203 research outputs found

    Effect of gold coating on sensitivity of rhombic silver nanostructure array

    Get PDF
    The sensitivity is the most important parameter in the sensing field. Effort was made to study the effect of gold coating on the sensitivity of rhombic silver nanostructure array through numerical simulation using the discrete dipole approximation method. This study shows that thickness of the gold coating can be varied to tune the sensitivity of the rhombic silver nanostructure array. The Au-Ag nanostructure array is found to possess the maximum refractive index sensitivity of 714 nm/RIU when thickness of gold is 20 nm, thickness of silver is 25 nm, and refractive index of the medium is around 1.35. The condition for achieving the maximum refractive index sensitivity can be used for detecting many species of biomolecules and drugs in the future

    Magnetic resonance imaging protocols for paediatric neuroradiology

    Get PDF
    Increasingly, radiologists are encouraged to have protocols for all imaging studies and to include imaging guidelines in care pathways set up by the referring clinicians. This is particularly advantageous in MRI where magnet time is limited and a radiologist’s review of each patient’s images often results in additional sequences and longer scanning times without the advantage of improvement in diagnostic ability. The difficulties of imaging small children and the challenges presented to the radiologist as the brain develops are discussed. We present our protocols for imaging the brain and spine of children based on 20 years experience of paediatric neurological MRI. The protocols are adapted to suit children under the age of 2 years, small body parts and paediatric clinical scenarios

    Extraction and sensitive detection of toxins A and B from the human pathogen Clostridium difficile in 40 seconds using microwave-accelerated metal-enhanced fluorescence.

    Get PDF
    Clostridium difficile is the primary cause of antibiotic associated diarrhea in humans and is a significant cause of morbidity and mortality. Thus the rapid and accurate identification of this pathogen in clinical samples, such as feces, is a key step in reducing the devastating impact of this disease. The bacterium produces two toxins, A and B, which are thought to be responsible for the majority of the pathology associated with the disease, although the relative contribution of each is currently a subject of debate. For this reason we have developed a rapid detection assay based on microwave-accelerated metal-enhanced fluorescence which is capable of detecting the presence of 10 bacteria in unprocessed human feces within 40 seconds. These promising results suggest that this prototype biosensor has the potential to be developed into a rapid, point of care, real time diagnostic assay for C. difficile

    Sensitivity of MEG and EEG to Source Orientation

    Get PDF
    An important difference between magnetoencephalography (MEG) and electroencephalography (EEG) is that MEG is insensitive to radially oriented sources. We quantified computationally the dependency of MEG and EEG on the source orientation using a forward model with realistic tissue boundaries. Similar to the simpler case of a spherical head model, in which MEG cannot see radial sources at all, for most cortical locations there was a source orientation to which MEG was insensitive. The median value for the ratio of the signal magnitude for the source orientation of the lowest and the highest sensitivity was 0.06 for MEG and 0.63 for EEG. The difference in the sensitivity to the source orientation is expected to contribute to systematic differences in the signal-to-noise ratio between MEG and EEG.National Institutes of Health (U.S.) (Grant NS057500)National Institutes of Health (U.S.) (Grant NS037462)National Institutes of Health (U.S.) (Grant HD040712)National Center for Research Resources (U.S.) (P41RR14075)Mind Research Networ

    Persistence and compliance to antidepressant treatment in patients with depression: A chart review

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Adherence has recently been suggested to be divided into these two components: persistence (i.e., whether patients continue treatment or not) and compliance (i.e., whether patients take doses as instructed). However, no study has yet assessed these two clinically relevant components at the same time in adherence to antidepressant treatment in the clinical outpatient setting.</p> <p>Methods</p> <p>In this retrospective chart-review, 6-month adherence to antidepressants was examined in 367 outpatients with a major depressive disorder (ICD-10) (170 males; mean ± SD age 37.6 ± 13.9 years), who started antidepressant treatment from April 2006 through March 2007. Additionally, we evaluated Medication Possession Rate (MPR), defined as the total days a medication was dispensed to patients divided by the treatment period.</p> <p>Results</p> <p>Only 161 patients (44.3%) continued antidepressant treatment for 6 months. Among 252 patients who discontinued their initial antidepressant, 63.1% of these patients did so without consulting their physicians. Sertraline use was associated with a higher persistence rate at month 6 (odds ratio 2.59 in comparison with sulpiride), and the use of anxiolytic benzodiazepines had a positive effect on persistence to antidepressant treatment only at month 1 (odds ratio 2.14). An overall MPR was 0.77; 55.6% of patients were considered compliant (i.e., a MPR of ≥ 0.8).</p> <p>Conclusion</p> <p>Given a high rate of antidepressant discontinuation without consulting their physicians, closer communication between patients and their physicians should be encouraged. Although the use of anxiolytic benzodiazepines was associated with a higher persistence to antidepressant treatment at month 1, the use of these drugs should be avoided as a rule, given their well-known serious adverse effects.</p

    The mediating role of discrete emotions in the relationship between injustice and counterproductive work behaviors:a study in Pakistan

    Get PDF
    Purpose: Our study explores the mediating role of discrete emotions in the relationships between employee perceptions of distributive and procedural injustice, regarding an annual salary raise, and counterproductive work behaviors (CWBs). Design/Methodology/Approach: Survey data were provided by 508 individuals from telecom and IT companies in Pakistan. Confirmatory factor analysis, structural equation modeling, and bootstrapping were used to test our hypothesized model. Findings: We found a good fit between the data and our tested model. As predicted, anger (and not sadness) was positively related to aggressive CWBs (abuse against others and production deviance) and fully mediated the relationship between perceived distributive injustice and these CWBs. Against predictions, however, neither sadness nor anger was significantly related to employee withdrawal. Implications: Our findings provide organizations with an insight into the emotional consequences of unfair HR policies, and the potential implications for CWBs. Such knowledge may help employers to develop training and counseling interventions that support the effective management of emotions at work. Our findings are particularly salient for national and multinational organizations in Pakistan. Originality/Value: This is one of the first studies to provide empirical support for the relationships between in/justice, discrete emotions and CWBs in a non-Western (Pakistani) context. Our study also provides new evidence for the differential effects of outward/inward emotions on aggressive/passive CWBs

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns
    corecore