324 research outputs found

    Flame pyrolysis synthesis of mixed oxides for glycerol steam reforming

    Get PDF
    Flame spray pyrolysis was used to produce nanosized Ni-based catalysts starting from different mixed oxides. LaNiO3 and CeNiO3 were used as base materials and the formulation was varied by mixing them or incorporating variable amounts of ZrO2 or SrO during the synthesis. The catalysts were tested for the steam reforming of glycerol. One of the key problems for this application is the resistance to deactivation by sintering and coking, which may be increased by (1) improving Ni dispersion through the production of a Ni-La or Ni-Ce mixed oxide precursor, and then reduced; (2) using an oxide as ZrO2, which established a strong interaction with Ni and possesses high thermal resistance; (3) decreasing the surface acidity of ZrO2 through a basic promoter/support, such as La2O3; and (4) adding a promoter/support with very high oxygen mobility such as CeO2. A further key feature is the use of a high temperature synthesis, such as flame spray pyrolysis, to improve the overall thermal resistance of the oxides. These strategies proved effective to obtain active and stable catalysts at least for 20 h on stream with very limited coke formation

    Trends and risk factors for syphilis infection in Piedmont Region, Italy, 2002-2008

    Get PDF
    Background: This work aims to analyze trends of syphilis infections in the Piedmont Region (Italy) between 2002 and 2008, and to evaluate risk factors for infection. Methods: Syphilis trends were described according to socio-demographic characteristics, sexual behavior, condom use, number of partners and HIV infection. Independent risk factors for syphilis among men having sex with men (MSM), men having sex with women (MSW), and women were identified through logistic regression comparing cases with 12,773 negative patients. Results: Between 2002 and 2008, 1,046 cases of syphilis were diagnosed, with peaks in 2004 and 2007. The risk of a syphilis diagnosis was independently associated with being older than 24, having a low education level, homosexual behavior, HIV self-reported infection (for MSM and MSW), number of partners (for MSW and women) and non- consistent condom use (for women). Conclusions: Recent outbreaks suggest that the attention to syphilis can’t be lowered. Screening, treatment of cases and notification of partners should be reinforced and integrated with sexual health education and counselling in high-risk environments. Surveillance data must be continuously collected

    Performance and costs of a rapid syphilis test in an urban population at high risk for sexually transmitted infections

    Get PDF
    Introduction. Rapid syphilis screening could facilitate caseidentification in populations at high risk for sexually transmitted infections (STI). The aim of this study was to compare the performance and the cost-effectiveness of a rapid immunochromatography syphilis test with a traditional ELISA screening test in patients with suspected infectious syphilis or patients at high risk for STI/syphilis. Methods. Consecutive patients attending a STI clinic cosensually underwent serological testing with two different tests. Sensitivity, specificity, Positive Predictive Values, Negative Predictive Values and effectiveness of the two tests were evaluated with respect to definitive diagnosis. Results. In our population, the immunochromatography essay (Abbott Determine Syphilis TP) had a sensitivity of 95.0% (95% CI 88.7-97.8) and a specificity of 97.7% (95% CI 94.7-99.0). The ELISA test had a sensitivity of 95.0% (95% CI 88.8-97.9) and a specificity of 97.2% (95% CI 94.1-98.7). The Positive Predictive Value for ELISA was 94.1% (95% CI 87.6-97.3) and 95.0% (95% CI 88.7-97.8) for the rapid test. The Negative Predictive Value was 97.7% (95% CI 94.7-99) for both ELISA and the rapid tests. The cost-effectiveness analysis showed that the rapid test was less expensive than ELISA (? 26.46 vs ? 40.57) and yielded a similar number of right diagnoses. Conclusions. The Abbott Determine Syphilis TP test is an accurate, easy and inexpensive test that could facilitate the rapid detection of syphilis in high-risk urban patients

    Ultrafast valley relaxation dynamics in monolayer MoS2 probed by nonequilibrium optical techniques

    Get PDF
    We study the exciton valley relaxation dynamics in single-layer MoS2 by a combination of two nonequilibrium optical techniques: time-resolved Faraday rotation and time-resolved circular dichroism. The depolarization dynamics, measured at 77 K, exhibits a peculiar biexponential decay, characterized by two distinct time scales of 200 fs and 5 ps. The fast relaxation of the valley polarization is in good agreement with a model including the intervalley electron-hole Coulomb exchange as the dominating mechanism. The valley relaxation dynamics is further investigated as a function of temperature and photoinduced exciton density. We measure a strong exciton density dependence of the transient Faraday rotation signal. This indicates the key role of exciton-exciton interactions in MoS2 valley relaxation dynamics

