106 research outputs found

    Anatomical and functional results of ossiculoplasty using titanium prosthesis

    Get PDF
    Titanium ossicular chain replacement prosthesis is often used for rehabilitation of the columellar effect in otologic surgeries. This retrospective study aims to analyse the anatomical and functional results of surgeries in which a titanium prosthesis was used. Two hundred and eighty procedures in 256 patients operated on in a tertiary referral center were analysed. Aetiologies, preoperative audiograms, peropera-tive data and postoperative outcomes at 2 and 12 months postoperatively were reviewed. Chronic suppurative otitis media with or without cholesteatoma was the main aetiology (89%). There was no difference in anatomical results between partial and total ossicular replacement prosthesis, with an overall dislocation rate of 6%, and an overall extrusion rate of 3%. Regarding functional results, a postoperative air-bone gap ≤ 20 dB was achieved in 65% of cases, with a better result for partial compared to total ossiculoplasty (p = 0.02). A significant difference in air bone gap closure was found when comparing aetiologies, with a higher air-bone gap closure in malformation cases compared to chronic suppurative otitis media with cholesteatoma or retraction cases (p = 0.03). Ossiculoplasty using titanium prosthesis is a safe and effective procedure for rehabilitation of hearing loss, which allows reaching an air-bone gap ≤ 20 dB in the majority of patients

    Surgical treatment of sporadic vestibular schwannoma in a series of 1006 patients = Trattamento chirurgico degli schwannomi vestibolari: Risultati su una serie di 1006 pazienti

    Get PDF
    The management of sporadic vestibular schwannoma (VS) has evolved in the last decades. The aim of this study was to analyse the evolution in surgical outcomes of VSs operated by a neurotological team between 1990 and 2006 by different approaches. A monocentric retrospective review of medical charts of 1006 patients was performed. In order to assess eventual changes and progress, the 17-years period was divided in three periods, each one comprehending 268 VS (1990-1996), 299 VS (1997-2001), and 439 VS (2002-2006). Mean follow-up was 5.9 ± 2.4 years. Overall, complete VS removal was achieved in 99.4% of cases. Mortality rate was 0.3%, meningitis and CSF leaks were observed in 1.2 % and 9 % of the cases, respectively. CSF leakage decreased from 11.6% to 7.1% between the first and last period (p < 0.01) as well as revision surgery from 3.4 % to 0.9 % (p < 0.05). Facial nerve was anatomically preserved in 97.7% of cases. At one year, a good facial nerve function was observed in 85.1% of patients (grade I and II of House-Brackmann grading scale), which ranged between the first and last period from 78.4% to 87.6% (p <0.05). At one year, hearing preservation was obtained in 61.6% of patients, which increased from the first period to the last one from 50.9% to 69.0% (p < 0.05) (class A+B+C from the AAO-HNS classification). Useful hearing (class A+B) was observed in 33.5% of cases overall, with 21.8% and 42% in the first and last period, respectively (p < 0.01). Surgical outcomes of sporadic vestibular schwannoma have improved concerning facial nerve function outcomes, hearing preservation and cerebrospinal fluid (CSF) leaks, mainly due to the neuro-otological team’s experience. Functional results after complete microsurgical removal of large VS depend on experience gained on small VS removal

    3D curved multiplanar cone beam CT reconstruction for intracochlear position assessment of straight electrodes array. A temporal bones and patients study

    Get PDF
    A retrospective review of post-op cone beam CT (CBCT) of 8 adult patients and 14 fresh temporal bones that underwent cochlear implantation with straight flexible electrodes array was performed to determine if the position of a long and flexible electrodes array within the cochlear scalae could be reliably assessed with CBCT. An oto-radiologist and two otologists examined the images and assessed the electrodes position. The temporal bone specimens underwent histological analysis for confirm the exact position. The position of the electrodes was rated as scala tympani, scala vestibule, or intermediate position for the electrodes at 180°, 360° and for the apical electrode. In the patient group, for the electrodes at 180° all observers agreed for scala tympani position except for 1 evaluation, while a discrepancy in 3 patients both for the 360° and for the apical electrode assessment were found. In five temporal bones the evaluations were in discrepancy for the 180° electrode, while at 360° a disagreement between raters on the scalar positioning was seen in six temporal bones. A higher discrepancy between was found in assessment of the scalar position of the apical electrode (average pairwise agreement 45.4%, Fleiss k = 0.13). A good concordance was found between the histological results and the consensus between raters for the electrodes in the basal turn, while low agreement (Cohen’s k 0.31, pairwise agreement 50%) was found in the identification of the apical electrode position confirming the difficulty to correct identify the electrode position in the second cochlear turn in temporal bones. In conclusion, CBCT is a reliable radiologic exam to correctly evaluate the position of a lateral wall flexible array in implanted patients using the proposed imaging reconstruction method, while some artefacts impede exact evaluation of the position of the apical electrode in temporal bone and other radiological techniques should be preferred in ex vivo studies

