19 research outputs found

    Spectroscopic Studies of Carbocyanine and 2,4,6- Trisubstituted Pyridine Dyes for Bioanalytical and pH Indicating Applications

    Get PDF
    In part A, the effect of varying short-chain alkyl substitution on the spectroscopic properties of cyanine dyes was examined. Molar absorptivities and quantum yields were determined for groups of pentamethine and heptamethine dyes for which the substitution of the indole nitrogen was varied. For both sets of dyes, increasing alkyl chain length did not significantly change quantum yield or molar absorptivity. These results may be useful in designing new cyanine dyes. In part B, the effect of structure on the suitability of 2,4,6-trisubstituted pyridines as color pH indicators was studied by determining spectral effects of protonation, molar absorptivities, pKa values, and the structural origin of the spectral behavior. Good color indicating properties result from aniline substitution at the 4 position of pyridine and electron donating substitution at the 2 and 6 positions of pyridine, which provide a strong red shift in the spectra and greater red shifted peak absorptivity, respectively

    Synthesis and Characterization of Fluorescent Silica Nanoparticles with Large Stokes Shifts for Multiplexed Assays and Imaging

    Get PDF
    Modern approaches to biological and biomedical analysis demand ever-increasing levels of sensitivity, selectivity, and throughput. This challenge has been addressed in the work described herein via the synthesis, characterization, and proofs of concept of a series of single and multidye copolymerized fluorescent silica nanoparticles with large Stokes shifts and near infrared fluorescence. The prepared fluorescent probes exhibit substantially enhanced fluorescence signals relative to their constituent dyes, good indicators of biocompatibility, and readily distinguishable fluorescence signals, promoting the simultaneous detection of multiple targets and reducing both the cost and time per assay. A novel NIR-fluorescent aminocyanine dye was designed for incorporation into silica nanoparticles, then synthesized and characterized as detailed in the second chapter. Spectroscopic characterization confirmed the intended dye structure and revealed a large Stokes shift, near infrared fluorescence, and a relatively high quantum yield, indicating the suitability of this compound for bioanalytical applications and incorporation into silica nanoparticles as either a standalone fluorophore or as a resonance energy transfer acceptor for other UV-visible dyes. In the third chapter, the incorporation of the novel dye and other commercial dyes into silica nanoparticles is discussed, along with characterization and proofs of concept for in vivo and in vitro applications of the resultant fluorescent labels. Nanoparticle synthetic approaches, dye concentrations, and surface coating densities were optimized for fluorescence intensities and biocompatibility. Nanoparticles containing single and multiple dye species were synthesized per the optimal parameters, producing a series of fluorescent tags with distinct fluorescence signatures and large Stokes shifts. Synthesized nanoparticles were characterized in terms of sizes, synthetic yields, quantum yields, limits of detection, stability, and synthetic reproducibility. The suitability of surface modified nanoparticles to in vitro and in vivo applications was demonstrated via biotin linkage to streptavidin microbeads and fluorescence microscopy imaging, hemocompatibility studies, and protein binding studies. Finally, in the fourth chapter, resonance energy transfer characteristics of multidye copolymerized nanoparticles were characterized. Energy transfer efficiencies between donor-acceptor pairs, numbers of dye molecules per nanoparticle, and average distances between dye molecules were calculated, then Förster radii for different donor-acceptor pairs were estimated using two approaches and compared

