6,553 research outputs found

    Hypertension-induced renal fibrosis and spironolactone response vary by rat strain and mineralocorticoid receptor gene expression

    Get PDF
    Introduction. Aldosterone promotes renal fibrosis via the mineralocorticoid receptor (MR), thus contributing to hypertension-induced nephropathy. We investigated whether MR gene expression influences renal fibrosis and MR antagonist response in a two-kidney, one-clip hypertensive rat model. Materials and methods. Brown Norway (BN), Lewis, and ACI rats were randomised to spironolactone 20 mg/kg/day or water by gavage, starting four weeks after left renal artery clipping. Blood pressure was measured bi-weekly by tail cuff. After eight weeks of treatment, right kidneys were removed and examined for fibrosis and gene expression. Rats of each strain undergoing no intervention served as controls. Results. Blood pressure increased similarly among strains after clipping and was unaffected by spironolactone. Hypertension caused the greatest renal fibrosis in BN rats (p \u3c 0.001 by ANOVA compared to other strains). Real-time PCR analysis showed greater renal collagen type I and MR gene expression in untreated, hypertensive BN rats (both p \u3c 0.05 compared to other strains). Spironolactone attenuated fibrosis, with similar fibrosis among strains of spironolactone-treated rats. Conclusion. Hypertension-induced renal fibrosis was greatest in rats with the highest MR gene expression. Spironolactone abolished inter-strain differences in fibrosis. Our data suggest that MR genotype may influence aldosterone-induced renal damage, and consequently, renal response to aldosterone antagonism

    Aplicaçþes preventivas de inseticidas intensificam o ataque do percevejo-marrom Euschistus heros em soja.

    Get PDF
    Objetivo: avaliar o efeito do manejo de pragas com aplicaçþes preventivas de inseticidas para lagartas e percevejos sobre a densidade populacional de E. heros no início da fase crítica de dano desta praga a soja

    Response of microchannel plates to single particles and to electromagnetic showers

    Get PDF
    We report on the response of microchannel plates (MCPs) to single relativistic particles and to electromagnetic showers. Particle detection by means of secondary emission of electrons at the MCP surface has long been proposed and is used extensively in ion time-of-flight mass spectrometers. What has not been investigated in depth is their use to detect the ionizing component of showers. The time resolution of MCPs exceeds anything that has been previously used in calorimeters and, if exploited effectively, could aid in the event reconstruction at high luminosity colliders. Several prototypes of photodetectors with the amplification stage based on MCPs were exposed to cosmic rays and to 491 MeV electrons at the INFN-LNF Beam-Test Facility. The time resolution and the efficiency of the MCPs are measured as a function of the particle multiplicity, and the results used to model the response to high-energy showers.Comment: Paper submitted to NIM

    Response of microchannel plates in ionization mode to single particles and electromagnetic showers

    Full text link
    Hundreds of concurrent collisions per bunch crossing are expected at future hadron colliders. Precision timing calorimetry has been advocated as a way to mitigate the pileup effects and, thanks to their excellent time resolution, microchannel plates (MCPs) are good candidate detectors for this goal. We report on the response of MCPs, used as secondary emission detectors, to single relativistic particles and to electromagnetic showers. Several prototypes, with different geometries and characteristics, were exposed to particle beams at the INFN-LNF Beam Test Facility and at CERN. Their time resolution and efficiency are measured for single particles and as a function of the multiplicity of particles. Efficiencies between 50% and 90% to single relativistic particles are reached, and up to 100% in presence of a large number of particles. Time resolutions between 20ps and 30ps are obtained.Comment: 20 pages, 9 figures. Paper submitted to NIM

    Performance of a Tungsten-Cerium Fluoride Sampling Calorimeter in High-Energy Electron Beam Tests