    ACTA OTORHINOLARYNGOLOGICA ITALICA

    Get PDF
    La gestione dello schwannoma vestibolare (SV) sporadico si è gradualmente evoluta negli ultimi decenni. Lo scopo di questo studio è di analizzare levoluzione negli esiti chirurgici dellexeresi di queste lesioni, realizzata da un team neurotologico tra il 1990 e il 2006, attraverso differenti approcci. È stata eseguita una revisione retrospettica monocentrica dei dati clinici di 1006 pazienti. Al fine di valutare eventuali modifiche e progressi, il periodo di 17 anni è stato diviso in tre periodi, ciascuno comprendente rispettivamente 268 SV (1990- 1996), 299 SV (1997-2001), e 439 SV (2002-2006). Il follow-up medio è stato di 5,9 ± 2,4 anni. Complessivamente lasportazione totale è stata ottenuta nel 99,4% dei casi. Il tasso di mortalità è stato dello 0,3%, la meningite e la perdita di liquido cefalo rachidiano (LCR) sono stati osservati nel 1,2% e il 9% dei casi, rispettivamente. La frequenza della perdita di LCR è diminuita dal 11,6% al 7,1% tra il primo e dellultimo periodo (p < 0,01) e la revisione chirurgica dal 3,4% al 0,9% (p < 0,05). Il nervo facciale è stato anatomicamente conservato nel 97,7% dei casi. Ad un anno, una buona funzione del nervo facciale è stata osservata nel 85,1% dei pazienti (I e II grado House- Brackmann), con una variazione tra il primo e lultimo periodo che andava dal 78,4% al 87,6% (p < 0,05). Ad un anno post-operatorio la conservazione delludito è stata ottenuta nel 61,6% dei pazienti, passando dal 50,9% del primo periodo, al 69,0% del periodo piú recente (p < 0,05) (classe A + B + C dalla classificazione AAO-HNS). Ludito utile (classe A + B) è stato conservato nel 33,5% dei casi complessivamente, con percentuali comprese tra il 21,8% e 42% nel primo e nellultimo periodo rispettivamente (p < 0,01). Gli esiti chirurgici dellasportazion dello schwannoma vestibolare sporadico sono migliorati negli anni per quanto riguarda i risultati funzionali del nervo facciale, la conservazione delludito, le perdite di liquido cefalorachidiano, principalmente grazie allesperienza del team neurotologico. I risultati funzionali dopo la rimozione microchirurgica completa SV di grandi dimensioni dipendono dall esperienza maturata sulle lesioni di piccole dimensioni

    PMS53 Association Between Teriparatide Adherence and Health Care Utilization and Costs in Real World United States Kyphoplasty/Vertebroplasty Patients

    Get PDF
    The Gulf of Follonica (Italy) is impacted by the chemical pollution from ancient mining activity and present industrial processes. This study was aimed to determine the bioavailability of dioxin-like compounds (DLCs) in coastal marine environment and to assess the genotoxic potential of waste waters entering the sea from an industrial canal. Moderately high levels of DCLs compounds ( 11 PCDDs + PCDFs 2.18\u201329.00 pg/g dry wt) were detected in Mytilus galloprovincialis transplanted near the waste waters canal and their corresponding Toxic Equivalents (TEQs) calculated. In situ exposed mussels did not show any genotoxic effect (by Comet and Micronucleus assay). Otherwise, laboratory exposure to canal waters exhibited a reduced genomic template stability (by RAPD-PCR assay) but not DNA or chromosomal damage. Our data reveal the need to focus on the levels and distribution of DLCs in edible species from the study area considering their potential transfer to humans through the consumption of sea food

    Ricostruzione multiplanare 3D di immagini cone beam per lidenficazione della posizione degli impianti cocleari. Studio su ossi temporali e pazienti impiantati

