45 research outputs found

    Enhancing the Performance of Power System under Abnormal Conditions Using Three Different FACTS Devices

    Get PDF
    In this paper, a comparison between Flexible Alternating Current Transmission System (FACTS) devices including Static Synchronous Compensator (STATCOM), Static Synchronous Series Compensator (SSSC) and Unified Power Flow Controller (UPFC) for providing a better adaptation to changing operating conditions and improving the usage of current systems. The power system using FACTS devices is presented under different conditions such as single phase fault and three phase fault. A digital simulation using Matlab/Simulink software package is carried out to demonstrate the better performance including the voltage and the current of the presented system using FACTS that located between buses B1 and B2 under different faults types. The results obtained investigate that the presented system gives better response with FACTS as compared to not using them under abnormal conditions besides, the UPFC gives better performance of power system under several faults as compared to STATCOM or SSSC as It can absorb reactive power in a manner which significantly reduced the fault current. It is demonstrated that UPFC can reduce the peak fault current at bus B1 ‎to 63.85% of its value without ‎using FACTS devices under line to ground fault and 79.18% under three line to ‎ground fault whereas STATCOM and SSSC reduce it ‎to (75.21, 94.35%) and (75.40, 94.68%), respectively

    Parameters identification and optimization of photovoltaic panels under real conditions using Lambert W-function

    Get PDF
    This paper proposes a new approach based on Lambert W-function to extract the electrical parameters of photovoltaic (PV) panels. This approach can extract the optimal electrical characteristics of the PV panel under variable conditions of irradiation and temperature. Three benchmarking panels (shell SP70 monocrystalline silicon, shell ST40 thin film, and KC200GT Polycrystalline Silicon) are demonstrated and analyzed considering the electrical characteristics provided by the manufacturers. A comprehensive assessment is carried out under different weather condition to validate the capability and the robustness of the proposed approach. Furthermore, the simulated output characteristics of the three modules Photovoltaic are almost comparable and reproduce faithfully the manufacturer’s experimental data The novelty of this study is the using a new hybrid analytical and numerical method that straight forward and effective given value of Root mean square error less than those obtained by others methods that indicate the estimated results are very close to the experimental values provided by the manufacturers

    Optimal Performance of Dynamic Particle Swarm Optimization Based Maximum Power Trackers for Stand-Alone PV System Under Partial Shading Conditions

    Get PDF
    One of the important tasks for increasing the efficiency of photovoltaic (PV) system is the development and improvement of the maximum power point tracking algorithms (MPPT). These MPPT algorithms lead to the ability to catch efficiently the global maximum power point of the partially shaded PV array. One of these trackers is the particle swarm optimization (PSO) algorithm which is one of the Soft computing techniques. The conventional PSO based trackers have many advantages such as the simplicity of hardware implementation and independence from the installed system. The actual problem of the practical application of PSO is the determination of its parameters to ensure high effectiveness of extracting the global MPP. Analysis of scientific papers devoted to the PSO algorithm has shown that there is currently no methodology for the optimal parameters' selection of PSO algorithm based maximum power trackers for the PV system. This paper aims to create a convenient and reasonable method for choosing the optimal parameters of the PSO algorithm, taking into account the topology and parameters of the DC-DC converter and the configuration of solar panels. A new method for selecting the parameters of a buck converter connected to a battery has been presented. The optimal value of the sampling time for the digital MPP controllers, providing their maximum performance; has been determined based on a new methodology. Matlab/Simulink software package is used as the main research tool. The prominent outcomes identify that the modified PSO and its designed parameters best meet the requirements of the MPPT controller for the PV system

    Transformers Improvement and Environment Conservation by Using Synthetic Esters in Egypt

    Get PDF
    Distribution transformer (DT) is a crucial component in power systems as it exchanges energies between different voltage levels or between utility grid and DC microgrids. Nevertheless, the operation of an oil-immersed DT is limited by the thermal and electrical capabilities of the internal insulating liquid. This paper aims to raise the efficiency of distribution transformers and preserve the environment by using a biodegradable insulating liquid instead of the conventional mineral insulating oil (MIO). This work examines the Egyptian case, where a real distribution network located in middle Egypt is selected as a pilot project. Study and analysis of the status que of the insulation system inside DTs are done with the aid of fault-tree analysis. The deficiency of the insulation system is confirmed by conducting an electronic survey of 100 expert participants. The most appropriate solution among three different alternatives is confirmed using the weighting and ranking method. The best choice suitable for the selected area is the substitution of MIO by synthetic ester (SE). The technical and environmental advantages achieved by the presented solution are discussed. The feasibility studies have proven that the solution is positively acceptable in all aspects. An execution plan is established for the application of proposed solution on the selected Egyptian distribution network.Science Foundation IrelandUCD Energy Institut