    Global economic burden of unmet surgical need for appendicitis

    Get PDF
    Background: There is a substantial gap in provision of adequate surgical care in many low-and middle-income countries. This study aimed to identify the economic burden of unmet surgical need for the common condition of appendicitis. Methods: Data on the incidence of appendicitis from 170 countries and two different approaches were used to estimate numbers of patients who do not receive surgery: as a fixed proportion of the total unmet surgical need per country (approach 1); and based on country income status (approach 2). Indirect costs with current levels of access and local quality, and those if quality were at the standards of high-income countries, were estimated. A human capital approach was applied, focusing on the economic burden resulting from premature death and absenteeism. Results: Excess mortality was 4185 per 100 000 cases of appendicitis using approach 1 and 3448 per 100 000 using approach 2. The economic burden of continuing current levels of access and local quality was US 92492millionusingapproach1and92 492 million using approach 1 and 73 141 million using approach 2. The economic burden of not providing surgical care to the standards of high-income countries was 95004millionusingapproach1and95 004 million using approach 1 and 75 666 million using approach 2. The largest share of these costs resulted from premature death (97.7 per cent) and lack of access (97.0 per cent) in contrast to lack of quality. Conclusion: For a comparatively non-complex emergency condition such as appendicitis, increasing access to care should be prioritized. Although improving quality of care should not be neglected, increasing provision of care at current standards could reduce societal costs substantially

    Pooled analysis of WHO Surgical Safety Checklist use and mortality after emergency laparotomy

    Get PDF
    Background The World Health Organization (WHO) Surgical Safety Checklist has fostered safe practice for 10 years, yet its place in emergency surgery has not been assessed on a global scale. The aim of this study was to evaluate reported checklist use in emergency settings and examine the relationship with perioperative mortality in patients who had emergency laparotomy. Methods In two multinational cohort studies, adults undergoing emergency laparotomy were compared with those having elective gastrointestinal surgery. Relationships between reported checklist use and mortality were determined using multivariable logistic regression and bootstrapped simulation. Results Of 12 296 patients included from 76 countries, 4843 underwent emergency laparotomy. After adjusting for patient and disease factors, checklist use before emergency laparotomy was more common in countries with a high Human Development Index (HDI) (2455 of 2741, 89.6 per cent) compared with that in countries with a middle (753 of 1242, 60.6 per cent; odds ratio (OR) 0.17, 95 per cent c.i. 0.14 to 0.21, P <0001) or low (363 of 860, 422 per cent; OR 008, 007 to 010, P <0.001) HDI. Checklist use was less common in elective surgery than for emergency laparotomy in high-HDI countries (risk difference -94 (95 per cent c.i. -11.9 to -6.9) per cent; P <0001), but the relationship was reversed in low-HDI countries (+121 (+7.0 to +173) per cent; P <0001). In multivariable models, checklist use was associated with a lower 30-day perioperative mortality (OR 0.60, 0.50 to 073; P <0.001). The greatest absolute benefit was seen for emergency surgery in low- and middle-HDI countries. Conclusion Checklist use in emergency laparotomy was associated with a significantly lower perioperative mortality rate. Checklist use in low-HDI countries was half that in high-HDI countries.Peer reviewe

    Intraperitoneal drain placement and outcomes after elective colorectal surgery: international matched, prospective, cohort study

    Get PDF
    Despite current guidelines, intraperitoneal drain placement after elective colorectal surgery remains widespread. Drains were not associated with earlier detection of intraperitoneal collections, but were associated with prolonged hospital stay and increased risk of surgical-site infections.Background Many surgeons routinely place intraperitoneal drains after elective colorectal surgery. However, enhanced recovery after surgery guidelines recommend against their routine use owing to a lack of clear clinical benefit. This study aimed to describe international variation in intraperitoneal drain placement and the safety of this practice. Methods COMPASS (COMPlicAted intra-abdominal collectionS after colorectal Surgery) was a prospective, international, cohort study which enrolled consecutive adults undergoing elective colorectal surgery (February to March 2020). The primary outcome was the rate of intraperitoneal drain placement. Secondary outcomes included: rate and time to diagnosis of postoperative intraperitoneal collections; rate of surgical site infections (SSIs); time to discharge; and 30-day major postoperative complications (Clavien-Dindo grade at least III). After propensity score matching, multivariable logistic regression and Cox proportional hazards regression were used to estimate the independent association of the secondary outcomes with drain placement. Results Overall, 1805 patients from 22 countries were included (798 women, 44.2 per cent; median age 67.0 years). The drain insertion rate was 51.9 per cent (937 patients). After matching, drains were not associated with reduced rates (odds ratio (OR) 1.33, 95 per cent c.i. 0.79 to 2.23; P = 0.287) or earlier detection (hazard ratio (HR) 0.87, 0.33 to 2.31; P = 0.780) of collections. Although not associated with worse major postoperative complications (OR 1.09, 0.68 to 1.75; P = 0.709), drains were associated with delayed hospital discharge (HR 0.58, 0.52 to 0.66; P &lt; 0.001) and an increased risk of SSIs (OR 2.47, 1.50 to 4.05; P &lt; 0.001). Conclusion Intraperitoneal drain placement after elective colorectal surgery is not associated with earlier detection of postoperative collections, but prolongs hospital stay and increases SSI risk

