645 research outputs found
Gravitational Instantons and Fluxes from M/F-theory on Calabi-Yau fourfolds
We compactify four-dimensional N=1 gauged supergravity theories on a circle
including fluxes for shift-symmetric scalars. Four-dimensional Taub-NUT
gravitational instantons universally correct the three-dimensional
superpotential in the absence of fluxes. In the presence of fluxes these
Taub-NUT instanton contributions are no longer gauge-invariant. Invariance can
be restored by gauge instantons on top of Taub-NUT instantons. We establish the
embedding of this scenario into M-theory. Circle fluxes and gaugings arise from
a restricted class of M-theory four-form fluxes on a resolved Calabi-Yau
fourfold. The M5-brane on the base of the elliptic fourfold dualizes into the
universal Taub-NUT instanton. In the presence of fluxes this M5-brane is
anomalous. We argue that anomaly free contributions arise from involved
M5-brane geometries dual to gauge-instantons on top of Taub-NUT instantons.
Adding a four-dimensional superpotential to the gravitational instanton
corrections leads to three-dimensional Anti-de Sitter vacua at stabilized
compactification radius. We comment on the possibility to uplift these M-theory
vacua, and to tunnel to four-dimensional F-theory vacua.Comment: 47 pages, 2 figure
Predicting the risk of malignancy in adnexal masses based on the Simple Rules from the International Ovarian Tumor Analysis group
BACKGROUND: Accurate methods to preoperatively characterize adnexal tumors are pivotal for optimal patient management. A recent metaanalysis concluded that the International Ovarian Tumor Analysis algorithms such as the Simple Rules are the best approaches to preoperatively classify adnexal masses as benign or malignant. OBJECTIVE: We sought to develop and validate a model to predict the risk of malignancy in adnexal masses using the ultrasound features in the Simple Rules. STUDY DESIGN: This was an international cross-sectional cohort study involving 22 oncology centers, referral centers for ultrasonography, and general hospitals. We included consecutive patients with an adnexal tumor who underwent a standardized transvaginal ultrasound examination and were selected for surgery. Data on 5020 patients were recorded in 3 phases from 2002 through 2012. The 5 Simple Rules features indicative of a benign tumor (B-features) and the 5 features indicative of malignancy (M-features) are based on the presence of ascites, tumor morphology, and degree of vascularity at ultrasonography. Gold standard was the histopathologic diagnosis of the adnexal mass (pathologist blinded to ultrasound findings). Logistic regression analysis was used to estimate the risk of malignancy based on the 10 ultrasound features and type of center. The diagnostic performance was evaluated by area under the receiver operating characteristic curve, sensitivity, specificity, positive likelihood ratio (LR+), negative likelihood ratio (LR-), positive predictive value (PPV), negative predictive value (NPV), and calibration curves. RESULTS: Data on 4848 patients were analyzed. The malignancy rate was 43% (1402/3263) in oncology centers and 17% (263/1585) in other centers. The area under the receiver operating characteristic curve on validation data was very similar in oncology centers (0.917; 95% confidence interval, 0.901-0.931) and other centers (0.916; 95% confidence interval, 0.873-0.945). Risk estimates showed good calibration. In all, 23% of patients in the validation data set had a very low estimated risk (<1%) and 48% had a high estimated risk (≥30%). For the 1% risk cutoff, sensitivity was 99.7%, specificity 33.7%, LR+ 1.5, LR- 0.010, PPV 44.8%, and NPV 98.9%. For the 30% risk cutoff, sensitivity was 89.0%, specificity 84.7%, LR+ 5.8, LR- 0.13, PPV 75.4%, and NPV 93.9%. CONCLUSION: Quantification of the risk of malignancy based on the Simple Rules has good diagnostic performance both in oncology centers and other centers. A simple classification based on these risk estimates may form the basis of a clinical management system. Patients with a high risk may benefit from surgery by a gynecological oncologist, while patients with a lower risk may be managed locally
Strategies to diagnose ovarian cancer: new evidence from phase 3 of the multicentre international IOTA study
Background: To compare different ultrasound-based international ovarian tumour analysis (IOTA) strategies and risk of malignancy index (RMI) for ovarian cancer diagnosis using a meta-analysis approach of centre-specific data from IOTA3. Methods: This prospective multicentre diagnostic accuracy study included 2403 patients with 1423 benign and 980 malignant adnexal masses from 2009 until 2012. All patients underwent standardised transvaginal ultrasonography. Test performance of RMI, subjective assessment (SA) of ultrasound findings, two IOTA risk models (LR1 and LR2), and strategies involving combinations of IOTA simple rules (SRs), simple descriptors (SDs) and LR2 with and without SA was estimated using a meta-analysis approach. Reference standard was histology after surgery. Results: The areas under the receiver operator characteristic curves of LR1, LR2, SA and RMI were 0.930 (0.917–0.942), 0.918 (0.905–0.930), 0.914 (0.886–0.936) and 0.875 (0.853–0.894). Diagnostic one-step and two-step strategies using LR1, LR2, SR and SD achieved summary estimates for sensitivity 90–96%, specificity 74–79% and diagnostic odds ratio (DOR) 32.8–50.5. Adding SA when IOTA methods yielded equivocal results improved performance (DOR 57.6–75.7). Risk of Malignancy Index had sensitivity 67%, specificity 91% and DOR 17.5. Conclusions: This study shows all IOTA strategies had excellent diagnostic performance in comparison with RMI. The IOTA strategy chosen may be determined by clinical preference