    Comprehensive validation of transient stability calculations in electric power systems and hardware-software tool for its implementation

    Get PDF
    Reliability and survivability of electric power systems (EPS) depend on transient stability assessment (TSA). One of the most effective way to TSA is time-domain simulation. However, large-scale EPS mathematical model contains a stiff nonlinear system of high-order differential equations. Such system cannot be solved analytically. At the same time, numerical methods are imperfectly applied for such system due to limitation conditions. To make it appropriate, the EPS mathematical model is simplified and additional limitations are used. These simplifications and limitations reduce reliability of simulation results. Consequently, their validation is needed. The most reliable approach to provide it is to compare the simulation results with the field data. However, in practice, there are not enough data for such validation. This paper proposes an alternative approach for validation - the application of a reference model instead of field data. A hardware-software system HRTSim was used as a reference model. This power system simulator has all the necessary properties and capabilities to obtain reliable information required for comprehensive validation of transient stability calculations in EPSs. Main disturbances leading to instability in EPSs are investigated to conduct the validation (processes in cases of faults, single-phase auto-reclosing operation and power system interconnection). Fragments of corresponding experimental studies illustrate the efficiency of the proposed approach. Obtained results confirmed the possibility of the developed approach to identify the causes of numerical calculation errors and to determine disturbances calculated with the significant error. In addition, experimental studies have revealed that numerical calculations error depends on disturbances intensity

    Global economic burden of unmet surgical need for appendicitis

    Get PDF
    Background: There is a substantial gap in provision of adequate surgical care in many low-and middle-income countries. This study aimed to identify the economic burden of unmet surgical need for the common condition of appendicitis. Methods: Data on the incidence of appendicitis from 170 countries and two different approaches were used to estimate numbers of patients who do not receive surgery: as a fixed proportion of the total unmet surgical need per country (approach 1); and based on country income status (approach 2). Indirect costs with current levels of access and local quality, and those if quality were at the standards of high-income countries, were estimated. A human capital approach was applied, focusing on the economic burden resulting from premature death and absenteeism. Results: Excess mortality was 4185 per 100 000 cases of appendicitis using approach 1 and 3448 per 100 000 using approach 2. The economic burden of continuing current levels of access and local quality was US 92492millionusingapproach1and92 492 million using approach 1 and 73 141 million using approach 2. The economic burden of not providing surgical care to the standards of high-income countries was 95004millionusingapproach1and95 004 million using approach 1 and 75 666 million using approach 2. The largest share of these costs resulted from premature death (97.7 per cent) and lack of access (97.0 per cent) in contrast to lack of quality. Conclusion: For a comparatively non-complex emergency condition such as appendicitis, increasing access to care should be prioritized. Although improving quality of care should not be neglected, increasing provision of care at current standards could reduce societal costs substantially

    Pooled analysis of WHO Surgical Safety Checklist use and mortality after emergency laparotomy

    Get PDF
    Background The World Health Organization (WHO) Surgical Safety Checklist has fostered safe practice for 10 years, yet its place in emergency surgery has not been assessed on a global scale. The aim of this study was to evaluate reported checklist use in emergency settings and examine the relationship with perioperative mortality in patients who had emergency laparotomy. Methods In two multinational cohort studies, adults undergoing emergency laparotomy were compared with those having elective gastrointestinal surgery. Relationships between reported checklist use and mortality were determined using multivariable logistic regression and bootstrapped simulation. Results Of 12 296 patients included from 76 countries, 4843 underwent emergency laparotomy. After adjusting for patient and disease factors, checklist use before emergency laparotomy was more common in countries with a high Human Development Index (HDI) (2455 of 2741, 89.6 per cent) compared with that in countries with a middle (753 of 1242, 60.6 per cent; odds ratio (OR) 0.17, 95 per cent c.i. 0.14 to 0.21, P <0001) or low (363 of 860, 422 per cent; OR 008, 007 to 010, P <0.001) HDI. Checklist use was less common in elective surgery than for emergency laparotomy in high-HDI countries (risk difference -94 (95 per cent c.i. -11.9 to -6.9) per cent; P <0001), but the relationship was reversed in low-HDI countries (+121 (+7.0 to +173) per cent; P <0001). In multivariable models, checklist use was associated with a lower 30-day perioperative mortality (OR 0.60, 0.50 to 073; P <0.001). The greatest absolute benefit was seen for emergency surgery in low- and middle-HDI countries. Conclusion Checklist use in emergency laparotomy was associated with a significantly lower perioperative mortality rate. Checklist use in low-HDI countries was half that in high-HDI countries.Peer reviewe