    Full text link
    A prototype for a sampling calorimeter made out of cerium fluoride crystals interleaved with tungsten plates, and read out by wavelength-shifting fibres, has been exposed to beams of electrons with energies between 20 and 150 GeV, produced by the CERN Super Proton Synchrotron accelerator complex. The performance of the prototype is presented and compared to that of a Geant4 simulation of the apparatus. Particular emphasis is given to the response uniformity across the channel front face, and to the prototype's energy resolution.Comment: 6 pages, 6 figures, Submitted to NIM

    Status of the LHC Superconducting Cable Mass Production

    Get PDF
    Six contracts have been placed with industrial companies for the production of 1200 tons of the superconducting (SC) cables needed for the main dipoles and quadrupoles of the Large Hadron Collider (LHC). In addition, two contracts have been placed for the supply of 470 tons of NbTi and 26 tons of Nb sheets. The main characteristic of the specification is that it is functional. This means that the physical, mechanical and electrical properties of strands and cables are specified without defining the manufacturing processes. Facilities for the high precision measurements of the wire and cable properties have been implemented at CERN, such as strand and cable critical current, copper to superconductor ratio, interstrand resistance, magnetisation, RRR at 4.2 K and 1.9 K. The production has started showing that the highly demanding specifications can be fulfilled. This paper reviews the organisation of the contracts, the test facilities installed at CERN, the various types of measurements and the results of the main physical properties obtained on the first batches. The status of the deliveries is presented

    Implementation and performance of the Detector Control System for the electromagnetic calorimeter of the CMS experiment

    Get PDF
    In this presentation we describe the main design objectives, the detailed specifications and the final layout of the Detector Control System (DCS) for the electromagnetic calorimeter (ECAL) of the CMS experiment. Emphasis is put on the system implementation and specific hardware and software solutions in each of its sub-systems. The latest results from the tests of final prototypes of these subsystems during the 2006 ECAL test-beam programme, as well as the installation and commissioning of the whole DCS at the CMS experimental construction site are discussed

    Altered Rest-Activity Patterns Evolve via Circadian Independent Mechanisms in Cave Adapted Balitorid Loaches

    Get PDF
    Circadian rhythms and rest homeostasis are independent processes, each regulating important components of rest-activity patterns. Evolutionarily, the two are distinct from one another; total rest time is maintained unaffected even when circadian pacemaker cells are ablated. Throughout the animal kingdom, there exists a huge variation in rest-activity patterns, yet it is unclear how these behaviors have evolved. Here we show that four species of balitorid cavefish have greatly reduced rest times in comparison to rest times of their surface relatives. All four cave species retained biological rhythmicity, and in three of the four there is a pronounced 24-hour rhythm; in the fourth there is an altered rhythmicity of 38–40 hours. Thus, consistent changes in total rest have evolved in these species independent of circadian rhythmicity. Taken together, our data suggest that consistent reduction in total rest times were accomplished evolutionarily through alterations in rest homeostasis

    Detector Control System for the Electromagnetic Calorimeter of the CMS experiment

    Get PDF
    The Compact Muon Solenoid (CMS) is one of the general purpose particle detectors at the Large Hadron Collider (LHC) at CERN. The challenging constraints on the design of one of its sub-detectors, the Electromagnetic Calorimeter (ECAL), required the development of a complex Detector Control System (DCS). In this paper the general features of the CMS ECAL DCS during the period of commissioning and cosmic running will be presented. The feedback from the people involved was used for several upgrades of the system in order to achieve a robust, flexible and stable control system. A description of the newly implemented features for the CMS ECAL DCS subsystems will be given as well

    Standalone vertex nding in the ATLAS muon spectrometer

    Get PDF
    A dedicated reconstruction algorithm to find decay vertices in the ATLAS muon spectrometer is presented. The algorithm searches the region just upstream of or inside the muon spectrometer volume for multi-particle vertices that originate from the decay of particles with long decay paths. The performance of the algorithm is evaluated using both a sample of simulated Higgs boson events, in which the Higgs boson decays to long-lived neutral particles that in turn decay to bbar b final states, and pp collision data at √s = 7 TeV collected with the ATLAS detector at the LHC during 2011
    • …
    corecore