567 research outputs found
Treatment of Selective Mutism: Focus on Selective Serotonin Reuptake Inhibitors
Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/90271/1/phco.28.2.214.pd
Inguinal hernia surgery in the Netherlands: are patients treated according to the guidelines?
Purpose In 2003, a dedicated Dutch committee developed vidence-based guidelines for the treatment of nguinal hernia (IH) in children and adults. The aim of this tudy was to describe trends in hernia care before and after he publication of the guidelines on IH surgery in the etherlands. ethods Originally, a retrospective baseline analysis of H surgery in 90 Dutch hospitals was performed among atients treated for IH in 2001. The results of this baseline nalysis were compared with a recently performed second nalysis of patients treated for IH in 2005. esults In children\\4 years of age, the study showed a ignificant decrease of contralateral explorations. In adults, he study showed that significantly more patients were reated with a mesh-based repair in 2005 (95.9 vs. 78.8%, <0.01eover, there was an increase of patients ith bilateral hernia treated with an endoscopic technique 41.5 vs. 22.3%, P<0.01) and more patients were treated n day surgery (53.5 vs. 38.6%, P<0.01). Lastly, a decline n operations performed for recurrent IH in adults was bserved (10.9 vs. 13.3%, P<0.01). onclusion This study showed that most patients with IH n the Netherlands were treated according to the main ecommendations of the Dutch evidence-based guidelines
Sprint interval and sprint continuous training increases circulating CD34+ cells and cardio-respiratory fitness in young healthy women
The improvement of vascular health in the exercising limb can be attained by sprint interval training (SIT).
However, the effects on systemic vascular function and on circulating angiogenic cells (CACs) which may contribute to endothelial repair have not been investigated. Additionally, a comparison between SIT and sprint continuous training (SCT) which is less time committing has not been made
Scaling properties of protein family phylogenies
One of the classical questions in evolutionary biology is how evolutionary
processes are coupled at the gene and species level. With this motivation, we
compare the topological properties (mainly the depth scaling, as a
characterization of balance) of a large set of protein phylogenies with a set
of species phylogenies. The comparative analysis shows that both sets of
phylogenies share remarkably similar scaling behavior, suggesting the
universality of branching rules and of the evolutionary processes that drive
biological diversification from gene to species level. In order to explain such
generality, we propose a simple model which allows us to estimate the
proportion of evolvability/robustness needed to approximate the scaling
behavior observed in the phylogenies, highlighting the relevance of the
robustness of a biological system (species or protein) in the scaling
properties of the phylogenetic trees. Thus, the rules that govern the
incapability of a biological system to diversify are equally relevant both at
the gene and at the species level.Comment: Replaced with final published versio
Association of mitral annulus calcification, aortic valve calcification with carotid intima media thickness
BACKGROUND: Mitral annular calcification (MAC) and aortic annular calcification (AVC) may represent a manifestation of generalized atherosclerosis in the elederly. Alterations in vascular structure, as indexed by the intima media thickness (IMT), are also recognized as independent predictors of adverse cardiovascular outcomes. AIM: To examine the relationship between the degree of calcification at mitral and/or aortic valve annulus and large artery structure (thickness). METHODS: We evaluated 102 consecutive patients who underwent transthoracic echocardiography and carotid artery echoDoppler for various indications; variables measured were: systemic blood pressure (BP), pulse pressure (PP=SBP-DBP), body mass index (BMI), fasting glucose, total, HDL, LDL chlolesterol, triglycerides, cIMT. The patients were divided according to a grading of valvular/annular lesions independent scores based on acoustic densitometry: 1 = annular/valvular sclerosis/calcification absence; 2 = annular/valvular sclerosis; 3 = annular calcification; 4 = annular-valvular calcification; 5 = valvular calcification with no recognition of the leaflets. RESULTS: Patient score was the highest observed for either valvular/annulus. Mean cIMT increased linearly with increasing valvular calcification score, ranging from 3.9 ± 0.48 mm in controls to 12.9 ± 1.8 mm in those subjects scored 5 (p < 0.0001). In the first to fourth quartile of cIMT values the respective maximal percentual of score were: score 1: 76.1%, score 2: 70.1%, score 4: 54.3% and score 5: 69.5% (p > 0.0001). CONCLUSION: MAC and AVC score can identify subgroups of patients with different cIMT values which indicate different incidence and prevalence of systemic artery diseases. This data may confirm MAC-AVC as a useful important diagnostic parameter of systemic atherosclerotic disease
Infant head growth in male siblings of children with and without autism spectrum disorders
Previous research has indicated that children with autism exhibit accelerated head growth (HG) in infancy, although the timing of acceleration varies between studies. We examined infant HG trajectory as a candidate autism endophenotype by studying sibling pairs. We retrospectively obtained serial head orbitofrontal circumference measurements of: a) 48 sibling pairs in which one (n = 28) or both (n = 20) sibs were affected by an autism spectrum disorder (ASD); and b) 85 control male sibling pairs. Rate of HG of ASD subjects was slightly accelerated compared to controls, but the magnitude of difference was below the limit of reliability of standard measurement methods. Sibling intra class correlation for rate of HG was highly statistically significant; the magnitude was significantly stronger among autism-affected families (ICC = .63) than among controls (ICC = .26), p < .01. Infant HG trajectory appears familial—possibly endophenotypic—but was not a reliable marker of autism risk among siblings of ASD probands in this sample
Neural Computation via Neural Geometry: A Place Code for Inter-whisker Timing in the Barrel Cortex?