    Global variation in anastomosis and end colostomy formation following left-sided colorectal resection

    Get PDF
    Background End colostomy rates following colorectal resection vary across institutions in high-income settings, being influenced by patient, disease, surgeon and system factors. This study aimed to assess global variation in end colostomy rates after left-sided colorectal resection. Methods This study comprised an analysis of GlobalSurg-1 and -2 international, prospective, observational cohort studies (2014, 2016), including consecutive adult patients undergoing elective or emergency left-sided colorectal resection within discrete 2-week windows. Countries were grouped into high-, middle- and low-income tertiles according to the United Nations Human Development Index (HDI). Factors associated with colostomy formation versus primary anastomosis were explored using a multilevel, multivariable logistic regression model. Results In total, 1635 patients from 242 hospitals in 57 countries undergoing left-sided colorectal resection were included: 113 (6·9 per cent) from low-HDI, 254 (15·5 per cent) from middle-HDI and 1268 (77·6 per cent) from high-HDI countries. There was a higher proportion of patients with perforated disease (57·5, 40·9 and 35·4 per cent; P < 0·001) and subsequent use of end colostomy (52·2, 24·8 and 18·9 per cent; P < 0·001) in low- compared with middle- and high-HDI settings. The association with colostomy use in low-HDI settings persisted (odds ratio (OR) 3·20, 95 per cent c.i. 1·35 to 7·57; P = 0·008) after risk adjustment for malignant disease (OR 2·34, 1·65 to 3·32; P < 0·001), emergency surgery (OR 4·08, 2·73 to 6·10; P < 0·001), time to operation at least 48 h (OR 1·99, 1·28 to 3·09; P = 0·002) and disease perforation (OR 4·00, 2·81 to 5·69; P < 0·001). Conclusion Global differences existed in the proportion of patients receiving end stomas after left-sided colorectal resection based on income, which went beyond case mix alone

    Deployment of STATCOM with Fuzzy Logic Control for Improving the Performance of Power System under Different Faults Conditions

    Get PDF
    This paper purposes to demonstrate the effectiveness of fuzzy logic controller (FLC) over proportional integral (PI) controller for reducing the fault current and maintaining the voltage profile at different faults conditions using Static Synchronous Compensator (STATCOM) which is considered an effective FACTS (Flexible Alternating Current Transmission System) device. The study evaluates the performance of a power system equipped with STATCOM which is connected in shunt with bus B1 under various faults conditions, including single-phase and three-phase faults. The performance of the STATCOM is evaluated by using two different controllers: PI controllers and FLCs. A comparative analysis is done between the performances of the two different controllers using Matlab/Simulink software package. The results obtained conclude that the presented system gives better performance with STATCOM as compared to not using it under several faults conditions besides, the STATCOM gives better response with FLC as compared to PI controller. It is demonstrated that STATCOM with FLC can reduce the positive sequence fault current at bus B1 ‎to 96.49% of its value without ‎using STATCOM under line to ground fault and 98.17% under three line to ‎ground fault whereas STATCOM with PI controller can reduce it ‎to (99.57, 99.05%), respectively. Also, the bus voltage B1 is improved to 102.19% by using STATCOM with fuzzy controller under line to ground fault and 101.86% under three line to ‎ground fault whereas STATCOM with PI controller can improve it ‎to (100.21, 100.93%), respectively

    Robust Sensorless Model-Predictive Torque Flux Control for High-Performance Induction Motor Drives

    No full text
    This paper introduces a novel sensorless model-predictive torque-flux control (MPTFC) for two-level inverter-fed induction motor (IM) drives to overcome the high torque ripples issue, which is evidently presented in model-predictive torque control (MPTC). The suggested control approach will be based on a novel modification for the adaptive full-order-observer (AFOO). Moreover, the motor is modeled considering core losses and a compensation term of core loss applied to the suggested observer. In order to mitigate the machine losses, particularly at low speed and light load operations, the loss minimization criterion (LMC) is suggested. A comprehensive comparative analysis between the performance of IM drive under conventional MPTC, and those of the proposed MPTFC approaches (without and with consideration of the LMC) has been carried out to confirm the efficiency of the proposed MPTFC drive. Based on MATLAB® and Simulink® from MathWorks® (2018a, Natick, MA 01760-2098 USA) simulation results, the suggested sensorless system can operate at very low speeds and has the better dynamic and steady-state performance. Moreover, a comparison in detail of MPTC and the proposed MPTFC techniques regarding torque, current, and fluxes ripples is performed. The stability of the modified adaptive closed-loop observer for speed, flux and parameters estimation methodology is proven for a wide range of speeds via Lyapunov’s theorem
    corecore