait optimalement réglé sur une frange noire. Tous les miroirs du détecteur ressentent le bruit sismique et les longueurs des cavités, entre autres, changent en permanence. Il est donc nécessaire de contrôler activement la position longitudinale et angulaire des cavités pour les maintenir en résonance. Pendant ma thèse j'ai étudié le contrôle de Advanced Virgo d’abord en simulation puis pendant le commissioning lui-même. D'abord j'ai simulé la stratégie de contrôle utilisée dans Virgo avec des simulations modales. L'objectif était de vérifier si la même stratégie pouvait être appliquée à Advanced Virgo ou s'il fallait l'adapter. Avec Advanced Virgo les cavités Fabry-Pérot ont une finesse plus grande ce qui entraîne de nouveaux effets dynamiques et qui demande une stratégie de contrôle spéciale, stratégie que j'ai modifiée pour l'adapter aux besoins du commissioning. Concernant la PRC, j’ai étudié l'impact de sa stabilité dans le fonctionnement de l’interféromètre. Comme elle est très proche de la région d’instabilité, l’onde lumineuse être très sensible à l'alignement et a l'adaptation du faisceau à la cavité. J’ai vérifié avec les simulations son impact sur les contrôles longitudinaux, qui peuvent devenir instables, et une solution a été validée. Ensuite j'ai utilisé cette information pour le commissioning d'Advanced Virgo. Dans cette thèse les détails du commissioning des contrôles longitudinal et angulaire de l’interféromètre sont présentés. La stabilisation en fréquence est aussi présentée, puisqu'elle joue un rôle très important dans le contrôle de l’interféromètre car étant le bruit dominant

    Simulations for the Locking and Alignment Strategy of the DRMI Configuration of the Advanced Virgo Plus Detector

    No full text
    The Advanced Virgo Plus project aims to increase the sensitivity of the Virgo gravitational-wave detector, given the forthcoming O4 Observing Run. One of the major upgrades is the addition of the Signal Recycling Mirror in the optical layout. This additional mirror will provide a broadband improvement to the sensitivity curve of the instrument, but poses significant challenges in the acquisition and operation of the detector’s working point. The process which brings the main optical components from the uncontrolled state to the final working point, which ensures the best detector sensitivity, is called lock acquisition: the lock acquisition is made by moving through increasingly more complex configurations toward the full control of all the interferometer’s longitudinal degrees of freedom. This paper will focus on the control of the Dual-Recycled Michelson Interferometer (DRMI, the central part of the Virgo interferometer), presenting a comprehensive study of the optical simulations used in the design and the commissioning of this configuration. Treated topics include: the characterization of optical fields, powers, and error signals for the controls; the development of a trigger logic to be used for the lock acquisition; the study of the alignment sensing and control system. The interdependence between the three items has also been studied. Moreover, the validity of the studied techniques will be assessed by a comparison with experimental data

    Temperature Control for an Intra-Mirror Etalon in Interferometric Gravitational Wave Detector Fabry–Perot Cavities

    No full text
    International audienceThe sensitivity of interferometric gravitational wave detectors is optimized, in part, by balanced finesse in the long Fabry–Perot arm cavities. The input test mass mirrors of Advanced Virgo feature parallel faces, which creates an etalon within the substrate, adding variability in the total mirror reflectivity, in order to correct imbalanced finesse due to manufacturing tolerances. Temperature variations in mirror substrate change the optical path length primarily through varying the index of refraction and are tuned to correct for a finesse imbalance of up to 2.8% by a full etalon fringe of 0.257 K. A negative feedback control system was designed to control the mirror temperature by using an electrical resistive heating belt actuator for a heat transfer process modeled as a two-pole plant. A zero controller filter was designed which achieves temperature control within 2.3% of the etalon fringe and recovers to within 10% of the working point within 32 hours after a step input of one etalon fringe. A preliminary unlock condition control designed to compensate when the interferometer unlocks shows that the control remains stable even after a drastic change in the plant due to the absence of the laser heating. Further improvements to the control must also consider the full heat transfer mechanisms by using modern control state space models

    Development of a Frequency Tunable Green Laser Source for Advanced Virgo+ Gravitational Waves Detector

    No full text
    International audienceAfter one year of data taking, the observing run three (O3), we are preparing for an improved version of the system, named the Advanced Virgo plus. One of the major upgrades will be the installation of the signal recycling mirror to form an additional optical cavity and improve the sensitivity of the interferometer. This also requires a change in the lock acquisition strategy. In particular, the arms will be locked at the beginning with lasers at a different wavelength from the main one. Such a strategy has already been implemented and tested in LIGO and KAGRA, and in this paper we will present how it has been conceived in Virgo

    Interferometer Sensing and Control for the Advanced Virgo Experiment in the O3 Scientific Run

    Get PDF
    International audienceAdvanced Virgo is a 2nd-generation laser interferometer based in Cascina (Italy) aimed at the detection of gravitational waves (GW) from astrophysical sources. Together with the two USA-based LIGO interferometers they constitute a network which operates in coincidence. The three detectors observed the sky simultaneously during the last part of the second Observing Run (O2) in August 2017, and this led to two paramount discoveries: the first three-detector observation of gravitational waves emitted from the coalescence of a binary black hole system (GW170814), and the first detection ever of gravitational waves emitted from the coalescence of a binary neutron star system (GW170817). Coincident data taking was re-started for the third Observing Run (O3), which started on 1st April 2019 and lasted almost one year. This paper will describe the new techniques implemented for the longitudinal controls with respect to the ones already in use during O2. Then, it will present an extensive description of the full scheme of the angular controls of the interferometer, focusing on the different control strategies that are in place in the different stages of the lock acquisition procedure, which is the complex sequence of operations by which an uncontrolled, “free” laser interferometer is brought to the final working point, which allows the detector to reach the best sensitivity

    Open data from the first and second observing runs of Advanced LIGO and Advanced Virgo

    Get PDF
    Advanced LIGO and Advanced Virgo are monitoring the sky and collecting gravitational-wave strain data with sufficient sensitivity to detect signals routinely. In this paper we describe the data recorded by these instruments during their first and second observing runs. The main data products are gravitational-wave strain time series sampled at 16384 Hz. The datasets that include this strain measurement can be freely accessed through the Gravitational Wave Open Science Center at http://gw-openscience.org, together with data-quality information essential for the analysis of LIGO and Virgo data, documentation, tutorials, and supporting software
    corecore