    Get PDF
    Questo studio riporta unanalisi retrospettica delle immagini cone beam CT effettuate su 8 pazienti adulti sottoposti ad impianto cochleare MedEl flex 28 e su 14 ossi temporali impiantati con lo stesso tipo di array portaelettrodi. Lo scopo dello studio é di determinare laffidabilità della metodica cone beam CT nella valutazione della posizione intracocleare degli elettrodi in impianti che si posizionano lungo la parete laterale del lume cocleare, quindi non perimodiolari la cui posizione é più facilmente identificabile. Un otoradiologo e due otologi hanno analizzato le immagini e assegnato la posizione per ciascun elettrodo localizzato nella regione dei 180° e dei 360° del primo giro cocleare e per lelettrodo apicale scegliendo tra scala timpanica, vestibulare o posizione intermedia Lanalisi istologica ha successivamente confermato lesatta posizione negli ossi temporali. Nel gruppo dei pazienti per lelettrodo a 180° i tre esperti concordavano sulla posizione in scala timpanica in tutti eccetto un paziente, mentre una discordanza nella valutazione era presente in 3 pazienti per gli elettrodi a 360° e per gli elettrodi apicali. Negli ossi temporali in 5 casi era presente una discordanza per lelettrodo a 180°, mentre a 360° sei valutazioni erano discordanti tra i valutatori. Una disdcordanza tra le valutazioni più elevata veniva trovata per la la posizione dellelettrodo apicale (concordanza valutatori 45.4%, Fleiss k = 0,13). Un buon grado di concordanza veniva trovato tra i risultati istologici e le valutazioni tra i valutatori per gli elettrodi localizzati nel giro basale; un grado più basso esisteva per la posizione degli elettrodi apicali (concordanza valutatori 50%, Cohens k = 0,31) confermando la difficoltà nella corretta valutazione della posizione degli elettrodi nella regione più apicale negli ossi temporali. In conclusione, le immagini cone beam postoperatorie analizzate con la metodica della ricostruzione multiplanare 3D rappresentano una metodica affidabile per lo studio della posizione intracocleare degli elettrodi a posizionamento laterale nei pazienti impiantati. La corretta identificazione del posizionamento dellelettrodo piu apicale risulta difficile su osso temporale per la presenza di un artefatto più importante o per la minore resistenza delle strutture della parete laterale della coclea (legamento spirale, membrane basilare) nel preparato istologico (osso temporale fresco/congelato) che è responsabile di un maggior numero di traslocazioni dalla rampa timpanica alla rampa vestibolare e di localizzazioni intermedie più difficilmente interpretabili

    The future of Cybersecurity in Italy: Strategic focus area

    Get PDF
    This volume has been created as a continuation of the previous one, with the aim of outlining a set of focus areas and actions that the Italian Nation research community considers essential. The book touches many aspects of cyber security, ranging from the definition of the infrastructure and controls needed to organize cyberdefence to the actions and technologies to be developed to be better protected, from the identification of the main technologies to be defended to the proposal of a set of horizontal actions for training, awareness raising, and risk management

    Design-time formal verification for smart environments: an exploratory perspective

    Get PDF
    Smart environments (SmE) are richly integrated with multiple heterogeneous devices; they perform the operations in intelligent manner by considering the context and actions/behaviors of the users. Their major objective is to enable the environment to provide ease and comfort to the users. The reliance on these systems demands consistent behavior. The versatility of devices, user behavior and intricacy of communication complicate the modeling and verification of SmE's reliable behavior. Of the many available modeling and verification techniques, formal methods appear to be the most promising. Due to a large variety of implementation scenarios and support for conditional behavior/processing, the concept of SmE is applicable to diverse areas which calls for focused research. As a result, a number of modeling and verification techniques have been made available for designers. This paper explores and puts into perspective the modeling and verification techniques based on an extended literature survey. These techniques mainly focus on some specific aspects, with a few overlapping scenarios (such as user interaction, devices interaction and control, context awareness, etc.), which were of the interest to the researchers based on their specialized competencies. The techniques are categorized on the basis of various factors and formalisms considered for the modeling and verification and later analyzed. The results show that no surveyed technique maintains a holistic perspective; each technique is used for the modeling and verification of specific SmE aspects. The results further help the designers select appropriate modeling and verification techniques under given requirements and stress for more R&D effort into SmE modeling and verification researc

    Genotoxicity of metal oxide nanomaterials: review of recent data and discussion of possible mechanisms

    Get PDF
    Nanotechnology has rapidly entered into human society, revolutionized many areas, including technology, medicine and cosmetics. This progress is due to the many valuable and unique properties that nanomaterials possess. In turn, these properties might become an issue of concern when considering potentially uncontrolled release to the environment. The rapid development of new nanomaterials thus raises questions about their impact on the environment and human health. This review focuses on the potential of nanomaterials to cause genotoxicity and summarizes recent genotoxicity studies on metal oxide/silica nanomaterials. Though the number of genotoxicity studies on metal oxide/silica nanomaterials is still limited, this endpoint has recently received more attention for nanomaterials, and the number of related publications has increased. An analysis of these peer reviewed publications over nearly two decades shows that the test most employed to evaluate the genotoxicity of these nanomaterials is the comet assay, followed by micronucleus, Ames and chromosome aberration tests. Based on the data studied, we concluded that in the majority of the publications analysed in this review, the metal oxide (or silica) nanoparticles of the same core chemical composition did not show different genotoxicity study calls (i.e. positive or negative) in the same test, although some results are inconsistent and need to be confirmed by additional experiments. Where the results are conflicting, it may be due to the following reasons: (1) variation in size of the nanoparticles; (2) variations in size distribution; (3) various purities of nanomaterials; (4) variation in surface areas for nanomaterials with the same average size; (5) differences in coatings; (6) differences in crystal structures of the same types of nanomaterials; (7) differences in size of aggregates in solution/media; (8) differences in assays; (9) different concentrations of nanomaterials in assay tests. Indeed, due to the observed inconsistencies in the recent literature and the lack of adherence to appropriate, standardized test methods, reliable genotoxicity assessment of nanomaterials is still challenging
    corecore