    Nonlinear interactions of dipolar excitons and polaritons in MoS2 bilayers

    Full text link
    Nonlinear interactions between excitons strongly coupled to light are key for accessing quantum many-body phenomena in polariton systems. Atomically-thin two-dimensional semiconductors provide an attractive platform for strong light-matter coupling owing to many controllable excitonic degrees of freedom. Among these, the recently emerged exciton hybridization opens access to unexplored excitonic species, with a promise of enhanced interactions. Here, we employ hybridized interlayer excitons (hIX) in bilayer MoS2 to achieve highly nonlinear excitonic and polaritonic effects. Such interlayer excitons possess an out-of-plane electric dipole as well as an unusually large oscillator strength allowing observation of dipolar polaritons(dipolaritons) in bilayers in optical microcavities. Compared to excitons and polaritons in MoS2 monolayers, both hIX and dipolaritons exhibit about 8 times higher nonlinearity, which is further strongly enhanced when hIX and intralayer excitons, sharing the same valence band, are excited simultaneously. This gives rise to a highly nonlinear regime which we describe theoretically by introducing a concept of hole crowding. The presented insight into many-body interactions provides new tools for accessing few-polariton quantum correlations

    Quantum ESPRESSO: a modular and open-source software project for quantum simulations of materials

    Get PDF
    Quantum ESPRESSO is an integrated suite of computer codes for electronic-structure calculations and materials modeling, based on density-functional theory, plane waves, and pseudopotentials (norm-conserving, ultrasoft, and projector-augmented wave). Quantum ESPRESSO stands for "opEn Source Package for Research in Electronic Structure, Simulation, and Optimization". It is freely available to researchers around the world under the terms of the GNU General Public License. Quantum ESPRESSO builds upon newly-restructured electronic-structure codes that have been developed and tested by some of the original authors of novel electronic-structure algorithms and applied in the last twenty years by some of the leading materials modeling groups worldwide. Innovation and efficiency are still its main focus, with special attention paid to massively-parallel architectures, and a great effort being devoted to user friendliness. Quantum ESPRESSO is evolving towards a distribution of independent and inter-operable codes in the spirit of an open-source project, where researchers active in the field of electronic-structure calculations are encouraged to participate in the project by contributing their own codes or by implementing their own ideas into existing codes.Comment: 36 pages, 5 figures, resubmitted to J.Phys.: Condens. Matte

    Gravitational Waves From Known Pulsars: Results From The Initial Detector Era

    Get PDF
    We present the results of searches for gravitational waves from a large selection of pulsars using data from the most recent science runs (S6, VSR2 and VSR4) of the initial generation of interferometric gravitational wave detectors LIGO (Laser Interferometric Gravitational-wave Observatory) and Virgo. We do not see evidence for gravitational wave emission from any of the targeted sources but produce upper limits on the emission amplitude. We highlight the results from seven young pulsars with large spin-down luminosities. We reach within a factor of five of the canonical spin-down limit for all seven of these, whilst for the Crab and Vela pulsars we further surpass their spin-down limits. We present new or updated limits for 172 other pulsars (including both young and millisecond pulsars). Now that the detectors are undergoing major upgrades, and, for completeness, we bring together all of the most up-to-date results from all pulsars searched for during the operations of the first-generation LIGO, Virgo and GEO600 detectors. This gives a total of 195 pulsars including the most recent results described in this paper.United States National Science FoundationScience and Technology Facilities Council of the United KingdomMax-Planck-SocietyState of Niedersachsen/GermanyAustralian Research CouncilInternational Science Linkages program of the Commonwealth of AustraliaCouncil of Scientific and Industrial Research of IndiaIstituto Nazionale di Fisica Nucleare of ItalySpanish Ministerio de Economia y CompetitividadConselleria d'Economia Hisenda i Innovacio of the Govern de les Illes BalearsNetherlands Organisation for Scientific ResearchPolish Ministry of Science and Higher EducationFOCUS Programme of Foundation for Polish ScienceRoyal SocietyScottish Funding CouncilScottish Universities Physics AllianceNational Aeronautics and Space AdministrationOTKA of HungaryLyon Institute of Origins (LIO)National Research Foundation of KoreaIndustry CanadaProvince of Ontario through the Ministry of Economic Development and InnovationNational Science and Engineering Research Council CanadaCarnegie TrustLeverhulme TrustDavid and Lucile Packard FoundationResearch CorporationAlfred P. Sloan FoundationAstronom

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns
    corecore