Boundary Layer Heat Transport Experiments in Alcator C-Mod in Support of the FY2010 US DoE Joint Research Target
Accurate path integration in continuous attractor network models of grid cells
Grid cells in the rat entorhinal cortex display strikingly regular firing responses to the animal's position in 2-D space and have been hypothesized to form the neural substrate for dead-reckoning. However, errors accumulate rapidly when velocity inputs are integrated in existing models of grid cell activity. To produce grid-cell-like responses, these models would require frequent resets triggered by external sensory cues. Such inadequacies, shared by various models, cast doubt on the dead-reckoning potential of the grid cell system. Here we focus on the question of accurate path integration, specifically in continuous attractor models of grid cell activity. We show, in contrast to previous models, that continuous attractor models can generate regular triangular grid responses, based on inputs that encode only the rat's velocity and heading direction. We consider the role of the network boundary in the integration performance of the network and show that both periodic and aperiodic networks are capable of accurate path integration, despite important differences in their attractor manifolds. We quantify the rate at which errors in the velocity integration accumulate as a function of network size and intrinsic noise within the network. With a plausible range of parameters and the inclusion of spike variability, our model networks can accurately integrate velocity inputs over a maximum of ~10–100 meters and ~1–10 minutes. These findings form a proof-of-concept that continuous attractor dynamics may underlie velocity integration in the dorsolateral medial entorhinal cortex. The simulations also generate pertinent upper bounds on the accuracy of integration that may be achieved by continuous attractor dynamics in the grid cell network. We suggest experiments to test the continuous attractor model and differentiate it from models in which single cells establish their responses independently of each other
Cumulative Prognostic Score Predicting Mortality in Patients Older Than 80 Years Admitted to the ICU.
OBJECTIVES: To develop a scoring system model that predicts mortality within 30 days of admission of patients older than 80 years admitted to intensive care units (ICUs). DESIGN: Prospective cohort study. SETTING: A total of 306 ICUs from 24 European countries. PARTICIPANTS: Older adults admitted to European ICUs (N = 3730; median age = 84 years [interquartile range = 81-87 y]; 51.8% male). MEASUREMENTS: Overall, 24 variables available during ICU admission were included as potential predictive variables. Multivariable logistic regression was used to identify independent predictors of 30-day mortality. Model sensitivity, specificity, and accuracy were evaluated with receiver operating characteristic curves. RESULTS: The 30-day-mortality was 1562 (41.9%). In multivariable analysis, these variables were selected as independent predictors of mortality: age, sex, ICU admission diagnosis, Clinical Frailty Scale, Sequential Organ Failure Score, invasive mechanical ventilation, and renal replacement therapy. The discrimination, accuracy, and calibration of the model were good: the area under the curve for a score of 10 or higher was .80, and the Brier score was .18. At a cut point of 10 or higher (75% of all patients), the model predicts 30-day mortality in 91.1% of all patients who die. CONCLUSION: A predictive model of cumulative events predicts 30-day mortality in patients older than 80 years admitted to ICUs. Future studies should include other potential predictor variables including functional status, presence of advance care plans, and assessment of each patient's decision-making capacity
Winter to spring variations of chromophoric dissolved organic matter in a temperate estuary (Po river, Northern Adriatic Sea)
Taking the long view on short-run marginal emissions: how much carbon does flexibility and energy storage save?
Data availability statement: The data underlying this article is available on request from the corresponding author.Copyright © The Author(s) 2023. Grid-scale electricity storage will play a crucial role in the transition of power systems towards zero carbon. During the transition, investments need to be channeled towards technologies and locations that enable zero carbon operation in the long term, while also delivering security of supply and value for money. We discuss metrics and market signals that are needed to guide this transition towards clean, secure and affordable solutions. Paradoxically, carbon metrics play an important role, but become less effective as a decision tool once the system approaches zero carbon. We critically assess the role of marginal and average emission and question the allocation of marginal emissions in systems where combinations of renewables and storage deliver flexibility. We conclude that, for strategic investments, short-term market signals may not always deliver sufficiently fast or far-sighted outcomes and operational decisions need to consider the merit order of demand as well as supply.UKRI Prospering from the Energy Revolution’s Energy Superhub Oxford demonstrator and ‘Data-driven exploration of the carbon emissions impact of grid energy storage deployment and dispatch’ (DIGEST EP/W027321/1)
OC152: Prevalence of cancer and optimal cut‐off levels for mathematical models to distinguish between benign and malignant adnexal masses
n/
- …
