568 research outputs found

    A 5 Gb/s Radiation Tolerant Laser Driver

    Get PDF
    A laser driver for data transmission at 5 Gb/s has been developed as a part of the Giga Bit Transceiver (GBT) project. The Giga Bit Laser Driver (GBLD) targets High Energy Physics (HEP) applications for which radiation tolerance is mandatory. The GBLD ASIC can drive both VCSELs and some types of edge emitting lasers. It is essentially composed of two drivers capable of sinking up to 12 mA each from the load at a maximum data rate of 5 Gb/s, and of a current sink for the laser bias current. The laser driver include also pre-emphasis and duty cycle control capabilities

    Artificial intelligence for renal cancer: From imaging to histology and beyond

    Get PDF
    Artificial intelligence (AI) has made considerable progress within the last decade and is the subject of contemporary literature. This trend is driven by improved computational abilities and increasing amounts of complex data that allow for new approaches in analysis and interpretation. Renal cell carcinoma (RCC) has a rising incidence since most tumors are now detected at an earlier stage due to improved imaging. This creates considerable challenges as approximately 10%–17% of kidney tumors are designated as benign in histopathological evaluation; however, certain co-morbid populations (the obese and elderly) have an increased peri-interventional risk. AI offers an alternative solution by helping to optimize precision and guidance for diagnostic and therapeutic decisions. The narrative review introduced basic principles and provide a comprehensive overview of current AI techniques for RCC. Currently, AI applications can be found in any aspect of RCC management including diagnostics, perioperative care, pathology, and follow-up. Most commonly applied models include neural networks, random forest, support vector machines, and regression. However, for implementation in daily practice, health care providers need to develop a basic understanding and establish interdisciplinary collaborations in order to standardize datasets, define meaningful endpoints, and unify interpretation

    Silicon Mie Resonators for Highly Directional Light Emission from monolayer MoS2

    Get PDF
    Controlling light emission from quantum emitters has important applications ranging from solid-state lighting and displays to nanoscale single-photon sources. Optical antennas have emerged as promising tools to achieve such control right at the location of the emitter, without the need for bulky, external optics. Semiconductor nanoantennas are particularly practical for this purpose because simple geometries, such as wires and spheres, support multiple, degenerate optical resonances. Here, we start by modifying Mie scattering theory developed for plane wave illumination to describe scattering of dipole emission. We then use this theory and experiments to demonstrate several pathways to achieve control over the directionality, polarization state, and spectral emission that rely on a coherent coupling of an emitting dipole to optical resonances of a Si nanowire. A forward-to-backward ratio of 20 was demonstrated for the electric dipole emission at 680 nm from a monolayer MoS2 by optically coupling it to a Si nanowire

    Precise mirror alignment and basic performance of the RICH detector of the NA62 experiment at CERN

    Get PDF
    The Ring Imaging Cherenkov detector is crucial for the identification of charged particles in the NA62 experiment at the CERN SPS. The detector commissioning was completed in 2016 by the precise alignment of mirrors using reconstructed tracks. The alignment procedure and measurement of the basic performance are described. Ring radius resolution, ring centre resolution, single hit resolution and mean number of hits per ring are evaluated for positron tracks. The contribution of the residual mirror misalignment to the performance is calculated.Comment: 13 pages, 10 figure

    !CHAOS: A cloud of controls

    Get PDF
    The paper is aimed to present the !CHAOS open source project aimed to develop a prototype of a national private Cloud Computing infrastructure, devoted to accelerator control systems and large experiments of High Energy Physics (HEP). The !CHAOS project has been financed by MIUR (Italian Ministry of Research and Education) and aims to develop a new concept of control system and data acquisition framework by providing, with a high level of abstraction, all the services needed for controlling and managing a large scientific, or non-scientific, infrastructure. A beta version of the !CHAOS infrastructure will be released at the end of December 2015 and will run on private Cloud infrastructures based on OpenStack

    New Ultra-minimally Invasive Surgical Treatment for Benign Prostatic Hyperplasia: A Systematic Review and Analysis of Comparative Outcomes

    Get PDF
    Context: Benign prostatic hyperplasia (BPH) associated with lower urinary tract symptoms (LUTS) is diagnosed in up to 80% of men during their lifetime. Several novel ultra-minimally invasive surgical treatments (uMISTs) for BPH/benign prostatic obstruction (BPO) have become available over the past 5 yr. Objective: To evaluate the perioperative and functional outcomes of recently introduced uMISTs for BPH/BPO, including Urolift, Rezūm, temporary implantable nitinol device, prostatic artery embolization (PAE), and intraprostatic injection. Evidence acquisition: A systematic literature search was conducted in December 2020 using Medline (via PubMed), Embase (via Ovid), Scopus, and Web of Science (registered on PROSPERO as CRD42021225014). The search strategy used PICO criteria and article selection was conducted in accordance with the PRISMA guidelines. The risk of bias and the quality of the articles included were assessed. A dedicated data extraction form was used to collect the data of interest. Pooled and cumulative analyses were performed to compare perioperative and functional outcomes between study groups. A random-effects model using the DerSimonian and Laird method was used to evaluate heterogeneity. Stata version 15.0 software was used for all statistical analyses. Evidence synthesis: The initial electronic search identified 3978 papers, of which 48 ultimately met the inclusion criteria and were included in the analysis. Pooled analysis revealed a uMIST benefit in terms of International Prostate Symptom Score (IPSS; −9.81 points, 95% confidence interval [CI] −11.37 to −8.25 at 1 mo; −13.13 points, 95% CI −14.98 to −11.64 at 12 mo), maximum flow rate (from +3.66 ml/s, 95% CI 2.8–4.5 to +4.14 ml/s, 95% CI 0.72–7.56 at 12 mo), and postvoid residual volume (−10.10 ml, 95% CI −27.90 to 7.71 at 12 mo). No negative impact was observed on scores for the International Index of Erectile Function-5, Male Sexual Health Questionnaire-Ejaculatory Dysfunction bother and function scales (overall postintervention change in pooled median score of 1.88, 95% CI 1.34–2.42 at the start of follow-up; and 1.04, 95% CI 0.28–1.8 after 1 yr), or the IPSS-Quality of Life questionnaire. Conclusions: Novel uMISTs can yield fast and effective relief of LUTS without affecting patient quality of life. Only Rezūm, UroLift, and PAE had a minimal impact on patients’ sexual function with respect to baseline, especially regarding preservation of ejaculation. Patient summary: We reviewed outcomes for recently introduced ultra-minimally invasive surgical treatments for patients with lower urinary tract symptoms caused by benign prostate enlargement or obstruction. The evidence suggests that these novel techniques are beneficial in terms of controlling symptoms while preserving sexual function. Take Home Message: Novel ultra-minimally invasive treatments can yield fast and effective relief of lower urinary tract symptoms without affecting a patient's quality of life

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Performance and Operation of the CMS Electromagnetic Calorimeter

    Get PDF
    The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented
    corecore