The place theory proposed by Jeffress (1948) is still the dominant model of how the brain represents the movement of sensory stimuli between sensory receptors. According to the place theory, delays in signalling between neurons, dependent on the distances between them, compensate for time differences in the stimulation of sensory receptors. Hence the location of neurons, activated by the coincident arrival of multiple signals, reports the stimulus movement velocity. Despite its generality, most evidence for the place theory has been provided by studies of the auditory system of auditory specialists like the barn owl, but in the study of mammalian auditory systems the evidence is inconclusive. We ask to what extent the somatosensory systems of tactile specialists like rats and mice use distance dependent delays between neurons to compute the motion of tactile stimuli between the facial whiskers (or ‘vibrissae’). We present a model in which synaptic inputs evoked by whisker deflections arrive at neurons in layer 2/3 (L2/3) somatosensory ‘barrel’ cortex at different times. The timing of synaptic inputs to each neuron depends on its location relative to sources of input in layer 4 (L4) that represent stimulation of each whisker. Constrained by the geometry and timing of projections from L4 to L2/3, the model can account for a range of experimentally measured responses to two-whisker stimuli. Consistent with that data, responses of model neurons located between the barrels to paired stimulation of two whiskers are greater than the sum of the responses to either whisker input alone. The model predicts that for neurons located closer to either barrel these supralinear responses are tuned for longer inter-whisker stimulation intervals, yielding a topographic map for the inter-whisker deflection interval across the surface of L2/3. This map constitutes a neural place code for the relative timing of sensory stimuli
Systematic review and meta-analysis of the diagnostic accuracy of ultrasonography for deep vein thrombosis
Background
Ultrasound (US) has largely replaced contrast venography as the definitive diagnostic test for deep vein thrombosis (DVT). We aimed to derive a definitive estimate of the diagnostic accuracy of US for clinically suspected DVT and identify study-level factors that might predict accuracy.
Methods
We undertook a systematic review, meta-analysis and meta-regression of diagnostic cohort studies that compared US to contrast venography in patients with suspected DVT. We searched Medline, EMBASE, CINAHL, Web of Science, Cochrane Database of Systematic Reviews, Cochrane Controlled Trials Register, Database of Reviews of Effectiveness, the ACP Journal Club, and citation lists (1966 to April 2004). Random effects meta-analysis was used to derive pooled estimates of sensitivity and specificity. Random effects meta-regression was used to identify study-level covariates that predicted diagnostic performance.
Results
We identified 100 cohorts comparing US to venography in patients with suspected DVT. Overall sensitivity for proximal DVT (95% confidence interval) was 94.2% (93.2 to 95.0), for distal DVT was 63.5% (59.8 to 67.0), and specificity was 93.8% (93.1 to 94.4). Duplex US had pooled sensitivity of 96.5% (95.1 to 97.6) for proximal DVT, 71.2% (64.6 to 77.2) for distal DVT and specificity of 94.0% (92.8 to 95.1). Triplex US had pooled sensitivity of 96.4% (94.4 to 97.1%) for proximal DVT, 75.2% (67.7 to 81.6) for distal DVT and specificity of 94.3% (92.5 to 95.8). Compression US alone had pooled sensitivity of 93.8 % (92.0 to 95.3%) for proximal DVT, 56.8% (49.0 to 66.4) for distal DVT and specificity of 97.8% (97.0 to 98.4). Sensitivity was higher in more recently published studies and in cohorts with higher prevalence of DVT and more proximal DVT, and was lower in cohorts that reported interpretation by a radiologist. Specificity was higher in cohorts that excluded patients with previous DVT. No studies were identified that compared repeat US to venography in all patients. Repeat US appears to have a positive yield of 1.3%, with 89% of these being confirmed by venography.
Conclusion
Combined colour-doppler US techniques have optimal sensitivity, while compression US has optimal specificity for DVT. However, all estimates are subject to substantial unexplained heterogeneity. The role of repeat scanning is very uncertain and based upon limited data
- …