    Global variation in anastomosis and end colostomy formation following left-sided colorectal resection

    Get PDF
    Background End colostomy rates following colorectal resection vary across institutions in high-income settings, being influenced by patient, disease, surgeon and system factors. This study aimed to assess global variation in end colostomy rates after left-sided colorectal resection. Methods This study comprised an analysis of GlobalSurg-1 and -2 international, prospective, observational cohort studies (2014, 2016), including consecutive adult patients undergoing elective or emergency left-sided colorectal resection within discrete 2-week windows. Countries were grouped into high-, middle- and low-income tertiles according to the United Nations Human Development Index (HDI). Factors associated with colostomy formation versus primary anastomosis were explored using a multilevel, multivariable logistic regression model. Results In total, 1635 patients from 242 hospitals in 57 countries undergoing left-sided colorectal resection were included: 113 (6·9 per cent) from low-HDI, 254 (15·5 per cent) from middle-HDI and 1268 (77·6 per cent) from high-HDI countries. There was a higher proportion of patients with perforated disease (57·5, 40·9 and 35·4 per cent; P < 0·001) and subsequent use of end colostomy (52·2, 24·8 and 18·9 per cent; P < 0·001) in low- compared with middle- and high-HDI settings. The association with colostomy use in low-HDI settings persisted (odds ratio (OR) 3·20, 95 per cent c.i. 1·35 to 7·57; P = 0·008) after risk adjustment for malignant disease (OR 2·34, 1·65 to 3·32; P < 0·001), emergency surgery (OR 4·08, 2·73 to 6·10; P < 0·001), time to operation at least 48 h (OR 1·99, 1·28 to 3·09; P = 0·002) and disease perforation (OR 4·00, 2·81 to 5·69; P < 0·001). Conclusion Global differences existed in the proportion of patients receiving end stomas after left-sided colorectal resection based on income, which went beyond case mix alone

    Gas Chromatography-Tandem Mass Spectrometry Method for Selective Detection of 2-Nitropropane in Mainstream Cigarette Smoke

    No full text
    Although 2-nitropropane is a potentially harmful compound present in cigarette smoke, there are few fully-validated, modern methods to quantitate it in mainstream cigarette smoke. We developed an isotope dilution gas chromatography-tandem mass spectrometry (ID-GC-MS/MS) method for the detection of 2-nitropropane in mainstream cigarette smoke. The vapor fraction of mainstream cigarette smoke was collected in inert polyvinyl fluoride gas sampling bags and extracted with hexanes containing isotopically labeled internal standard, then purified and concentrated via solid-phase extraction using a normal phase silica adsorbent and a 100% dichloromethane eluant. This method is sensitive enough to measure vapor phase 2-nitro-propane concentrations in the nanogram range, with a 19 ng per cigarette method limit of detection. Product variability estimated from the analysis of 15 cigarette products yielded relative standard deviations ranging from 5.4% to 15.7%, and estimates of precision from two quality control products yielded relative standard deviations of 9.49% and 14.9%. Under the Health Canada Intense smoking regimen, 2-nitropropane in machine-generated mainstream smoke from 15 cigarette products ranged from 98.3 to 363 ng per cigarette
    corecore